MTL Intrinsic Safety MTL4533 MTL 4500Range Isolator
- Product Name:MTL Intrinsic Safety MTL4533 MTL 4500Range Isolator
- Product Number:MTL4533
- Brand:MTL
- Views:62
-
MTL Intrinsic Safety MTL4533 MTL 4500Range Isolator
的详细介绍MTL Intrinsic Safety MTL4533 MTL 4500Range Isolator
Detailed Product Description
Improving upon the widely adopted, enormously successful, "industry standard" MTL4000 Series was a big challenge but the innovative MTL4500 Series includes several new features for backplane mounting isolating interfaces. This new family easily integrates with the I/O equipment of all major instrumentation and DCS suppliers in the same secure manner as its predecessor.
★Compatible with MTL4000
MTL Intrinsic Safety MTL4533 MTL 4500Range Isolator
ATEX
If the country of installation is governed by the Essential Health and Safety
Requirements (Annex II) of the EU Directive 2014/34/EU [the ATEX Directive - safety of
apparatus] then consult the ATEX safety instructions for safe use in this manual before
installation.
Note: Refer to the website for multiple language safety instructions.
ELECTRICAL PARAMETERS
Refer to the certification documentation for the electrical rating of these products.
FUNCTIONAL SAFETY
If the MTL4500 range of products are to be used in functional safety applications check
that each module has been asssessed for that service and refer to the Safety Manual
for details.
REPAIR
MTL4500 range of products MUST NOT be repaired. Faulty or damaged products must
be replaced with an equivalent certified product.
CLEANING
Should modules require cleaning, use water only on a damp cloth.
Symbols used on the product and in this manual
MTL Intrinsic Safety MTL4533 MTL 4500Range Isolator
ATEX SAFETY INSTRUCTIONS
The following information is in accordance with the Essential Health and Safety Requirements (Annex II) of the EU Directive 2014/34/EU [the ATEX Directive - safety of apparatus] and is provided for those locations where the ATEX Directive is applicable.
General
a) This equipment must only be installed, operated and maintained by competent personnel. Such personnel shall have undergone training, which included instruction on the various types of protection and installation practices, the relevant rules and regulations, and on the general principles of area classification. Appropriate refresher training shall be given on a regular basis. [See clause 4.2 of EN 60079-17].
b) This equipment has been designed to provide protection against all the relevant additional hazards referred to in Annex II of the directive, such as those in clause 1.2.7.
c) This equipment has been designed to meet the requirements of EN 60079-15.
MTL Intrinsic Safety MTL4533 MTL 4500Range Isolator
Installation
a) The installation must comply with the appropriate European, national and local regulations, which may include reference to the IEC code of practice IEC 60079-14. In addition, particular industries or end users may have specific requirements relating to the safety of their installations and these requirements should also be met. For the majority of installations the Directive 1999/92/EC [the ATEX Directive - safety of installations] is also applicable.
b) This apparatus is an associated electrical apparatus and is normally mounted in a non-hazardous [safe] area. Specific apparatus described as Category 3 compliant may be installed in a Zone 2 location providing that the relevant installation conditions are met. When mounted in a Zone 2 location the apparatus must be provided with an enclosure, which offers an additional degree of protection appropriate to the area classification.
c) Unless already protected by design, this equipment must be protected by a suitable enclosure against:
i) mechanical and thermal stresses in excess of those noted in the certification documentation and the product specification
ii) aggressive substances, excessive dust, moisture and other contaminants.Read also the Special Conditions for Safe Use (below) for any additional or more specific information.
Special Conditions of Safe Use for Zone 2 applications
a) When used in Zone 2, the equipment must be installed in an enclosureor an environment that provides a degree of protection of at least IP54
and meets the relevant material and environmental requirements of EN 60079-0:2012 and EN 60079-15:2010.
b) The equipment must not be inserted or removed unless either:
i) the area in which the equipment is installed is known to be nonhazardous or
ii) the circuit to which it is connected has been de-energised.
c) The 24V supply for this equipment must be derived from a regulated power supply complying with the requirements of European Community Directives.
d) For 4511, 4514, 4514B, 4514D, 4516, 4516C, 4517, 4526 & 4532 only:Relay contacts may switch up to 35V, 0.5A and 10W.For 4575: Relay contacts may switch up to 35V, 250mA.
e) Any backplane used does not form part of this certificate and shall be separately certified for use in Zone 2.
f) The associated backplane must be fitted with MTL4500 retention clips (use type MCK45 if not fitted) that allow the equipment to be ‘clipped’
to the backplane. The retention clips shall always be in place when theequipment is energised.
g) For 4573 Maximum Input/Output parameters – see certificate
MTL Intrinsic Safety MTL4533 MTL 4500Range Isolator