Yokogawa Zirconia Oxygen Analyzer ZR402G converter large qty arrived



Yokogawa Zirconia Oxygen Analyzer ZR402G converter large qty arrived

System

The Zirconia Oxygen Analyzer System includes the ZR402G converter and ZR22 detector and is capable of measuring oxygen concentration or humidity in non-combustion applications with a single analyzer. Its LCD touch screen provides easy operation, and digital communications are standard, allowing for remote configuration and troubleshooting. Yokogawa Zirconia Oxygen Analyzer ZR402G converter large qty arrived

ZR402G Converter

The ZR402G converter is equipped with an LCD touch screen featuring an intuitive operating system with a variety of display modes and error codes with built-in error details. Other standard functions include measurement, calculation, and self-test maintenance functions to enable easier operation and troubleshooting.

ZR22G/ZR22S Detector

The ZR22G separate-type detector is an in-situ probe that uses a high-reliability zirconia sensor. The zirconia cell and heater assembly can be replaced in the field, reducing maintenance costs. The ZR22S separate-type detector for explosion-proof applications is also available and offers the following explosion-proof certifications:

  • ATEX
  • FM
  • CSA

Features

Accurate Maintenance Scheduling with Advanced Diagnostics

Predictive diagnostics from the analyzer simplify troubleshooting and provide technicians with the necessary data to create a minimal calibration schedule.

Reduced Downtime with a Robust Cell Design

The probe's cell is designed with a large measurement surface area, making it less susceptible to contaminants, which allows for longer periods between cell replacements and calibrations.  

 

Increased Measurement Availability with an Intuitive Design

The probe uses a long-life, high-reliability zirconia sensor and has an intuitive design that enables easy troubleshooting and repair in the field, minimizing downtime and reducing costs since technicians only need to replace the needed parts.

Increased Process Uptime with Customized Training Resources

Yokogawa’s knowledgeable representatives and support technicians provide operation and repair training for all Yokogawa products both in the factory and in the field. Training ranges from basic operation to advanced troubleshooting, helping you achieve more efficient operations and simplified maintenance.

Yokogawa Zirconia Oxygen Analyzer ZR402G converter large qty arrived
Measurement object Oxygen concentration in combustion exhaust gas and mixed gas
Measurement system Zirconium oxide sensor
Measurement range 0.01 to 100 vol% O2
Output signal 4 to 20 mA DC, two points (ZR402G) (maximum load resistance 550Ω)
Setting range Any setting in the range of 0 - 5 vol%O2 to 0 - 100 vol%O2 (in 1 vol% O2), or partial range
Digital communication (HART) 250 to 550Ω, depending on number of field devices connected to the loop (multi-drop mode)
Sample gas pressure -5 to +250 kPa (Pressure compensation option necessary over +5 kPa)
Sample gas temperature 0 to 700℃ (Probe only)
700 to 1871℃ (with 0.15m probe with JIS 5K 32 FF flange and ZR22P High Temperature Probe Adapter)
Probe length 0.15, 0.4, 0.7, 1.0, 1.5, 2.0, 2.5, 3.0, 3.6, 4.2, 4.8, 5.4 m
Contact output Four points (one is fail-safe, normally open)
Contact input Two points
Calibration Method; zero/span calibration
Calibration mode; automatic, semi-automatic and manual (with an LCD touchscreen)
Construction of detector (ZR22G) Heater and thermocouple replaceable construction. 
Non-explosion-proof. Equivalent to NEMA4X/IP66
Construction of converter (ZR402G) Non-explosion-proof, outdoor installation, equivalent to NEMA4X/IP66
Ambient Temperature Probe (ZR22G): -20 to 150℃
Converter (ZR402G): -20 to 55℃)
Reference Gas System

Instrument Air (preferred): 50 kPa (200 kPa with check valve) + the pressure inside the furnace; Approx. 1 Nl/min consumption

Natural convection

Power supply 85 to 264 V AC; 45 to 66 Hz