MTL4561 2channel loop-powered, for fire and smoke detectors
- Product Name:MTL4561 2channel loop-powered, for fire and smoke detectors
- Product Number:MTL4561
- Brand:MTL
- Views:383
- 
                    
                         
MTL4561 2channel loop-powered, for fire and smoke detectors
的详细介绍Product overview
	MTL4561 2channel loop-powered, for fire and smoke detectors
	
MTL4561 2channel loop-powered, for fire and smoke detectors
	                     
 
MTL4561 product specification as below for your reference.
	MTL4561 2channel loop-powered, for fire and smoke detectors
	MTL4561 –
MTL5561 FIRE AND SMOKE DETECTOR INTERFACE 2-channel The MTLx561 is a
loop-powered 2–channel interface for use with conventional fire and smoke
detectors located in hazardous areas. In operation, the triggering of a
detector causes a corresponding change in the safe–area current. The unit
features reverse input polarity protection.
	SPECIFICATION
	MTL4561 2channel loop-powered, for fire and smoke detectors
	See also common
specification
	Number of channels
	Two, fully floating, loop powered
	Location of fire and smoke
detectors
	Zone 0, IIC, T4–6 hazardous area if suitably
certified
	Div. 1, Group A, hazardous area
	Input voltage
	6 to 30V dc
	Current range
	1 to 40mA, nominal
	Quiescent safe–area current
at 20°C
	(hazardous–area terminals open circuit)
	< 400µA at Vin = 24V per channel
	Integral input polarity
protection
	Input circuit protected against reverse polarity
	Minimum output voltage Vout
at 20°C
	For Vin ≤ 25V: Vout = Vin – (0.38 x current in mA)
– 2V
	For Vin > 25V: Vout = 22.5V – (0.35 x current in
mA)
	Maximum output voltage
	28V from 300Ω
	Transfer accuracy at 20°C
	Better than 400µA
	Temperature drift
	< 4µA/°C ( 0°C to 60°C)
	< 15µA/°C (–20°C to 0°C)
	Response time to step input
	Settles to within 5% of final value within 1.5ms
	Power dissipation within
unit
	0.7W maximum at 24V with 40mA signal (each channel)
	0.9W maximum at 30V with 40mA signal (each channel)
	Safety description for each
channel
	Uo=28V Io=93mA Po=0.65W Um = 253V rms or dc
	
Other related models for MTL4500 range as below
	MTL4561 2channel loop-powered, for fire and smoke detectors
	MTL4501-SR        
	MTL4504                 
	MTL4510               
	MTL4510B                 
	MTL4511
	MTL4513              
	MTL4514D              
	MTL4514_B           
	MTL4516                    
	MTL4516C
	MTL4517              
	MTL4521                 
	MTL4521L             
	MTL4523                   
	MTL4523L
	MTL4523R            
	MTL4523V-VL         
	MTL4524               
	MTL4524S                 
	MTL4525   
	MTL4526              
	MTL4541                 
	MTL4541A             
	MTL4541AS               
	MTL4541B
	MTL4541P            
	MTL4541S               
	MTL4541T             
	MTL4544                   
	MTL4544A
	MTL4544AS          
	MTL4544B               
	MTL4544D            
	MTL4544S                  
	MTL4546
	MTL4546C            
	MTL4546S               
	MTL4546Y             
	MTL4549                   
	MTL4549C
	MTL4549Y            
	MTL4573                 
	MTL4575               
	MTL4576-RTD            
	MTL4576-THC
	MTL4581              
	MTL4582B               
	MTL4531               
	MTL4532                    
	MTL4561
MTL4599
MTL4599N
	MTL4561 2channel loop-powered, for fire and smoke detectors
	
	
	
If you have any other question about MTL4561, please feel free to contact me here!
Contact details
	HONGKONG XIEYUAN TECH CO., LIMITED
	Telephone:86-027-85508558
Mobile :86-15871691193(Whatapp&Wechat is available)
	Skype:xyautomation
E-mail:sales1@hkxytech.com
	
 
     
     
                             
                             
                             
                             
                             
                             
                             
                             
                            