Foxboro SRD991-BDBD7EAANR-V01 Positioner
- Product Name:Foxboro SRD991-BDBD7EAANR-V01 Positioner
- Product Number:SRD991-BDBD7EAANR-V01
- Brand:Foxboro
- Views:94
-
Foxboro SRD991-BDBD7EAANR-V01 Positioner
的详细介绍Foxboro SRD991-BDBD7EAANR-V01 Intelligent Positioner
SRD991-BDBD7EAANR-V01 Intelligent Positioner with HART, PROFIBUS PA or FOUNDATION Fieldbus H1 for EEx ia Intrinsically Safe Applications
The intelligent positioner SRD991 is designed to control pneumatic valve actuators and is available in the version EEx ia (Intrinsic Safety) and can be
operated from any control systems (e.g., the Foxboro I/A Series system).All the diagnostics features can be easily configured and displayed by the
Positioner DTM (Valve Monitor). Moreover, the Positioner DTM enables editing a complete “health” report of the valve with all configuration and diagnostics data. The positioner is available with different communication protocols. This includes versions with analog setpoint (4 to 20 mA) and superimposed HART signal; digital with Profibus communication according to PROFIBUS-PA or FOUNDATION fieldbus H1 according to IEC 1158-2
based on FISCO.The SRD991 also has the capability to control a Partial Stroke Test (PST) that offers operators a tool to identify the trouble-proof function of ESD (Emergency Shut Down) valves.For complete specifications, refer to Product Specification SheetPSS EVE0105 A-(en) or PSS EVE0105 E-(en).
Foxboro SRD991-BDBD7EAANR-V01 Intelligent Positioner
SRD991-BDBD7EAANR-V01 Intelligent Positioner with HART, PROFIBUS PA or FOUNDATION Fieldbus H1 for EEx ia Intrinsically Safe Applications
InputWith HART communication
Two-wire system
Reverse polarity protection . . . built-in standard feature
Signal range . . . . . . . . . . . . . . . . 4 to 20 mA
Operating range . . . . . . . . . . . . 3.6 to 21 mA
Voltage . . . . . . . . . . . . . . . . . . . . DC 12 to 36 V (unloaded
circuit)
Max. load. . . . . . . . . . . . . . . . . . 420 Ohms (8.4 V at 20 mA)
Communication signal . . . . . . HART, 1200 Baud, FSK
modulated on 4 to 20 mA
With Fieldbus communication (acc. to FISCO)
Input signal . . . . . . . . . . . . . . . . digital fieldbus
Supply voltage . . . . . . . . . . . . . DC 9 to 32 V
Operating current . . . . . . . . . . . 10.5 mA ±0.5 mA
(base current)
Current amplitude . . . . . . . . . . ±8 mA
Fault current . . . . . . . . . . . . . . . . base current +0 mA
(+4 mA by means of independent FDE-safety circuit)
PROFIBUS-PA
Data transfer . . . . . . . . . . . . . . . acc. to PROFIBUS- PA
profileclass B based on EN
50170 and DIN 19245 part 4
FOUNDATION Fieldbus H1
Data transfer . . . . . . . . . . . . . . . FF Specification Rev. 1.4,
Link-Master (LAS)
Function blocks . . . . . . . . . . . . PID, AO, 2xDI, DO, IS, OS,
AI, MAI
Without communication 4 to 20 mA
Two-wire system
Reverse polarity protection . . . built-in standard feature
Signal range . . . . . . . . . . . . . . . . 4 to 20 mA
Operating range . . . . . . . . . . . . 3.8 to 21.5 mA
Voltage . . . . . . . . . . . . . . . . . . . . DC 8 to 36 V (unloaded circuit)
Max. load . . . . . . . . . . . . . . . . . . 300 Ohms (6 V at 20 mA)
Common data for all versions
Supply
Supply air pressure . . . . . . . . . . 1.4 to 6 bar (29 to 90 psig)
with spool valve . . . . . . . . . . . . . 1.4 to 7 bar (20 to 105 psig)
Supply air quality . . . . . . . . . . . . according to ISO 8573-1
Max. particle size and density . . . . Class 2
Max. oil contents . . . . . . . . . . . . . . . . Class 3
Foxboro SRD991-BDBD7EAANR-V01 Intelligent Positioner
SRD991-BDBD7EAANR-V01 Intelligent Positioner with HART, PROFIBUS PA or FOUNDATION Fieldbus H1 for EEx ia Intrinsically Safe Applications
Pneumatic connectionNAMUR mounting . . . . . . . . . . 3x female threads 1
⁄4-18 NPT
or G1
⁄4 for pipe diameter
6 to 12 mm (0.24 to 0.47 in)
Direct mounting . . . . . . . . . . . . Instead of output y1 an air
connection on the backside
with O-ring is used (closed
at NAMUR mounting).
