MTL 5523 Safety Barries Isolaters 



·MTL5523 SOLENOID/ALARM DRIVER with line fault detection, IIC


·With the MTLx523 interface, an on/off device in a hazardous area can be controlled by a volt-free contact or logic signal in the safe area. It is suitable for driving loads such as solenoids. Line fault detection (LFD), which operates irrespective of the output state, is signalled by a safearea solid-state switch which de-energises MTLx523, or energises MTL4523R, if a field line is open or short–circuited. Earth fault detection can be provided by connecting an MTL4220 earth leakage detector to terminal 3.
·Number of channels One Location of load Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A, hazardous location Minimum output voltage
·Number of channels : One
Location of load : Zone 0, IIC, T4–6 hazardous area if suitably certified, Div. 1, Group A, hazardous location

·MTL 5523 Safety Barries Isolaters 

·Hazardous-area output

Minimum output voltage: 13.6V at 48mA
Maximum output voltage: 24V from 180O
Maximum off-state output voltage: 4V from 180O
Current limit: 48mA

MTL 5523 Safety Barries Isolaters 

·Output ripple: < 0.5% of maximum output, peak to peak
·Control input
Suitable for switch contacts, an open collector transistor or logic drive.
(Internal contact wetting voltage 12V @ 0.2mA contact closed.Not suitable for voltage control via series diode.)
Output turns on if input switch closed, transistor on or< 1.4V applied across control input
Output turns off if input switch open, transistor off or> 4.5V applied across control input
·Response time : Output within 10% of final value within 100ms
·Line fault detection (LFD)
Open or short circuit in field cabling de-energises* solid state line-fault signal.
LFD transistor is switched on*, provided that the field circuit impedance is > 55O and < 4kO.
·Line fault signal characteristics
Maximum off-state voltage: 35V
Maximum off-state leakage current: 10µA
Maximum on-state voltage drop: 2V
Maximum on-state current: 50mA


MTL 5523 Safety Barries Isolaters 

·LED indicators

Green: power indication
Yellow: output status, on when output active
Red: LFD indication, on when line fault detected
·Maximum current consumption : 100mA at 24V dc

·Power dissipation within unit : 1.2W with typical solenoid valve, output on, 2.0W worst case


MTL 5523 Safety Barries Isolaters 

MTL Barries
MTL5521   Loop powered solenoid driver, IIC  
MTL5522   Loop powered solenoid driver, IIB  
MTL5523   Solenoid driver with LFD  
MTL5523V  Solenoid/Alarm driver with voltage control  
MTL5524   Switch operated solenoid driver  
MTL5525   Loop powered solenoid driver low power  
MTL5526   2ch switch operated relay  


Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd