SCHNEIDER Soft Stater ATS48C59Q
你添加了1件商品 查看购物车
简单介绍
SCHNEIDER Soft Stater ATS48C59Q
SCHNEIDER Soft Stater ATS48C59Q
SCHNEIDER Soft Stater ATS48C59Q
SCHNEIDER Soft Stater ATS48C59Q
的详细介绍SCHNEIDER Soft Stater ATS48C59Q
| Main | |
| range of product | Altistart 48 |
| product or component type | Soft starter |
| product destination | Asynchronous motors |
| product specific application | Heavy duty industry and pumps |
| device short name | ATS48 |
| power supply voltage | 230...415 V - 15...10 % |
| motor power kW | 132 kW at 230 V connection in the motor supply line for severe applications |
| 160 kW at 230 V connection in the motor supply line for standard applications | |
| 250 kW at 230 V connection to the motor delta terminals for severe applications | |
| 250 kW at 400 V connection in the motor supply line for severe applications | |
| 315 kW at 400 V connection in the motor supply line for standard applications | |
| 355 kW at 400 V connection to the motor delta terminals for severe applications | |
| 400 kW at 400 V connection to the motor delta terminals for standard applications | |
| power dissipation in W | 1386 W for severe applications |
| 1731 W for standard applications | |
| utilisation category | AC-53A |
| type of start | Start with torque control (current limited to 5 In) |
| Icl nominal current | 590 A for connection in the motor supply line for standard applications |
| 590 A for connection in the motor supply line for severe applications | |
| 1022 A for connection to the motor delta terminals for standard applications | |
| 1022 A for connection to the motor delta terminals for severe applications | |
| Complementary | |
| assembly style | With heat sink |
| function available | External bypass (optional) |
| power supply frequency | 50...60 Hz - 5...5 % |
| power supply frequency limits | 47.5...63 Hz |
| device connection | To the motor delta terminals |
| In the motor supply line | |
| discrete output number | 2 |
| discrete output type | (LO1) logic output 0 V common configurable |
| (LO2) logic output 0 V common configurable | |
| (R1) relay outputs fault relay NO | |
| (R2) relay outputs end of starting relay NO | |
| (R3) relay outputs motor powered NO | |
| output absolute accuracy precision | +/- 5 % |
| minimum switching current | 10 mA at 6 V DC for relay outputs |
| maximum switching current | Logic output 0.2 A at 30 V DC |
| Relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 ms | |
| Relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms | |
| discrete input number | 5 |
| discrete input type | PTC, 750 Ohm at 25 °C |
| (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm | |
| discrete input voltage | 24 V <= 30 V |
| discrete input logic | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA |
| starting current | 0.4...1.3 Icl adjustable |
| analogue output type | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm |
| communication port protocol | Modbus |
| connector type | 1 RJ45 |
| communication data link | Serial |
| physical interface | RS485 multidrop |
| transmission rate | 4800, 9600 or 19200 bps |
| max nodes number | 31 |
| protection type | Phase failure: line |
| Thermal protection: motor | |
| Thermal protection: starter | |
| marking | CE |
| operating position | Vertical +/- 10 degree |
| height | 670 mm |
| width | 400 mm |
| depth | 300 mm |
| net weight | 51.4 kg |
| Motor power range AC-3 | 110…220 kW at 200…240 V 3 phases |
| 250…500 kW at 380…440 V 3 phases | |
| 250…500 kW at 200…240 V 3 phases | |
| motor starter type | Soft starter |
| Environment | |
| electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2 |
| Damped oscillating waves level 3 conforming to IEC 61000-4-12 | |
| Electrostatic discharge level 3 conforming to IEC 61000-4-2 | |
| Immunity to electrical transients level 4 conforming to IEC 61000-4-4 | |
| Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 | |
| Voltage/current impulse level 3 conforming to IEC 61000-4-5 | |
| standards | EN/IEC 60947-4-2 |
| product certifications | TCF |
| DNV | |
| UL | |
| CCC | |
| CSA | |
| NOM 117 | |
| SEPRO | |
| GOST | |
| C-Tick | |
| noise level | 55 dB |
| relative humidity | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 |
| ambient air temperature for operation | 40…60 °C (with current derating of 2 % per °C) |
| -10…40 °C (without derating) | |
| ambient air temperature for storage | -25…70 °C |
| operating altitude | <= 1000 m without derating |
| > 1000...2000 m with current derating of 2.2 % per additional 100 m | |
RELATED PRODUCTS