Endress+Hauser Proline Promass F 300 Coriolis Flowmeter (Order Code: 8F3B25-AAIBABEFAASAFMWAA1)
- Product Name:Endress+Hauser Proline Promass F 300 Coriolis Flowmeter (Order Code: 8F3B25-AAIBABEFAASAFMWAA1)
- Product Number:8F3B25-AAIBABEFAASAFMWAA1
- Brand:Endress+Hauser
- Views:0
-
Endress+Hauser Proline Promass F 300 Coriolis Flowmeter (Order Code: 8F3B25-AAIBABEFAASAFMWAA1)
的详细介绍
Endress+Hauser Proline Promass F 300 Coriolis Flowmeter
(Order Code: 8F3B25-AAIBABEFAASAFMWAA1)


The Endress+Hauser 8F3B25-AAIBABEFAASAFMWAA1 is a Proline Promass F 300 Coriolis flowmeter, renowned for premium accuracy, robustness, and a compact, easily accessible transmitter. Immune to fluctuating and harsh environments, it is suited for the broadest range of applications requiring precise mass flow, density, and temperature measurement of liquids and gases .
Order Code Interpretation: 8F3B25-AAIBABEFAASAFMWAA1
Based on Endress+Hauser's ordering structure for the Promass F 300 series :
| Position | Code | Interpretation |
|---|---|---|
| 1-5 | 8F3B25 | Promass F 300, DN25 (1 inch) |
| 6-7 | AA | Approval: Non-hazardous area |
| 8-9 | IB | Power supply: 100-230V AC / 24V DC |
| 10 | A | Output 1: 4-20mA HART |
| 11 | B | Output 2: 4-20 mA |
| 12 | E | Output 3: Pulse/frequency/switch output |
| 13 | F | Display/Operation: Standard LCD with touch control |
| 14 | A | Housing: Aluminum, coated |
| 15 | A | Electrical connection: Thread NPT1/2 |
| 16 | S | Measuring tubes: 316L stainless steel |
| 17 | A | Process connection: ASME B16.5 flange |
| 18 | F | Calibration: 0.10% mass flow |
| 19 | M | Device model: Standard |
| 20-22 | WAA1 | Additional options: Basic version |
Key Features & Benefits
-
Premium Accuracy: Achieves ±0.10% mass flow accuracy (standard), with optional ±0.05% (PremiumCal). Density measurement accuracy is ±0.0005 g/cm³ .
-
Wide Temperature Range: Suitable for medium temperatures from -50°C to +350°C (-58°F to +662°F) with high-temperature option, and cryogenic applications down to -196°C .
-
Multivariable Measurement: Simultaneously measures mass flow, volume flow, density, and temperature, reducing the need for multiple process instruments .
-
No Inlet/Outlet Runs Required: Space-saving installation without straight inlet or outlet pipe runs, ideal for tight spaces .
-
Heartbeat Technology: Integrated verification and diagnostics enable measurement reliability and extension of recalibration cycles without process interruption .
-
Flexible Connectivity: Supports HART, PROFIBUS DP/PA, Modbus RS485, PROFINET, EtherNet/IP, and FOUNDATION Fieldbus protocols .
-
Robust Design: IP66/67 protection, resistant to vibration, temperature fluctuations, and harsh environmental conditions .
Technical Specifications

| Parameter | Specification |
|---|---|
| Manufacturer | Endress+Hauser |
| Product Series | Proline Promass F 300 |
| Nominal Diameter | DN 25 (1 inch) |
| Measuring Principle | Coriolis mass flow |
| Mass Flow Accuracy (liquid) | ±0.10% (standard), ±0.05% (optional PremiumCal) |
| Volume Flow Accuracy (liquid) | ±0.10% |
| Mass Flow Accuracy (gas) | ±0.25% |
| Density Accuracy | ±0.0005 g/cm³ |
| Measuring Range | 0 to 18,000 kg/h (0 to 661.5 lb/min) |
| Medium Temperature | -50°C to +350°C (-58°F to +662°F) |
| Max. Process Pressure | PN 100, Class 600 |
| Wetted Materials | Measuring tube: 1.4404 (316/316L); Connection: 1.4404 (316/316L) |
| Outputs | 4-20mA HART, 4-20mA, Pulse/frequency/switch output |
| Power Supply | 100-230V AC / 24V DC (auto-ranging) |
| Housing Material | Aluminum, coated |
| Protection Rating | IP66/67, NEMA Type 4X |
| Display | Backlit graphic display with touch control, WLAN access |
| Communication | HART (standard); Optional: PROFIBUS DP/PA, Modbus, PROFINET, EtherNet/IP |
| Hazardous Area Approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO |
| Functional Safety | IEC 61508, suitable for SIL 2/SIL 3 applications |
| Marine Approvals | LR, DNV, ABS, BV |
| Hygienic Approvals | 3-A, EHEDG (with appropriate process connections) |
Applications
-
Chemical & Petrochemical: Precise mass flow measurement of aggressive and corrosive media .
-
Oil & Gas: Custody transfer measurement, hydrocarbon processing, and LPG applications .
-
Food & Beverage: Hygienic applications with 3-A and EHEDG approvals .
-
Pharmaceutical: High-accuracy dosing and batching with cGMP compliance .
-
Power Generation: Fuel consumption monitoring and energy management .
-
General Industry: Any application requiring high-accuracy flow measurement under varying conditions.
Heartbeat Technology
The Promass F 300 features Heartbeat Technology, which provides :
-
Continuous self-diagnostics for real-time device health monitoring
-
Predictive maintenance recommendations
-
Online verification without process interruption
-
Extended recalibration cycles based on actual device condition
Proline Promass F 300
-
Unmatched Accuracy: Optional PremiumCal delivers ±0.05% mass flow accuracy, ideal for custody transfer and critical applications.
-
Process Resilience: Immune to fluctuating and harsh environments; unaffected by viscosity, density, or flow profile variations .
-
Space-Saving Design: No inlet or outlet run requirements allow installation in the tightest spaces.
-
Integrated Diagnostics: Heartbeat Technology reduces maintenance costs and extends calibration intervals.
-
Flexible I/O Configuration: Up to 3 configurable I/Os support various fieldbus protocols and connectivity needs.
-
Global Approvals: ATEX, IECEx, NACE, marine, and hygienic certifications ensure worldwide deployment .
Q&A
Q1: What is the mass flow accuracy of the 8F3B25-AAIBABEFAASAFMWAA1?
A: This model achieves ±0.10% mass flow accuracy for liquids as standard. An optional PremiumCal version with ±0.05% accuracy is also available for applications requiring the highest precision .
Q2: What is the maximum process temperature for this flowmeter?
A: The standard medium temperature range is -50°C to +150°C. With the high-temperature option, it can operate up to +350°C, and a cryogenic option supports temperatures down to -196°C .
Q3: Does this flowmeter require straight inlet and outlet pipe runs?
A: No. The Promass F 300 requires no straight inlet or outlet runs, saving valuable installation space compared to other flow measurement technologies