MTL4544B MTL4044 replacement original isolated barrier
- Product Name:MTL4544B MTL4044 replacement original isolated barrier
- Product Number:MTL4544B
- Brand:MTL
- Views:241
- 
                    
                         
MTL4544B MTL4044 replacement original isolated barrier
的详细介绍Product overview
	MTL4544B MTL4044 replacement original isolated barrier
	
MTL4544B MTL4044 replacement original isolated barrier
	             
 
MTL4544B product specification as below
	MTL4544B MTL4044 replacement original isolated barrier
	MTL4544B
REPEATER POWER SUPPLY 2-channel, 4/20mA, HART庐, 2- or 3-wire transmitters The MTL4544B provides
fully-floating dc supplies for energising two conventional 2- or 3-wire 4/20mA
or HART transmitters located in a hazardous area, and repeats the current in
other circuits to drive two safe-area loads. For HART transmitters, the unit
allows bi-directional transmission of digital communication signals
superimposed on the 4/20mA signal so that the transmitter can be interrogated
either from the operator station or by a hand-held communicator.
	SPECIFICATION
	MTL4544B MTL4044 replacement original isolated barrier
	See also common
specification
	Number of
channels
	Two
	Location of
transmitter
	Zone 0, IIC,
T4-6, hazardous area if suitably certified
	Div 1, Group A,
hazardous location
	Safe-area
output
	Signal range: 4
to 20mA
	Under/over-range:
0 to 24mA
	Safe-area load
resistance: 0 to 360Ω @ 24mA
	0 to 450Ω @
20mA
	Safe-area
circuit output resistance: > 1MΩ
	Safe-area
circuit ripple
	< 50µA
peak-to-peak
	Hazardous-area
input
	Signal range: 0
to 24mA (including over-range)
	Transmitter
voltage: 16.5V at 20mA
	Transfer
accuracy at 20°C
	Better than
20µA
	Temperature
drift
	< 0.8µA/°C
	Response time
	Settles to
within 10% of final value within 50µs
	Communications
supported
	HART®
(terminals 1 & 2 and 4 & 5 only
	LED indicator
	Green: power
indication
	Maximum current
consumption (with 20mA signals)
	96mA at 24V dc
	Power
dissipation within unit (with 20mA signals)
	1.4W at 24V dc
	Safety
description (each channel)
	Terminals 2 to
1 and 3, and 5 to 4 and 6:
	Vo=28V Io=93mA
Po=651mW Um = 253V rms or dc
	Terminals 1 to
3 and 4 to 6:
	Simple
apparatus ≤1.5V, ≤0.1A and ≤25mW; can be connected
	without further
certification into any IS loop with an open-circuit
	voltage <28V 
	
Other related models for MTL4500 range as below
	MTL4544B MTL4044 replacement original isolated barrier
	MTL4501-SR        
	MTL4504                 
	MTL4510               
	MTL4510B                 
	MTL4511
	MTL4513              
	MTL4514D              
	MTL4514_B           
	MTL4516                    
	MTL4516C
	MTL4517              
	MTL4521                 
	MTL4521L             
	MTL4523                   
	MTL4523L
	MTL4523R            
	MTL4523V-VL         
	MTL4524               
	MTL4524S                 
	MTL4525   
	MTL4526              
	MTL4541                 
	MTL4541A             
	MTL4541AS               
	MTL4541B
	MTL4541P            
	MTL4541S               
	MTL4541T             
	MTL4544                   
	MTL4544A
	MTL4544AS          
	MTL4544B               
	MTL4544D            
	MTL4544S                  
	MTL4546
	MTL4546C            
	MTL4546S               
	MTL4546Y             
	MTL4549                   
	MTL4549C
	MTL4549Y            
	MTL4573                 
	MTL4575               
	MTL4576-RTD            
	MTL4576-THC
	MTL4581              
	MTL4582B               
	MTL4531               
	MTL4532                    
	MTL4561
	MTL4599              
	MTL4599N
	MTL4544B MTL4044 replacement original isolated barrier
	
Contact details
	HONGKONG XIEYUAN TECH CO., LIMITED
	Telephone:86-027-85508558
	Mobile :86-15871691193(Whatapp&Wechat
is available)
Skype:xyautomation
E-mail:sales1@hkxytech.com
	
 
     
     
                             
                             
                             
                             
                             
                             
                             
                             
                            