MTL4576-RTD safe barrier 2 channel Temperature converter, RTD
- Product Name:MTL4576-RTD safe barrier 2 channel Temperature converter, RTD
- Product Number:MTL4576-RTD
- Brand:MTL
- Views:228
-
MTL4576-RTD safe barrier 2 channel Temperature converter, RTD
的详细介绍Product overview
MTL4576-RTD safe barrier 2 channel Temperature converter, RTD
MTL4576-RTD safe barrier 2 channel Temperature converter, RTD
MTL4576-RTD product specification as below
MTL4576-RTD safe barrier 2 channel Temperature converter, RTD
MTL4576-RTD –
MTL5576-RTD TEMPERATURE CONVERTER RTD/potentiometer input, 2-channel The
MTLx576–RTD converts signals from resistance temperature detectors (RTDs)
mounted in a hazardous area, into 4/20mA currents for driving safe-area loads.
Software selectable features include input type and characterisation, ranging,
monitoring, testing and tagging. Configuration is carried out using a personal
computer. The MTLx576– RTD is compatible with 2– and 3–wire RTD inputs. The
MTLx576-RTD can also be configured to drive two safe-area loads from a single
input.
SPECIFICATION
MTL4576-RTD safe barrier 2 channel Temperature converter, RTD
See also common
specification
Number of
channels
Two
Signal source
2-/3-wire RTDs
to BS 60751
Pt 100, Pt 500,
Pt 1000
Cu-50 &
Cu-53
Ni 100/500/1000
DIN 43760
Location of
signal source
Zone 0, IIC,
T4–6 hazardous area
Division 1,
Group A, hazardous location
Input signal
range
0 to 400Ω (0 to
4000Ω Pt & Ni sensors)
Input signal
span
10 to 400Ω (10
to 1000Ω Pt & Ni sensors)
RTD excitation
current
200µA nominal
Common mode
rejection
120dB for 240V
at 50Hz or 60Hz
Series mode
rejection
40dB for 50Hz
or 60Hz
Calibration
accuracy (at 20°C)
(includes
hysteresis, non-linearity and repeatability)
Input: ± 80mΩ
Output: ± 16µA
Temperature
drift (typical)
Input: ± 7mΩ/°C
Output: ±
0.6µA/°C
Example of
calibration accuracy and temperature drift
(RTD input)
Span: 250Ω
Accuracy: ± (0.08/250 + 16/16000) x 100
= 0.13% of span
Temperature
drift: ± (0.007/250 x 16000 + 0.6) µA/°C
= ±1.0µA/°C
Safety drive on
sensor failure
Upscale,
downscale, or off
Output range
4 to 20mA
nominal into 300Ω max.
Response time
Configurable -
500 ms default
(Accuracy at
100/200ms - contact MTL)
LED indicator
Green: power
and status indication
Yellow: one
provided for channel status
Red: alarm
indication
Power
requirement, Vs with 20mA signal
60mA at 24V
Power
dissipation within unit with 20mA signal
1.4W at 24V
Isolation
Functional
channel–channel isolation for safe and hazardous–area
circuits
Safety
description
Refer to
certificate for parameters. Um=253V rms or dc
Configurator
A personal
computer running MTL PCS45 software with a
PCL45USB serial
interface.
Other related models for MTL4500 range as below
MTL4576-RTD safe barrier 2 channel Temperature converter, RTD
MTL4501-SR
MTL4504
MTL4510
MTL4510B
MTL4511
MTL4513
MTL4514D
MTL4514_B
MTL4516
MTL4516C
MTL4517
MTL4521
MTL4521L
MTL4523
MTL4523L
MTL4523R
MTL4523V-VL
MTL4524
MTL4524S
MTL4525
MTL4526
MTL4541
MTL4541A
MTL4541AS
MTL4541B
MTL4541P
MTL4541S
MTL4541T
MTL4544
MTL4544A
MTL4544AS
MTL4544B
MTL4544D
MTL4544S
MTL4546
MTL4546C
MTL4546S
MTL4546Y
MTL4549
MTL4549C
MTL4549Y
MTL4573
MTL4575
MTL4576-RTD
MTL4576-THC
MTL4581
MTL4582B
MTL4531
MTL4532
MTL4561
MTL4599
MTL4599N
MTL4576-RTD safe barrier 2 channel Temperature converter, RTD
Contact details
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-027-85508558
Mobile :86-15871691193(Whatapp&Wechat is available)
Skype:xyautomation
E-mail:sales1@hkxytech.com