Current Location: Home> Product Class> MTL> MTL4500>

MTL4516 safety barrier 2channel DI relay output MTL4500 isolated barrier

  • Product Name:MTL4516 safety barrier 2channel DI relay output MTL4500 isolated barrier
  • Product Number:MTL4516
  • Brand:MTL
  • Views:213
你添加了1件商品 查看购物车
简单介绍
MTL4516 safety barrier 2channel DI relay output MTL4500 isolated barrier MTL4516 safety barrier 2channel DI relay output MTL4500 isolated barrier MTL4516 safety barrier 2channel DI relay output MTL4500 isolated barrier

MTL4516 safety barrier 2channel DI relay output MTL4500 isolated barrier

的详细介绍

Product overview

MTL4516 safety barrier 2channel DI relay output MTL4500 isolated barrier



                MTL4516 safety barrier  2 channel  DI relay output MTL4500 isolated barrier

                               

MTL4516 product specification as below

MTL4516 safety barrier 2channel DI relay output MTL4500 isolated barrier

MTL4516/C – MTL5516C SWITCH/ PROXIMITY DETECTOR INTERFACE 2-channel, with line fault detection The MTLx516/C enable two safe-area loads to be controlled by a switch or proximity detector located in a hazardous-area. When selected, open or short circuit conditions in the field wiring are detected by the linefault-detect (LFD) facility and also indicated on the top of the module. Phase reversal for each channel is selected by a switch on the side of the module and output is provided by changeover relay contacts.

MTL4516 safety barrier 2channel DI relay output MTL4500 isolated barrier

SPECIFICATION

See also common specification

Number of channels

Two

Location of switches

Zone 0, IIC, T6 hazardous area

Div. 1, Group A hazardous location

Location of proximity detector

Zone 0, IIC, T4–6 hazardous area if suitably certified

Div. 1, Group A hazardous location

Hazardous-area inputs

Inputs conforming to BS EN60947–5–6:2001 standards for

proximity detectors (NAMUR)

Voltage applied to sensor

7 to 9V dc from 1kΩ ±10%

Input/output characteristics

Normal phase

Outputs closed if input > 2.1mA (< 2kΩ in input circuit)

Outputs open if input < 1.2mA (> 10kΩ in input circuit)

Hysteresis: 200µA (650Ω) nominal

Line fault detection (LFD) (when selected)

User-selectable via switches on the side of the unit. Line faults are

indicated by an LED for each channel. The channel output relay is

de-energised if an input line fault is detected.

Open-circuit alarm on if Iin < 50µA

Open-circuit alarm off if Iin > 250µA

Short-circuit alarm on if Rin < 100Ω

Short-circuit alarm off if Rin > 360Ω

Note: Resistors must be fitted when using the LFD facility with a contact input

500Ω to 1kΩ in series with switch

20kΩ to 25kΩ in parallel with switch

Safe-area output

Two single-pole relays with changeover contacts

Note: reactive loads must be adequately suppressed

Maximum current consumption

35mA at 24V

Power dissipation within unit

0.84W at 24V

LED indicators

Green: power indication

Yellow: two: channel status, on when output energised

Red: two: LFD indication, on when line fault detected

Safety description (each channel)

Uo=10.5V Io=14mA Po=37mW Um = 253V rms or dc

MTL4516 safety barrier 2channel DI relay output MTL4500 isolated barrier

Other related models for MTL4500 ranges as below


MTL4501-SR       

MTL4504                

MTL4510              

MTL4510B                

MTL4511

MTL4513             

MTL4514D             

MTL4514_B          

MTL4516                   

MTL4516C

MTL4517             

MTL4521                

MTL4521L            

MTL4523                  

MTL4523L

MTL4523R           

MTL4523V-VL        

MTL4524              

MTL4524S                

MTL4525  

MTL4526             

MTL4541                

MTL4541A            

MTL4541AS              

MTL4541B

MTL4541P           

MTL4541S              

MTL4541T            

MTL4544                  

MTL4544A

MTL4544AS         

MTL4544B               

MTL4544D           

MTL4544S                 

MTL4546

MTL4546C           

MTL4546S              

MTL4546Y            

MTL4549                  

MTL4549C

MTL4549Y           

MTL4573                

MTL4575              

MTL4576-RTD           

MTL4576-THC

MTL4581             

MTL4582B              

MTL4531              

MTL4532                   

MTL4561

MTL4599             

MTL4599N

MTL4516 safety barrier 2channel DI relay output MTL4500 isolated barrier


If you have any other question, please be free to contact me here!

Contact details

HONGKONG XIEYUAN TECH CO., LIMITED

Telephone:86-027-85508558

Mobile :86-15871691193(Whatapp&Wechat is available)

Skype:xyautomation

E-mail:sales1@hkxytech.com

 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd