MTL4510 SWITCH PROXIMITY DETECTOR INTERFACE
              你添加了1件商品 查看购物车
            
    
            简单介绍
        
        
            MTL4510 SWITCH PROXIMITY DETECTOR INTERFACE
MTL4510 SWITCH PROXIMITY DETECTOR INTERFACE
MTL4510 SWITCH PROXIMITY DETECTOR INTERFACE
        
    MTL4510 SWITCH PROXIMITY DETECTOR INTERFACE
的详细介绍
                            MTL4510 SWITCH PROXIMITY DETECTOR INTERFACE MTL4510
Overview
    Overview
	The MTLx510 enables four solid-state outputs in the safe area to be controlled by up to four switches or proximity detectors located in a hazardous area. Each pair of output transistors shares a common 
	terminal and can switch +ve or –ve polarity signals. A range of module configurations is available (see Table 1) through the use of selector switches. When proximity detector modes are selected, LFD is enabled and the output switches to OFF if a line fault is detected.
MTL4510 SWITCH PROXIMITY DETECTOR INTERFACE MTL4510
	
		
 
	
        MTL4510 SWITCH PROXIMITY DETECTOR INTERFACE MTL4510
		SPECIFICATION 
	
	
		See also common specification 
	
	
		Number of channels 
	
	
		4, configured by switches 
	
	
		Location of switches 
	
	
		Zone 0, IIC, T6 hazardous area 
	
	
		Div 1, Group A hazardous location 
	
	
		Location of proximity detectors 
	
	
		Zone 0, IIC, T4-6 hazardous area if suitably certified 
	
	
		Div 1, Group A, hazardous location 
	
	
		Hazardous-area inputs 
	
	
		Inputs conforming to BS EN60947–5–6:2001 standards for 
	
	
		proximity detectors (NAMUR) 
	
	
		Voltage applied to sensor 
	
	
		7 to 9V dc from 1kΩ ±10% 
	
	
		Input/output characteristics 
	
	
		Normal phase
MTL4510 SWITCH PROXIMITY DETECTOR INTERFACE MTL4510
	MTL4510 SWITCH PROXIMITY DETECTOR INTERFACE MTL4510
		Outputs closed if input > 2.1mA (< 2kΩ in input circuit) 
	
	
		Outputs open if input < 1.2mA (> 10kΩ in input circuit) 
	
	
		Hysteresis: 200µA (650Ω) nominal 
	
	
		Line fault detection (LFD) (when selected) 
	
	
		User-selectable via switches on the side of the unit. 
	
	
		Open-circuit alarm on if Iin < 50µA 
	
	
		Open-circuit alarm off if Iin > 250µA 
	
	
		Short-circuit alarm on if Rin < 100Ω 
	
	
		Short-circuit alarm off if Rin > 360Ω 
	
	
		Note: Resistors must be fitted when using the LFD facility with a contact input 
	
	
		500Ω to 1kΩ in series with switch 
	
	
		20kΩ to 25kΩ in parallel with switch 
	
	
		Safe-area outputs
MTL4510 SWITCH PROXIMITY DETECTOR INTERFACE MTL4510
	MTL4510 SWITCH PROXIMITY DETECTOR INTERFACE MTL4510
		Floating solid-state outputs compatible with logic circuits 
	
	
		Operating frequency: dc to 500Hz 
	
	
		Max. off-state voltage: ± 35V 
	
	
		Max. off-state leakage current: ± 50µA 
	
	
		Max. on-state resistance: 25Ω 
	
	
		Max. on-state current: ± 50mA 
	
	
		LED indicators 
	
	
		Green: power indication 
	
	
		Yellow: four: on when output active 
	
	
		Red: LFD indication + faulty channel’s yellow LED flashes 
	
	
		Maximum current consumption 
	
	
		40mA at 24V (with all output channels energised) 
	
	
		Power dissipation within unit 
	
	
		0.96W at 24V, with 10mA loads 
	
	
		Safety description (each channel) 
	
	
		Uo=10.5V Io=14mA Po=37mW Um = 253V rms or dc
MTL4510 SWITCH PROXIMITY DETECTOR INTERFACE MTL4510
Contact Information
Email address:Jackie@hkxytech.com jackie2018@126.com
Whatsapp:+86 15717178751
Skype:Jackie@hkxytech.com
Telegram:+86 15717178751
Phone:+86 15717178751
	MTL4510 SWITCH PROXIMITY DETECTOR INTERFACE MTL4510
Contact Information
Email address:Jackie@hkxytech.com jackie2018@126.com
Whatsapp:+86 15717178751
Skype:Jackie@hkxytech.com
Telegram:+86 15717178751
Phone:+86 15717178751
          RELATED PRODUCTS
      
         
     
     
                             
                             
                             
                             
                             
                             
                             
                             
                            