Current Location: Home> Product Class> Endress+Hauser> Flowmeter>

Endress+Hauser Proline Prowirl F 200 Vortex Flowmeter (7F2C40-C3BCCADAAAAAA+SKA1+DEJAJBLAPBZ1)

  • Product Name:Endress+Hauser Proline Prowirl F 200 Vortex Flowmeter (7F2C40-C3BCCADAAAAAA+SKA1+DEJAJBLAPBZ1)
  • Product Number:7F2C40-C3BCCADAAAAAA+SKA1+DEJAJBLAPBZ1
  • Brand:Endress+Hauser
  • Views:4
你添加了1件商品 查看购物车
简单介绍
Code Component General Interpretation 7F2C40 Proline Prowirl F 200, DN40 (1½") sensor -C3BCCADAAAAAA Extended code specifying approvals, wetted materials, process connections, outputs, and housing configuration +SKA1 Additional hardware/software options (e.g., specific approvals, cable type, or software packages) +DEJAJBLAPBZ1 Final configuration options including calibration details and custo

Endress+Hauser Proline Prowirl F 200 Vortex Flowmeter (7F2C40-C3BCCADAAAAAA+SKA1+DEJAJBLAPBZ1)

的详细介绍

Endress+Hauser Proline Prowirl F 200 Vortex Flowmeter
 (7F2C40-C3BCCADAAAAAA+SKA1+DEJAJBLAPBZ1)

The Endress+Hauser Proline Prowirl F 200 is a premier multivariable vortex flowmeter designed for precise measurement of wet/saturated/superheated steam, gases, and liquids (including cryogenic applications). This model, with order code root 7F2C40, indicates a DN40 (1½ inch) nominal diameter sensor, making it ideal for medium-scale industrial flow applications requiring the highest accuracy.

As a true multivariable device, it integrates temperature and pressure measurement directly, enabling real-time mass flow, energy flow, and heat flow difference calculations without requiring separate instruments. With Heartbeat Technology for continuous self-diagnostics and verification, and optional PremiumCal accuracy for custody transfer applications, the Prowirl F 200 sets the industry standard for energy management and process safety in challenging environments.

Order Code Interpretation

The order code 7F2C40-C3BCCADAAAAAA+SKA1+DEJAJBLAPBZ1 is composed of several specific feature selections. 

Code Component General Interpretation
7F2C40 Proline Prowirl F 200, DN40 (1½") sensor
-C3BCCADAAAAAA Extended code specifying approvals, wetted materials, process connections, outputs, and housing configuration
+SKA1 Additional hardware/software options (e.g., specific approvals, cable type, or software packages)
+DEJAJBLAPBZ1 Final configuration options including calibration details and customization codes
 

7F2C40-C3BCCADAAAAAA+SKA1+DEJAJBLAPBZ1

Approval:
C3
CSA C/US XP Cl.I,II,III Div.1 Gr.A-G
-
-
Output; Input:
B
4-20mA HART, pulse/freq./switch output
-
-
Display; Operation:
C
SD02 4-line; push buttons + data backup function
-
-
Housing:
C
GT20 dual compartment,alu,coated,compact
-
-
Cable, Remote Version:
A
Not used
-
-
Electrical Connection:
D
Thread NPT1/2
-
-
Sensor Version; DSC-Sensor; Meas. Tube:
AA
Volume; 316L; 316L -40...+260oC/-40...+500oF
-
-
DSC-Sensor Seal:
A
Graphite, -200oC… +400oC, -328oF…752oF
-
-
Pressure component:
A
Not used
-
-
Process Connection:
AAS
Cl.150 RF Sch.40, flange ASME B16.5
-
-
Flow Calibration:
K
0.75% volume 3-point
-
-
Device Model:
A1
1
-
-
>>Customized Parameterization:
DE
Output 1, gas
-
-
>>Test, Certificate:
JA
Inspection certificate 3.1, EN10204 (material certificate wetted parts)
-
-
JB
Pressure test, internal procedure, test report (measuring tube + DSC-sensor)
-
-
>>Additional Approval:
LA
SIL
-
-
>>Accessory Enclosed:
PB
Weather protection cover
-
-
>>Marking:
Z1
Tagging (TAG), see additional spec.
-
50105107

Endress+Hauser Proline Prowirl F 200 Vortex Flowmeter
 (7F2C40-C3BCCADAAAAAA+SKA1+DEJAJBLAPBZ1)


Installation Requirements

To attain the specified level of accuracy, minimum inlet and outlet runs must be maintained:

Flow Obstruction Min. Inlet Run Min. Outlet Run
Reduction by one size 15 × DN 5 × DN
Single elbow (90°) 20 × DN 5 × DN
Double elbow (opposite) 25 × DN 5 × DN
Double elbow 3D (not in one plane) 40 × DN 5 × DN
T-piece 20 × DN 5 × DN
Expansion 17 × DN + 8 × h 5 × DN
Control valve 50 × DN 5 × DN


FAQs

Q1: What is the nominal diameter of the 7F2C40?

A: The 7F2C40 order code root indicates a DN40 (1½ inch) sensor. This size is suitable for medium-scale flow applications where a compact footprint is desired while maintaining excellent accuracy. The DN40 configuration can handle flow rates up to 2,100 m³/h (1,520 ft³/min) for liquids and 28,000 m³/h (16,600 ft³/min) for steam/gas, depending on the medium.

Q2: Can the Prowirl F 200 measure wet steam accurately?

A: Yes. The Prowirl F 200 is specifically designed with inline wet steam detection and measurement capability for DN 25 to 300 (1 to 12") sizes. It can detect and quantify wet steam conditions, which is critical for accurate energy management in steam systems. The device must be installed according to orientation guidelines (orientation C: horizontal, transmitter head down) for wet steam applications.


Endress+Hauser Proline Prowirl F 200 Vortex Flowmeter
 (7F2C40-C3BCCADAAAAAA+SKA1+DEJAJBLAPBZ1)



 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com