Electrical connection
Line entry . . . . . . . . . . . . . . . . . . 1 or 2 cable glands M20 x1.5
or 1
⁄2-14 NPT (with Adapter)
(for additional Adapter
see AD-...)
Cable diameter . . . . . . . . . . . . . 6 to 12 mm (0.24 to 0.47 in)
Screw terminals . . . . . . . . . . . . . 2 terminals for input,
4 terminals for additional
inputs/outputs
Wire cross section
0.3 to 2.5 mm2 (AWG 22-14)
Test Sockets . . . . . . . . . . . . . . . . for connection
of communicator
Technical Data for Stainless Steel Housing
Material Stainless Steel . . . . . . 1.4404/316, 1.25 mm
Protection Class . . . . . . . . . . . . . IP 66 acc. to EN 60529
Impact Resistance . . . . . . . . . . . 7 Joule acc. to EN 50014
Seals . . . . . . . . . . . . . . . . . . . . . . . VMQ (Silicone)
Weight (Complete
Positioner) . . . . . . . . . . . . . . . . . 3.5 kg
Pneumatic Connection . . . . . . 1/4–18 NPT on manifold,
prepared for gauges (option)
Electrical Connection . . . . . . . . M20 x 1.5 (others with Adapter
AD...)
Foxboro SRD991-BDBD7EAANR-V01 Intelligent Positioner
SRD991-BDBD7EAANR-V01 Intelligent Positioner with HART, PROFIBUS PA or FOUNDATION Fieldbus H1 for EEx ia Intrinsically Safe Applications
SRD960 | SRD960 Intelligent Positioner with HART, PROFIBUS PA or FOUNDATION Fieldbus H1 for EEx d Explosion-proof Application |
SRD991 | SRD991 Intelligent Positioner with HART, PROFIBUS PA or FOUNDATION Fieldbus H1 for EEx ia Intrinsically Safe Applications |
DTM | SRD991 and SRD96O DTM (Valve Monitor) for configuration and diagnostics. Valve Health Report generator |
PST | Partial Stroke Testing with SRD991 and SRD960 LCP960 Local Control Panel for PST monitoring |
SRI990 | SRI990 Analog Positioner |
SRI986 | SRI986 Electro-Pneumatic Positioner |
SRI983 | SRI983 Electro-Pneumatic Positioner — explosion proof or EEx d version |
SRP981 | SRP981 Pneumatic Positioner |
SMI983 | SMI983 Electrical Position Transmitter |
SMP981 | SMP981 Pneumatic Position Transmitter |
SGE985 | SGE985 Inductive Limit Switch |
FRS | FRS Filters Regulators |
IP24 | IP24 IP Transducer for Field Service |
SRD991-BDBD7EAANR-V01 Intelligent Positioner
SRD991-BDBD7EAANR-V01 Intelligent Positioner with HART, PROFIBUS PA or FOUNDATION Fieldbus H1 for EEx ia Intrinsically Safe Applications
Jackie Ma
HONGKONG XIEYUAN TECH CO., LIMITED
Add:7-A16,Caishen Commercial Plaza,Hangkou Railway Station,Wuhan, China
M:86-15717178751(WhatsApp & Telegram) | T:+86-27-85887732 | F:86-27-85309780
Email:Jackie@hkxytech.com