Current Location: Home> Product Class> Endress+Hauser>

Endress+Hauser Proline Promass F 300 Coriolis Flowmeter (Order Code: 8F3B25-AAIBABEFAASAFMWAA1)

  • Product Name:Endress+Hauser Proline Promass F 300 Coriolis Flowmeter (Order Code: 8F3B25-AAIBABEFAASAFMWAA1)
  • Product Number:8F3B25-AAIBABEFAASAFMWAA1
  • Brand:Endress+Hauser
  • Views:0
你添加了1件商品 查看购物车
简单介绍
The Endress+Hauser 8F3B25-AAIBABEFAASAFMWAA1 is a Proline Promass F 300 Coriolis flowmeter, renowned for premium accuracy, robustness, and a compact, easily accessible transmitter. Immune to fluctuating and harsh environments, it is suited for the broadest range of applications requiring precise mass flow, density, and temperature measurement of liquids and gases

Endress+Hauser Proline Promass F 300 Coriolis Flowmeter (Order Code: 8F3B25-AAIBABEFAASAFMWAA1)

的详细介绍

Endress+Hauser Proline Promass F 300 Coriolis Flowmeter
(Order Code: 8F3B25-AAIBABEFAASAFMWAA1)


The Endress+Hauser 8F3B25-AAIBABEFAASAFMWAA1 is a Proline Promass F 300 Coriolis flowmeter, renowned for premium accuracy, robustness, and a compact, easily accessible transmitter. Immune to fluctuating and harsh environments, it is suited for the broadest range of applications requiring precise mass flow, density, and temperature measurement of liquids and gases .

Order Code Interpretation: 8F3B25-AAIBABEFAASAFMWAA1

Based on Endress+Hauser's ordering structure for the Promass F 300 series :

Position Code Interpretation
1-5 8F3B25 Promass F 300, DN25 (1 inch)
6-7 AA Approval: Non-hazardous area
8-9 IB Power supply: 100-230V AC / 24V DC
10 A Output 1: 4-20mA HART
11 B Output 2: 4-20 mA
12 E Output 3: Pulse/frequency/switch output
13 F Display/Operation: Standard LCD with touch control
14 A Housing: Aluminum, coated
15 A Electrical connection: Thread NPT1/2
16 S Measuring tubes: 316L stainless steel
17 A Process connection: ASME B16.5 flange
18 F Calibration: 0.10% mass flow
19 M Device model: Standard
20-22 WAA1 Additional options: Basic version

Key Features & Benefits

  • Premium Accuracy: Achieves ±0.10% mass flow accuracy (standard), with optional ±0.05% (PremiumCal). Density measurement accuracy is ±0.0005 g/cm³ .

  • Wide Temperature Range: Suitable for medium temperatures from -50°C to +350°C (-58°F to +662°F) with high-temperature option, and cryogenic applications down to -196°C .

  • Multivariable Measurement: Simultaneously measures mass flow, volume flow, density, and temperature, reducing the need for multiple process instruments .

  • No Inlet/Outlet Runs Required: Space-saving installation without straight inlet or outlet pipe runs, ideal for tight spaces .

  • Heartbeat Technology: Integrated verification and diagnostics enable measurement reliability and extension of recalibration cycles without process interruption .

  • Flexible Connectivity: Supports HART, PROFIBUS DP/PA, Modbus RS485, PROFINET, EtherNet/IP, and FOUNDATION Fieldbus protocols .

  • Robust Design: IP66/67 protection, resistant to vibration, temperature fluctuations, and harsh environmental conditions .

Technical Specifications

Parameter Specification
Manufacturer Endress+Hauser
Product Series Proline Promass F 300
Nominal Diameter DN 25 (1 inch)
Measuring Principle Coriolis mass flow
Mass Flow Accuracy (liquid) ±0.10% (standard), ±0.05% (optional PremiumCal) 
Volume Flow Accuracy (liquid) ±0.10%
Mass Flow Accuracy (gas) ±0.25% 
Density Accuracy ±0.0005 g/cm³ 
Measuring Range 0 to 18,000 kg/h (0 to 661.5 lb/min) 
Medium Temperature -50°C to +350°C (-58°F to +662°F)
Max. Process Pressure PN 100, Class 600 
Wetted Materials Measuring tube: 1.4404 (316/316L); Connection: 1.4404 (316/316L) 
Outputs 4-20mA HART, 4-20mA, Pulse/frequency/switch output
Power Supply 100-230V AC / 24V DC (auto-ranging)
Housing Material Aluminum, coated 
Protection Rating IP66/67, NEMA Type 4X 
Display Backlit graphic display with touch control, WLAN access
Communication HART (standard); Optional: PROFIBUS DP/PA, Modbus, PROFINET, EtherNet/IP 
Hazardous Area Approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO
Functional Safety IEC 61508, suitable for SIL 2/SIL 3 applications 
Marine Approvals LR, DNV, ABS, BV
Hygienic Approvals 3-A, EHEDG (with appropriate process connections)

Applications

  • Chemical & Petrochemical: Precise mass flow measurement of aggressive and corrosive media .

  • Oil & Gas: Custody transfer measurement, hydrocarbon processing, and LPG applications .

  • Food & Beverage: Hygienic applications with 3-A and EHEDG approvals .

  • Pharmaceutical: High-accuracy dosing and batching with cGMP compliance .

  • Power Generation: Fuel consumption monitoring and energy management .

  • General Industry: Any application requiring high-accuracy flow measurement under varying conditions.

Heartbeat Technology

The Promass F 300 features Heartbeat Technology, which provides :

  • Continuous self-diagnostics for real-time device health monitoring

  • Predictive maintenance recommendations

  • Online verification without process interruption

  • Extended recalibration cycles based on actual device condition

Proline Promass F 300

  • Unmatched Accuracy: Optional PremiumCal delivers ±0.05% mass flow accuracy, ideal for custody transfer and critical applications.

  • Process Resilience: Immune to fluctuating and harsh environments; unaffected by viscosity, density, or flow profile variations .

  • Space-Saving Design: No inlet or outlet run requirements allow installation in the tightest spaces.

  • Integrated Diagnostics: Heartbeat Technology reduces maintenance costs and extends calibration intervals.

  • Flexible I/O Configuration: Up to 3 configurable I/Os support various fieldbus protocols and connectivity needs.

  • Global Approvals: ATEX, IECEx, NACE, marine, and hygienic certifications ensure worldwide deployment .


Q&A

Q1: What is the mass flow accuracy of the 8F3B25-AAIBABEFAASAFMWAA1?


A: This model achieves ±0.10% mass flow accuracy for liquids as standard. An optional PremiumCal version with ±0.05% accuracy is also available for applications requiring the highest precision .


Q2: What is the maximum process temperature for this flowmeter?


A: The standard medium temperature range is -50°C to +150°C. With the high-temperature option, it can operate up to +350°C, and a cryogenic option supports temperatures down to -196°C .


Q3: Does this flowmeter require straight inlet and outlet pipe runs?


A: No. The Promass F 300 requires no straight inlet or outlet runs, saving valuable installation space compared to other flow measurement technologies 

 