Endress+Hauser Proline Promag W 10 Electromagnetic Flowmeter (Order Code: 5WBB2H-AADAEBKA0AUA120AA1)

The Endress+Hauser 5WBB2H-AADAEBKA0AUA120AA1 is a Proline Promag W 10 electromagnetic flowmeter engineered for reliable, maintenance-free flow measurement in basic water and wastewater applications. This model features a lap joint flange design, PTFE liner, and 4-20mA HART communication, making it an ideal choice for raw water intake, distribution networks, and industrial utilities .
Key Features and Product Highlights
-
Proven Electromagnetic Technology: Measures volume flow bidirectionally with accuracy virtually independent of pressure, density, temperature, and viscosity.
-
High Measurement Accuracy: Delivers ±0.5% of measured value ±1 mm/s (0.04 in/s) standard accuracy for dependable process control and monitoring .
-
Lap Joint Flange Connection: Lap joint flange design (option "A" in position 2 of the order code) allows flexible installation and easy alignment in piping systems.
-
PTFE Liner: PTFE liner suitable for process temperatures from -20°C to +90°C (-4°F to +194°F), providing excellent chemical resistance and durability.
-
4-20mA HART Communication: Integrated 4-20mA HART output enables seamless integration with control systems and remote monitoring capabilities .
-
Zero Inlet Run Requirement: Reliable measurement with 0 x DN inlet run without pressure loss, simplifying installation in space-constrained locations .
-
Non-Hazardous Area Approval: Certified for installation in non-hazardous areas, suitable for general industrial and water/wastewater applications.
Order Code Interpretation: 5WBB2H-AADAEBKA0AUA120AA1
Based on Endress+Hauser's Promag W 10 ordering structure:
| Position | Feature | Interpretation |
|---|---|---|
| 1-5 | 5WBB2H | Promag W 10, DN80 (3"), lap joint flange design |
| 6 | A | Approval: Non-hazardous area |
| 7 | A | Process connection: Lap joint flange |
| 8 | D | Transmitter: Enhanced functionality |
| 9 | A | Power supply: 24V DC |
| 10 | E | Output: 4-20mA HART + pulse/frequency/switch output |
| 11 | B | Display: Without local display; configurable via communication |
| 12 | K | Housing: Compact, aluminum coated |
| 13 | A | Sensor connection: Standard |
| 14 | 0 | Electrical connection: Cable gland M20 |
| 15 | A | Liner: PTFE |
| 16 | U | Process connection material: PN10, stainless steel lap joint flange |
| 17 | A | Electrodes: 1.4435/316L stainless steel |
| 18 | 1 | Calibration: 0.5% accuracy |
| 19 | 2 | Device model: 2 |
| 20-21 | 0A | Custom-specific configuration |
| 22-23 | A1 | Additional options |
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | Endress+Hauser |
| Product Series | Proline Promag W 10 |
| Nominal Diameter | DN 80 (3") |
| Measurement Principle | Electromagnetic |
| Max. Measurement Error | Volume flow: ±0.5% o.r. ± 1 mm/s (0.04 in/s) |
| Repeatability | ±0.1% |
| Medium Temperature Range | -20°C to +90°C (-4°F to +194°F) with PTFE liner |
| Ambient Temperature | -40°C to +60°C (-40°F to +140°F) |
| Electrical Conductivity | ≥5 µS/cm for liquids |
| Output Signal | 4-20mA HART, pulse/frequency/switch output |
| Power Supply | 24V DC |
| Housing Material | Compact, aluminum coated |
| Protection Rating | IP66/67, NEMA 4X |
| Wetted Materials | Electrodes: 1.4435 (316L); Liner: PTFE |
| Process Connection | Lap joint flange, PN10, stainless steel |
| Electrical Connection | M20 cable gland |
| Digital Communication | HART protocol |
| Display | Without local display; configurable via HART |
Applications
-
Water & Wastewater Treatment: Raw water intake, distribution networks, effluent monitoring, and treatment process control .
-
Industrial Utilities: Cooling water circuits, process water supply, and utility monitoring.
-
Municipal Infrastructure: Drinking water distribution systems requiring reliable flow measurement.
-
General Industrial Applications: Basic flow measurement tasks where maintenance-free operation is essential.
-
Chemical & Petrochemical: Non-hazardous area installations with compatible process media.
Why Choose the Endress+Hauser 5WBB2H Flowmeter?
-
Reliable Measurement: Zero inlet run requirement and no moving parts ensure consistent accuracy without pressure loss .
-
Application Flexibility: PTFE liner and 316L electrodes provide excellent chemical resistance for diverse water-based applications.
-
Easy Integration: HART communication enables seamless connection to PLCs, DCS, and asset management systems .
-
Low Maintenance: Electromagnetic principle with no moving parts eliminates wear and reduces lifecycle costs.
-
Proven Quality: Backed by Endress+Hauser's global reputation for precision instrumentation and technical support .