Siemens
-
Siemens Siprotec 7SK...
-
Siemens Siprotec 7UT...
-
Siemens Siprotec 7SL...
-
Siemens Siprotec 7SA...
-
Siemens Siprotec 7SD...
-
Siemens Simatic ET 2...
-
Siemens Siprotec 7SJ...
-
Siemens Power Contac...
-
Siemens Temperature ...
-
Siemens spare parts
-
Siemens motors
-
Siemens Positioner
-
Siemens Drives
-
Siemens PLC
-
Siemens Transmitter
-
Siemens Siprotec 7SK...
- Yokogawa
- Phoenix
- Hirschman
- Honeywell
- ABB
- MTL
- Pepperl Fuchs
-
Schneider
- Emerson
- Weidmuller
- Moxa
-
Endress+Hauser
-
Allen Bradley
-
Mitsubishi
-
IFM
-
SEW
-
Hach
- Norgren
- Fluke
- Danfoss
- Sick
-
A-B
- Rosemount
- Beamex
- Festo
- Oring
- Rotork YTC
- Atlas Copco
-
YASKAWA
- Triconex
-
Dungs
- Belimo
-
Jaquet
-
WIKA
-
UE
- Foxboro
- SMC
-
bifold
-
Nagano Keiki
-
AIRTAC
-
Dynisco
-
proface
-
Woodward
-
WAGO
-
CPC
-
PILZ
-
Durag
-
VEICHI
- Krohne
- York
- Bray
-
B&R
- MSA
- AZBIL
- Omron
-
PEPPER+FUCHS
-
MEANWELL
-
Crowcon
- GE
- XECRO
-
KONAN
-
Fairford
-
testo
-
Bently Nevada
-
Emotron
- PR electronics
Pepperl+Fuchs FC-GPCS-RIO16-PF | Termination Board for Honeywell Safety Manager | 16-Channel
Pepperl+Fuchs FC-GPCS-RIO16-PF |

Meta Description:
Pepperl+Fuchs FC-GPCS-RIO16-PF termination board. Designed for Honeywell Safety Manager and Universal I/O cards, this 16-channel board supports multiple signal types with 24V DC supply and blue screw terminals for hazardous areas.
Pepperl+Fuchs FC-GPCS-RIO16-PF Termination Board (Part No.: FC-GPCS-RIO16-PF / 232114)
The Pepperl+Fuchs FC-GPCS-RIO16-PF is a high-density termination board engineered to provide a seamless interface between field devices in hazardous areas and Honeywell control and safety systems . Designed specifically for the Honeywell Safety Manager and Universal I/O platforms, this system board accommodates up to 16 isolated barrier modules and connects directly to 32-channel universal I/O cards such as the RUSIO-3224 . This makes it an essential component for intrinsic safety (IS) applications in process automation.
Key Features and Product Highlights
-
Designed for Honeywell Systems: Specifically configured for seamless integration with Honeywell Safety Manager and Universal Process I/O systems, connecting directly to 32-channel cards like the RUSIO-3224 .
-
Supports Universal I/O Technology: Fully compatible with the HiC2441 Universal Barrier, which automatically adapts to any signal type (AI, AO, DI, DO) without configuration, extending Honeywell's Universal Channel Technology to the field .
-
16-Channel Capacity: Supports up to 16 single-channel isolated barriers, providing a high-density I/O solution for space-constrained cabinets while maintaining signal integrity .
-
Integrated Power Distribution and Redundancy: Features a 24V DC supply with reverse polarity protection. The supply to the modules is decoupled, monitored, and fused, and it supports redundant power connections for increased system availability .
-
Comprehensive Diagnostics: Equipped with a fault indication relay output (volt-free contact) and LED status indicators on the board.
-
Supply LEDs (Green): Two LEDs monitor the status of power supply I and power supply II.
-
Fault LED (Red): Provides a visual alert for power supply faults .
-
-
Hazardous Area Interface: The field side utilizes blue pluggable screw terminals for connecting field devices located in hazardous areas, ensuring secure and reliable terminations with safe electrical isolation up to 375V peak .
-
Wide Module Compatibility: Supports a comprehensive range of Pepperl+Fuchs modules including HiC2025(A) (AI), HiC2031 (AO), HiC2441 (UIO), HiC2831R2 (DI), HiC2853R2 (DI), HiC2871 (DO), HiC5861 (DO), and HiC5863 (DO) .
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | Pepperl+Fuchs |
| Part Number | FC-GPCS-RIO16-PF |
| Alternate Part Number | 232114 |
| Product Type | Termination Board / System Board |
| System Compatibility | Honeywell Safety Manager, Universal I/O (for RUSIO-3224 card) |
| Number of Module Slots | 16 |
| Signal Types Supported | AI, AO, DI, DO, Universal (via HiC2441) |
| Recommended System Cable | CAB-HON-**-S37C32-MX-01000 |
| Supply Connection | TB3: terminals 2, 4 (+); 1, 3 (-) |
| Nominal Voltage | 24 V DC |
| Fusing | 4 A per 16 modules |
| Fault Indication Output | Volt-free relay contact, TB4: terminals 1, 2 (30 V DC, 1 A) |
| Display Elements | LEDs for Supply 1 (green), Supply 2 (green), and Error Status (red) |
| Field Side Connection | Pluggable screw terminals (blue), for hazardous area |
| Control Side Connection | 37-pin Sub-D connector (male) |
| Supply/Fault Connection | Pluggable screw terminals (black) |
| Wire Size (Field) | 0.25 ... 2.5 mm² (24 ... 12 AWG) |
| Ambient Temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Protection Rating | IP20 |
| Mounting | 35 mm DIN mounting rail acc. to EN 60715 |
| Dimensions (W x H x D) | 273 x 155 x 153 mm (10.7 x 6.1 x 6.0 inch) |
| Approvals / Certificates | ATEX, IECEx, UL (for associated IS applications) |
Applications
-
Honeywell DCS and Safety Systems: Ideal for integrating field sensors and actuators from hazardous areas into Honeywell Safety Manager and Experion PKS platforms .
-
Universal Marshalling Solutions: Serves as the foundation for the HiC2441 Universal Barrier, enabling "one device fits all" signal types and simplifying cabinet design for Honeywell's LEAP project methodology .
-
Intrinsic Safety Interfaces: Functions as the backbone for mounting isolated barriers, ensuring safe and organized wiring for intrinsic safety circuits in chemical, petrochemical, and pharmaceutical plants .
-
High-Density Cabinet Design: The 16-channel capacity optimizes I/O density within control panels, reducing overall cabinet footprint and wiring complexity.
-
Greenfield and Brownfield Projects: Equally suited for new DCS installations or for upgrading existing analog marshalling cabinets to modern, high-density digital I/O architectures.