- Siemens
- ABB
-
A-B
- MTL
- Pepperl Fuchs
- Phoenix
- Weidmuller
-
IFM
-
Hirschman
-
Hach
-
Schneider
- Norgren
- Fluke
- Sick
- Moxa
- Honeywell
- Yokogawa
- Rosemount
- Emerson
- Beamex
- Festo
- Oring
- Danfoss
- Rotork YTC
- Atlas Copco
-
Allen Bradley
-
YASKAWA
- Triconex
-
Endress+Hauser
-
Dungs
- Belimo
-
Jaquet
-
WIKA
-
UE
- Foxboro
- SMC
-
bifold
-
Nagano Keiki
-
AIRTAC
-
Dynisco
-
proface
-
Woodward
-
CPC
-
Durag
-
Crowcon
-
Bently Nevada
- Krohne
- York
- Bray
-
B&R
- MSA
- AZBIL
- Omron
-
PEPPER+FUCHS
-
MEANWELL
- GE
- XECRO
-
KONAN
-
Fairford
-
testo
-
Emotron
- PR electronics
MTL Surge Protection Safeguards electronic process transmitters MTL TP48 range
MTL Surge Protection Safeguards electronic process transmitters MTL TP48 range
MTL Surge Protection Safeguards electronic process transmitters MTL TP48 range
MTL Surge Protection Safeguards electronic process transmitters MTL TP48 range
Description
•Protects 2, 3 and 4 wire transmitters
•Easy and direct mounting — screws into spare conduit entry
•Intrinsically safe and flameproof to CENELEC standards
•Parallel connection avoids introduction of any resistance into loop
•ATEX approved
MTL Surge Protection Safeguards electronic process transmitters MTL TP48 range
Specification
Maximum surge current 20kA peak current (8/20µs waveform)
Leakage current
Less than 10µA at max. working voltage
Working voltage
35V dc maximum
Bandwidth
1MHz
Resistance
No resistance introduced into loop
Ambient temperature limits
-40°C to +85°C
(-40°F to +185°F) (working)
-40°C to +85°C
(-40°F to +185°F) (storage)
Humidity
5% to 95% RH (non-condensing)
Electrical connections
TP48
3flying leads (line1, line 2 & earth) TP48 3 Wire
4flying leads (+ve, -ve, signal & earth)
TP48 4 Wire
5flying leads (+ve, -ve, signal +ve, signal -ve, earth)
Wire size: 32/0.2 (1.0mm2, 18 AWG) Lead length: 250mm (minimum)
Casing
316 stainless steel suitable for harsh environments
Threads
TP48-3-N & TP48-4-N - 1/2” NPT TP48-3-I & TP48-4-1 - 20mm ISO ) (M20 x 1.5)
TP48-3-G & TP48-4-G - G 1/2” (BSP 1/2”)
Weight
175g. (6.2oz.)
EMC compliance
To Generic Immunity Standards
BS EN 61326-1:2013 for industrial environments
Hazardous Area
Ex ia IIC T4, Ceq=O, Leq=0; the unit can be connected without further certification into any intrinsically safe loop with open circuit voltage <60V and
input power <1.2W.
Ex d IIC T4; the unit is apparatus approved to flameproof (explosion- proof) standards, and can be fitted into a similarly approved housing.
Electrical Safety
To BS EN 61643-21:2001 for surge protection devices
MTL Surge Protection Safeguards electronic process transmitters MTL TP48 range
TP48-N Non-certified SPD- 1/2” NPT thread TP48-N-NDI Certified SPD- 1/2” NPT thread
TP48-I Non-certified SPD- 20mm ISO thread TP48-I-NDI Certified SPD- 20mm ISO thread
TP48-G Non-certified SPD- G 1/2” (BSP 1/2 inch) TP48-G-NDI Certified SPD- G 1/2” (BSP 1/2 inch)
TP48-3-N Non-certified SPD- 1/2” NPT thread TP48-3-N-NDI Certified SPD- 1/2” NPT thread
TP48-3-I Non-certified SPD- 20mm ISO thread TP48-3-I-NDI Certified SPD- 20mm ISO thread
TP48-3-G Non-certified SPD- G 1/2” BSP 1/2 inch TP48-3-G-NDI Certified SPD- 20mm ISO thread
TP48-4-N Non-certified SPD- 1/2” NPT thread TP48-4-N-NDI Certified SPD- 1/2” NPT thread
TP48-4-I Non-certified SPD- 20mm ISO thread TP48-4-I-NDI Certified SPD- 20mm ISO thread
TP48-4-G Non-certified SPD- G 1/2” BSP 1/2 inch TP48-4-G-NDI Certified SPD- G 1/2”- BSP 1/2 inch