-
Siemens
-
Siemens Siprotec 7SK...
-
Siemens Siprotec 7UT...
-
Siemens Siprotec 7SL...
-
Siemens Siprotec 7SA...
-
Siemens Siprotec 7SD...
-
Siemens Simatic ET 2...
-
Siemens Siprotec 7SJ...
-
Siemens Power Contac...
-
Siemens Temperature ...
-
Siemens spare parts
-
Siemens motors
-
Siemens Positioner
-
Siemens Drives
-
Siemens PLC
-
Siemens Transmitter
-
Siemens Siprotec 7SK...
- Yokogawa
- Phoenix
- Hirschman
- Honeywell
- ABB
- MTL
- Pepperl Fuchs
-
Schneider
- Emerson
- Weidmuller
- Moxa
- Endress+Hauser
-
Allen Bradley
-
Mitsubishi
-
IFM
-
SEW
-
Hach
- Norgren
- Fluke
- Danfoss
- Sick
-
A-B
- Rosemount
- Beamex
- Festo
- Oring
- Rotork YTC
- Atlas Copco
-
YASKAWA
- Triconex
-
Dungs
- Belimo
-
Jaquet
-
WIKA
-
UE
- Foxboro
- SMC
-
bifold
-
Nagano Keiki
-
AIRTAC
-
Dynisco
-
proface
-
Woodward
-
WAGO
-
CPC
-
PILZ
-
Durag
-
VEICHI
- Krohne
- York
- Bray
-
B&R
- MSA
- AZBIL
- Omron
-
PEPPER+FUCHS
-
MEANWELL
-
Crowcon
- GE
- XECRO
-
KONAN
-
Fairford
-
testo
-
Bently Nevada
-
Emotron
- PR electronics
容器组件
Massive Arrival of Schneider Electric ComPacT NSX & TeSys Control Series
日期:2026-08-31 14:42
浏览次数:35
摘要:The newly arrived inventory includes hot-selling models such as C10B3TM016, C10H3, C10F3TM050, and C16N3D100. The ComPacT NSX range is universally acclaimed for its robust electrical distribution protection, advanced thermal-magnetic trip units, and integrated energy monitoring features.o power and secure intensive industrial motor operations, we have restocked a comprehensive lineup of TeSys Giga contactors, prominently featuring large-frame models like LC1G205LSEC and LC1G185LSEA
Massive Arrival of Schneider Electric ComPacT NSX & TeSys Control Series

HONG KONG, Aug 17, 2026 – HONGKONG XIEYUAN TECH CO., LIMITED is thrilled to announce the successful arrival of a large shipment of premium Schneider Electric low-voltage automation and control products at our Hong Kong warehouse today. As a trusted global industrial supplier, we continue to reinforce our strong supply capabilities to meet the high demand of our global clients.
This new inventory primarily highlights two iconic Schneider Electric product ranges:
1. ComPacT NSX Series Molded Case Circuit Breakers (MCCB)
The newly arrived inventory includes hot-selling models such as C10B3TM016, C10H3, C10F3TM050, and C16N3D100. The ComPacT NSX range is universally acclaimed for its robust electrical distribution protection, advanced thermal-magnetic trip units, and integrated energy monitoring features.
-
Other Representative Models Available: We also support extended framework models including NSX100N, NSX160S, NSX250F, NSX400H, and NSX630N.
2. TeSys Control / TeSys Giga Series High-Power Contactors
To power and secure intensive industrial motor operations, we have restocked a comprehensive lineup of TeSys Giga contactors, prominently featuring large-frame models like LC1G205LSEC and LC1G185LSEA from the shipment. These contactors boast wide-band AC/DC coils (200-500V) and on-site wear diagnosis capabilities to maximize machinery uptime.
- Other Representative Models Available: Clients can also place orders for LC1G115LSEN, LC1G2254LSEA, LC1G400KUEN, and LC1G500EHEN.
All products arrived in their original factory-sealed packaging, ready for rapid dispatch across Asia and worldwide.
Secure Your Order Today:
For tailored quotes, datasheets, or instant inventory checks, please contact our dedicated sales representative:
For tailored quotes, datasheets, or instant inventory checks, please contact our dedicated sales representative:
- Contact Person: Jessica
- Email: sales1@hkxytech.com
- Phone/WhatsApp: +86-15871691193
- Official Websites: www.hkxytech.com & http://www.xy-control.com/
QAS
Q1: What are the key differences between ComPacT NSX "B", "F", "N", "H" designations found in models like C10B3 or C16N3?
A1: These letter indicators stand for the Breaking Capacity Levels (\(I_{cu}\) at 380/415V AC) of the circuit breaker. For instance, "B" represents standard commercial breaking capacity (25 kA), "F" represents 36 kA, "N" represents a higher industrial standard (50 kA), and "H" is designed for heavy-duty environments or high-fault current sites (70 kA or above). Matching these to your specific transformer fault calculation prevents critical control panel failure.
A1: These letter indicators stand for the Breaking Capacity Levels (\(I_{cu}\) at 380/415V AC) of the circuit breaker. For instance, "B" represents standard commercial breaking capacity (25 kA), "F" represents 36 kA, "N" represents a higher industrial standard (50 kA), and "H" is designed for heavy-duty environments or high-fault current sites (70 kA or above). Matching these to your specific transformer fault calculation prevents critical control panel failure.
Q2: What advantages do the TeSys Giga LC1G contactors (like LC1G205 / LC1G185) have over older series?
A2: The TeSys Giga series directly replaces the legacy LC1F range. Key upgrades include:
A2: The TeSys Giga series directly replaces the legacy LC1F range. Key upgrades include:
- Electronic Wide-Band Coils: A single coil code (e.g., LSEN or LSEA) operates reliably across a wide voltage tolerance (such as 200V to 500V AC/DC), reducing necessary spare parts inventory.
- Contact Wear Diagnostics (CWD): Built-in indicators continuously monitor contact condition, shifting maintenance from reactive troubleshooting to smart predictive care.
Q3: Can the electronic trip units on ComPacT NSX circuit breakers be upgraded or modified after installation?
A3: Yes. One of the core engineering benefits of the Schneider ComPacT NSX platform is its modular, interchangeable trip unit architecture. You can upgrade basic thermal-magnetic units (TM-D) to advanced Micrologic electronic units (e.g., Micrologic 2.2 or 5.2) right on site without unmounting the breaker frame from your electrical busbar panel.
A3: Yes. One of the core engineering benefits of the Schneider ComPacT NSX platform is its modular, interchangeable trip unit architecture. You can upgrade basic thermal-magnetic units (TM-D) to advanced Micrologic electronic units (e.g., Micrologic 2.2 or 5.2) right on site without unmounting the breaker frame from your electrical busbar panel.