MTL Megablock Passive MTL Fieldbus Networks F2xx F2xx-XE megablock range
MTL Megablock Passive MTL Fieldbus Networks F2xx F2xx-XE megablock range
MTL Megablock Passive MTL Fieldbus Networks F2xx F2xx-XE megablock range
MTL Megablock Passive MTL Fieldbus Networks F2xx F2xx-XE megablock range
Description
Passive hubs for zone 1 & division 1 fieldbus networks
Megablocks are DIN-rail mounted passive hubs for Foundation™ fieldbus networks. They connect several field devices to the network trunk cable and provide short circuit protection to the segment. Megablocks minimize hand wiring and allow individualdevices to be added to and removed from the segment without disrupting network communication.
A green power LED on each unit indicates whether at least 9V dc is present. Megablocks are available in two, four, eight, ten and twelve drop versions. Multiple Megablocks are easily wired to one another to allow larger segments to be constructed.
Megablocks are available with an integral terminator making them ideal for a star or “chickenfoot” topology where several devices are connected at a single field junction box. Separate Megablock Terminators are also available, whch may be wired easily to any Megablock. Megablocks having a built-in terminator are clearly marked (‘T’) for easy identification by field personnel.
Connections to the Megablock are made using pluggable, screwterminal type connectors. This allows wire terminations to be made to the individual connectors which are then plugged into the Megablock. Devices can then be connected and disconnected easily during commissioning. After commissioning, retaining screws are tightened to secure each connector to the Megablock.
Trunk connections for the fieldbus home-run/ trunk cable are easily identified by their black connectors. Separate numbered connections are provided for each spur drop.
MTL Megablock Passive MTL Fieldbus Networks F2xx F2xx-XE megablock range
Specification
Mounting requirements
35mm DIN rail
Wire capacity
0.14 to 2.5mm2
Recommended screwdriver torque setting: 0.5-0.6Nm
Case material
Lexan polycarbonate
Temperature range
Operating –45º to +70ºC
Storage –50º to +85ºC
Relative humidity 0 to 90%, non-condensing
Voltage required to activate power LED
9.2V dc minimum
Minimum input voltage
10.0V (See Note 1 below)
Maximum input voltage
see certification ratings
Maximum input current
see certification ratings
Trunk-to-trunk voltage drop
0.1V maximum
MTL Megablock Passive MTL Fieldbus Networks F2xx F2xx-XE megablock range
Odering information

MTL Megablock Passive MTL Fieldbus Networks F2xx F2xx-XE megablock range
Code information
F241
F245 F245-XE
F247 F247-XE
F251 F251-XE
F253 F253-XE
F259 F259-XE
F261
F271 F271-XE