- Siemens
- ABB
-
A-B
- MTL
- Pepperl Fuchs
- Phoenix
- Weidmuller
-
IFM
-
Hirschman
-
Hach
-
Schneider
- Norgren
- Fluke
- Sick
- Moxa
- Honeywell
- Yokogawa
- Rosemount
- Emerson
- Beamex
- Festo
- Oring
- Danfoss
- Rotork YTC
- Atlas Copco
-
Allen Bradley
-
YASKAWA
- Triconex
-
Endress+Hauser
-
Dungs
- Belimo
-
Jaquet
-
WIKA
-
UE
- Foxboro
- SMC
-
bifold
-
Nagano Keiki
-
AIRTAC
-
Dynisco
-
proface
-
Woodward
-
CPC
-
Durag
-
Crowcon
-
Bently Nevada
- Krohne
- York
- Bray
-
B&R
- MSA
- AZBIL
- Omron
-
PEPPER+FUCHS
-
MEANWELL
- GE
- XECRO
-
KONAN
-
Fairford
-
testo
-
Emotron
- PR electronics
容器组件
ABB Head-mount temperature transmitter TTH300 origin in Germany large quantity arrived
日期:2025-05-02 01:48
浏览次数:393
摘要:ABB Head-mount temperature transmitter TTH300 origin in ABB Germany;
The TTH300 HART, PROFIBUS PA or FOUNDATION Fieldbus temperature transmitter inproven two-wire technology features a multitude of new functions and enhanced diagnostic information.
ABB Head-mount temperature transmitter TTH300 origin in Germany large quantity arrived
TTH300 - A NEW GENERATION OF HART TEMPERATURE TRANSMITTERS
The new generation of HART Temperature Transmitters.
The TTH300 HART features a multitude of new functions and enhanced diagnostic information. The temperature transmitter can be configured using the DSV401 (SMART VISION) device management tool or via FDT/DTM technology.
Universal sensor input (RTD, thermo couple, Ohm, mV)
Various sensor error-calibration possibilities (one point, two point, Callendar- van Dusen)
Sensor Backup / autom. Sensor redundancy switching (2x Pt100 3-wire connection)
Freestyle characteristics (32 supporting points)
Output signal (temperature linear), 4...20 mA, HART signal
Accuracy 0.1 %, long-term stability 0.05 % per year
Unique new user friendly connection technology from the outside
Input:
Resistance thermometersThermocouples
Resistance-remote signalling unit (0 ... 5000)
Voltages, mV transmitter (-125 ... 1100 mV)
Input functionality
1 or 2 sensors (e.g. 2 x Pt100 3-L)
Sensor backup/redundancy
Sensor drift monitoring
Output
2-wire technique
4 ... 20 mA temperature linear
HART signal
Measurement error
0,1 K
Specific linearization
Callendar van Dusen coefficients
Customer specific curve / 32 tie points
Continuous sensor and self-monitoring
Supply voltage monitoring
Wire break and corrosion monitoring (NE - Extended diagnostics (NE 107)
Device safety in accordance with NE 53.
Approvals for explosion protection
intrinsically safe: ATEX EEx ia (Zone 0), FM,
non-incendive: ATEX EEx n A
Configuration
Display with TTH300 configuration function
FDT/DTM
SMART VISION DSV401
EDD