The MTLx575 converts a low-level dc signal from a temperature sensor mounted in a hazardous area into a 4/20mA current for driving a safearea
load. Software selectable features include linearisation, ranging, monitoring, testing and tagging for all thermocouple types and 2-, 3-or 4-wire RTDs. (For thermocouple applications the HAZ-CJC plug on terminals 1–3 includes an integral CJC sensor). Configuration is carried out using a personal computer. A single alarm output is provided and may be configured for process alarm or to provide notice of early thermocouple failure.MTL5575 TEMPERATURE CONVERTER large quantity arrived

MTL5575 SPECIFICATION
See also common specification
Number of channels: One
Signal source
THC types J, K, T, E, R, S, B or N to BS 60584 and XK
mV input
RTDs 2/3/4-wire platinum to BS 60751
Pt 100, Pt 500, Pt 1000
Cu-50 & Cu-53
Ni 100/500/1000 DIN 43760
Location of signal source
Zone 0, IIC, T4-6 hazardous area
Division 1, Group A, hazardous location
Input signal range
–75 to +75mV, or 0 to 400Ω (0 to 1000Ω Pt & Ni sensors)
Input signal span
3 to 150mV, or 10 to 400Ω (10 to 1000Ω Pt & Ni sensors)
RTD excitation current
200µA nominal
Cold junction compensation
Automatic or selectable
MTL5575 TEMPERATURE CONVERTER large quantity arrived


Early burnout
Early burnout detection for thermocouples (when selected)
Alarm trips when loop resistance increase is > 50Ω
Output range: 4 to 20mA nominal into 600Ω max.
Alarm output (configurable)
Relay ON in alarm, 250mA @ 35V max
Maximum lead resistance (THC)
600Ω
Response time
Configurable - 500 ms default
(Accuracy at 100/200ms - contact MTL)
LED indicator
Green: power and status indication
Yellow: alarm indication, on when contacts are closed
Maximum current consumption (with 20mA signal)
50mA at 24V
Power dissipation within unit (with 20mA signal)
1.2W at 24V
Safety description
Refer to certificate for parameters. Um=253V rms or dc
Configurator
A personal computer running MTL PCS45 software with a PCL45USB serial interface.