REPEATER POWER SUPPLY 4/20mA, HART庐, for 2- or 3-wire transmitters
	The MTL4541B
provides a fully-floating dc supply for energising a conventional 2- or 3-wire
4/20mA transmitter which is located in a hazardous area, and repeats the
current in another circuit to drive a safe-area load. For HART 2-wire
transmitters, the unit allows bi-directional communications signals
superimposed on the 4/20mA loop current.
	SPECIFICATION
	MTL4541B MTL4041B replacement isolated barrier England origin
	See also common
specification
	Number of
channels
	One
	Location of
transmitter
	Zone 0, IIC,
T4–6 hazardous area if suitably certified
	Div. 1, Group A
hazardous location
	Safe-area
output
	Signal range: 4
to 20mA
	Under/over-range:
0 to 24mA
	Safe-area load
resistance: 0 to 360Ω @ 24mA
	0 to 450Ω @
20mA
	Safe-area
circuit output resistance: > 1MΩ
	Safe-area
circuit ripple
	<50µA
peak-to-peak
	Hazardous-area
input
	Signal range: 0
to 24mA (including over-range)
	Transmitter
voltage: 16.5V at 20mA
	Transfer
accuracy at 20°C
	Better than
15µA
	Temperature
drift
	< 0.8µA/°C
	Response time
	Settles to
within 10% of final value within 50µs
	Communications
supported
	HART (terminals
1 & 2 only)
	LED indicator
	Green: power
indication
	Maximum current
consumption (with 20mA signal)
	51mA at 24V
	Power
dissipation within unit (with 20mA signal)
	0.7W at 24V
	Safety
description
	Terminals 2 to
1 and 3:
	Vo=28V Io=93mA
Po=651mW Um = 253V rms or dc
	Terminals 1 to
3:
	Simple
apparatus ≤1.5V, ≤0.1A and ≤25mW; can be connected
	without further
certification into any IS loop with an open-circuit
	voltage <28V
	
Other related models for MTL4500 range as below
	MTL4541B MTL4041B replacement isolated barrier England origin
	MTL4501-SR        
	MTL4504                 
	MTL4510               
	MTL4510B                 
	MTL4511
	MTL4513              
	MTL4514D              
	MTL4514_B           
	MTL4516                    
	MTL4516C
	MTL4517              
	MTL4521                 
	MTL4521L             
	MTL4523                   
	MTL4523L
	MTL4523R            
	MTL4523V-VL         
	MTL4524               
	MTL4524S                 
	MTL4525   
	MTL4526              
	MTL4541                 
	MTL4541A             
	MTL4541AS               
	MTL4541B
	MTL4541P            
	MTL4541S               
	MTL4541T             
	MTL4544                   
	MTL4544A
	MTL4544AS          
	MTL4544B               
	MTL4544D            
	MTL4544S                  
	MTL4546
	MTL4546C            
	MTL4546S               
	MTL4546Y             
	MTL4549                   
	MTL4549C
	MTL4549Y            
	MTL4573                 
	MTL4575               
	MTL4576-RTD            
	MTL4576-THC
	MTL4581              
	MTL4582B               
	MTL4531               
	MTL4532                    
	MTL4561
	MTL4599              
MTL4541B MTL4041B replacement isolated barrier England origin
	
 
If you have any other question abut MTL4541B, please feel free to contact me here!
Contact details
	HONGKONG XIEYUAN TECH CO., LIMITED
	Telephone:86-027-85508558
Mobile :86-15871691193(Whatapp&Wechat is available)
	Skype:xyautomation
	
 
     
     
                             
                             
                             
                             
                             
                             
                             
                             
                            