Emerson EC3-X33 Superheat Controller
Emerson EC3-X33 Superheat Controller
Emerson EC3-X33 Superheat Controller
Description
EC3-X33 is a universal superheat controller used in conjunction with Emerson Electrical Control Valves EX4...EX8.
Emerson EC3-X33 Superheat Controller
Safety Instructions
• Read installation instructions thoroughly. Failure to comply can result in device failure, system damage or personal injury.
• The product is intended for use by persons having the appropriate knowledge and skills.
• Disconnect all voltages from system before installation.
• Do not operate system before all cable connections are completed.
• Comply with local electrical regulations when wiring.
Note: The EC3-X33 series contains a lead, acid gel rechargeable battery. The battery must NOT be disposed of with other commercial waste. Instead, it is the user’s responsibility to pass it
to a designated collection point for the safe recycling of batteries (harmonized directive 98/101/EEC). For further information contact your local environmental recycling center.
Emerson EC3-X33 Superheat Controller
Technical data
Power supply |
24VAC ±10%; 50/60Hz; 1A |
Power consumption |
25VA max. including EX4 … EX8 |
Plug-in connector |
Removable screw terminals wire size 12-20 AWG |
Grounding |
1/4 in spade earth connector |
Protection class |
IP20 |
Connection to ECD-002 |
ECC-Nxx or CAT5 cable with RJ45 connectors |
Digital Inputs |
0/24VAC/DC for stop/start function |
NTC input |
Emerson temperature sensor ECN-N60 |
4-20 mA Analog input |
Emerson PT4-07M / PT4-18M / PT4-30M |
4-20 mA Analog output |
For connection to any 3rd party controller with
12/24VDC power supply and appropriate burden |
Output alarm relay Activated:
Deactivated:
|
SPDT contacts 24V AC/DC, 2 Amp inductive load During normal operation (no alarm condition)
During alarm condition or power supply is OFF |
Stepper motor output for EX4…EX8 |
Maximum current 0.8A with nominal 24VDC operating voltage |