Siemens
-
Siemens Siprotec 7SK...
-
Siemens Siprotec 7UT...
-
Siemens Siprotec 7SL...
-
Siemens Siprotec 7SA...
-
Siemens Siprotec 7SD...
-
Siemens Simatic ET 2...
-
Siemens Siprotec 7SJ...
-
Siemens Power Contac...
-
Siemens Temperature ...
-
Siemens spare parts
-
Siemens motors
-
Siemens Positioner
-
Siemens Drives
-
Siemens PLC
-
Siemens Transmitter
-
Siemens Siprotec 7SK...
- Yokogawa
- Phoenix
- Hirschman
- Honeywell
- ABB
- MTL
- Pepperl Fuchs
-
Schneider
- Emerson
- Weidmuller
- Moxa
-
Endress+Hauser
-
Allen Bradley
-
Mitsubishi
-
IFM
-
SEW
-
Hach
- Norgren
- Fluke
- Danfoss
- Sick
-
A-B
- Rosemount
- Beamex
- Festo
- Oring
- Rotork YTC
- Atlas Copco
-
YASKAWA
- Triconex
-
Dungs
- Belimo
-
Jaquet
-
WIKA
-
UE
- Foxboro
- SMC
-
bifold
-
Nagano Keiki
-
AIRTAC
-
Dynisco
-
proface
-
Woodward
-
CPC
-
Durag
- Krohne
- York
- Bray
-
B&R
- MSA
- AZBIL
- Omron
-
PEPPER+FUCHS
-
MEANWELL
-
Crowcon
- GE
- XECRO
-
KONAN
-
Fairford
-
testo
-
Bently Nevada
-
Emotron
- PR electronics
MTL Safety Barrier Isolating Driver MTL4546 / MTL4546C / MTL4546Y / MTL5546 / MTL5546Y
MTL Safety Barrier Isolating Driver MTL4546 / MTL4546C / MTL4546Y / MTL5546 / MTL5546Y
MTL Safety Barrier Isolating Driver MTL4546 / MTL4546C / MTL4546Y / MTL5546 / MTL5546Y
Descriptin
MTL4546/C/Y – MTL5546/Y ISOLATING DRIVER for 4–20mA HART® valve positioners with line fault detection
The MTLx546 accepts a 4/20mA floating signal from a safe-area controller to drive a current/pressure converter (or any other load up to 800Ω) in a hazardous area. For HART valve positioners, the module also permits bi-directional transmission of digital communication signals. Process controllers with a readback facility can detect open or short circuits in the field wiring: if these occur, the current taken into the terminals drops to a preset level. The MTL4546C and the MTLx546Y are very similar to the MTLx546 except that they provide open circuit detection only (i.e. no short-circuit detection).
MTL Safety Barrier Isolating Driver MTL4546 / MTL4546C / MTL4546Y / MTL5546 / MTL5546Y
Specification
Number of channels
One
Location of I/P converter
Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A, hazardous location
Working range
4 to 20mA
Digital signal bandwidth
500Hz to 10kHz
Maximum load resistance
800Ω (16V at 20mA)
Minimum load resistance
90Ω (short-circuit detection at < 50Ω)
Output resistance
> 1MΩ Under/over range capability
Under range
= 1mA Over range = 24mA (load ≤ 520Ω)
Input and output circuit ripple
< 40µA peak-to-peak
Transfer accuracy at 20°C
Better than 20µA
Temperature drift
< 1.0µA/°C
MTL Safety Barrier Isolating Driver MTL4546 / MTL4546C / MTL4546Y / MTL5546 / MTL5546Y

MTL Safety Barrier Isolating Driver MTL4546 / MTL4546C / MTL4546Y / MTL5546 / MTL5546Y
Ordering code
MTL4546 / MTL4546C / MTL4546Y
MTL5546 / MTL5546Y
MTL Safety Barrier Isolating Driver MTL4546 / MTL4546C / MTL4546Y / MTL5546 / MTL5546Y