Honeywell Flow Sensor AWM5104VN
Honeywell Flow Sensor AWM5104VN
的详细介绍Honeywell Flow Sensor AWM5104VN
In-Line Flow Measurement
AWM5000 Series Microbridge Mass Airflow Sensors feature a venturi type flow housing. They measure flow as high as 20 standard liters per minute (SLPM) while inducing a maximum pressure drop of 2.25N H2O. The microbridge chip is in direct contact with the flow stream, greatly reducing error possibilities due to orifice or bypass channel clogging.
Rugged, Versatile Package
The rugged plastic package has been designed to withstand common mode pressures up to 50 psi, and the small sensing element allows 100 gs of shock
without compromising performance. The included ‘‘AMP’’ compatible connector provides reliable connection in demanding applications.
On-board Signal Conditioning
Each AWM5000 sensor contains circuitry which performs amplification, linearization, temperature compensation, and gas calibration. Figure 1 (Heater Control Circuit) and Figure 2 (Sensor Bridge Circuit and Amplification Linearization Circuit) illustrate the on-board electrical circuitry for the AWM5000 Series. A 1 to 5 VDC linear output is possible for all listings regardless of flow range (5, 10, 15, or 20 SLPM) or calibration gas (nitrogen, carbon dioxide, nitrous oxide, or argon). All calibration is performed by active laser trimming.
Honeywell Flow Sensor AWM5104VN
FEATURES
·Linear voltage output
·Venturi design
·Remote mounting capability
·Active laser trimming improves interchange ability
·Separate gas calibration types:
– Ar (argon)
– N2 (nitrogen) or
– CO2 (carbon dioxide)
Honeywell Flow Sensor AWM5104VN
AWM5000 ORDER GUIDE
Honeywell Flow Sensor AWM5104VN
Catalog Listing
Flow Range
AWM5101VA
5 SLPM, Argon calibration
AWM5101VC
5 SLPM, CO2 calibration (2)
AWM5101VN
5 SLPM, N2 calibration (1)
AWM5102VA
10 SLPM, Argon calibration
AWM5102VC
10 SLPM, CO2 calibration (2)
AWM5102VN
10 SLPM, N2 calibration (1)
AWM5103VA
15 SLPM, Argon calibration
AWM5103VC
15 SLPM, CO2 calibration (2)
AWM5103VN
15 SLPM, N2 calibration (1)
AWM5104VA
20 SLPM, Argon calibration
AWM5104VC
20 SLPM, CO2 calibration (2)
AWM5104VN
20 SLPM, N2 calibration (1)
Note:
All listings have 1 - 5 VDC linear output with 10 VDC supply over given flow range for aspecific calibration gas.
1. N2 calibration is identical to 02 and air calibration.
2. CO2 calibration is identical to N2O calibration.
3. For additional gas correction factors, see Application Note 3.
OUTPUT CONNECTIONS
Pin 1 + Supply voltage
Pin 2 Ground
Pin 3 No connection
Pin 4 Output voltage
Arrow on bottom of housing indicates direction of flow.