摘要:Endress+Hauser Proline Promag W 10 electromagnetic flowmeter, model 5WBB80-AADAEBKA0AUA121AA1. ±0.5% accuracy, lap joint flange, PTFE liner, for water and wastewater applications.

Endress+Hauser Proline Promag W 10 Electromagnetic Flowmeter
 (Order Code: 5WBB80-AADAEBKA0AUA121AA1)


5WBB80

The Endress+Hauser 5WBB80-AADAEBKA0AUA121AA1 is a Proline Promag W 10 electromagnetic flowmeter designed for basic water and wastewater applications requiring reliable, maintenance-free flow measurement . This model features an easy-to-use operation concept and is suitable for elementary measurement tasks such as raw water intake and distribution networks .

Key Features and Product Highlights

  • Proven Electromagnetic Technology: Provides accurate, bidirectional volume flow measurement virtually independent of pressure, density, temperature, and viscosity .

  • High Measurement Accuracy: Delivers ±0.5% of measured value ±1 mm/s (0.04 in/s) standard accuracy for reliable process control and billing applications .

  • Lap Joint Flange Connection: Features flexible lap joint flange design (option "A" in position 2 of the order code) for easy installation and alignment in piping systems .

  • PTFE Liner: Equipped with PTFE liner suitable for process temperatures from -20°C to +90°C (-4°F to +194°F), providing excellent chemical resistance and durability .

  • 4-20mA HART Communication: Integrated 4-20mA HART output enables seamless integration with control systems and remote monitoring capabilities .

  • Non-Hazardous Area Approval: Certified for installation in non-hazardous areas, suitable for general industrial and water/wastewater applications .

  • Zero Inlet Run Requirement: Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss, simplifying installation in space-constrained locations .

  • International Approvals: Suitable for applications requiring drinking water certifications and compliance with industry standards .

Order Code Breakdown: 5WBB80-AADAEBKA0AUA121AA1

Position Feature Description
1-5 5WBB80 Promag W 10, DN80 (3"), lap joint flange design
6 A Approval: Non-hazardous area
7 A Process connection: Lap joint flange (fixed selection)
8 D Function: Enhanced transmitter 
9 A Power supply: 24V DC
10 E Output: 4-20mA HART + pulse/frequency/switch output
11 B Display: Without display, via communication 
12 K Housing: Compact, aluminum coated
13 A Sensor connection: Not used
14 0 Electrical connection: Cable gland M20
15 A Liner: PTFE
16 U Process connection: PN10, stainless steel lap joint flange 
17 A Electrodes: 1.4435/316L
18 1 Calibration: 0.5% accuracy
19 2 Device model: 2
20-21 1A Custom-specific configuration
22-23 A1 Additional options

Technical Specifications

Parameter Specification
Manufacturer Endress+Hauser
Product Series Proline Promag W 10
Nominal Diameter DN 80 (3")
Measurement Principle Electromagnetic
Measuring Range 0.5 m³/h to 263,000 m³/h (full Promag W range) 
Max. Measurement Error Volume flow: ±0.5% o.r. ± 1 mm/s (0.04 in/s) 
Repeatability ±0.1%
Medium Temperature Range -20°C to +90°C (-4°F to +194°F) with PTFE liner 
Ambient Temperature -40°C to +60°C (-40°F to +140°F) 
Max. Process Pressure PN 40, Class 300, 20K (full Promag W range) 
Electrical Conductivity ≥5 µS/cm for liquids, ≥20 µS/cm for deionized water 
Output Signal 4-20mA HART, pulse/frequency/switch output 
Power Supply 24V DC 
Housing Material Compact, aluminum coated 
Protection Rating IP66/67, NEMA 4X 
Wetted Materials Electrodes: 1.4435 (316L); Liner: PTFE 
Process Connection Lap joint flange, PN10, stainless steel 
Electrical Connection M20 cable gland
Digital Communication HART protocol 
Display Without local display; configurable via HART communication 

Applications

  • Water & Wastewater Treatment: Raw water intake, distribution networks, effluent monitoring, and treatment process control .

  • Industrial Utilities: Cooling water circuits, process water supply, and utility monitoring.

  • Municipal Infrastructure: Drinking water distribution systems requiring international approvals .

  • General Industrial Applications: Basic flow measurement tasks where reliable, maintenance-free operation is essential.

  • Chemical & Petrochemical: Non-hazardous area installations with compatible process media.

Why Choose the Endress+Hauser 5WBB80 Flowmeter?

  • Reliable Measurement: Zero inlet run requirement and no moving parts ensure consistent accuracy without pressure loss .

  • Application Flexibility: PTFE liner and 316L electrodes provide excellent chemical resistance for diverse water-based applications.

  • Easy Integration: HART communication enables seamless connection to PLCs, DCS, and asset management systems.

  • Low Maintenance: Electromagnetic principle with no moving parts eliminates wear and reduces lifecycle costs.

  • Proven Quality: Backed by Endress+Hauser's global reputation for precision instrumentation and technical support.

Heartbeat Technology Compatibility

This model can be optionally configured with Heartbeat Technology for integrated verification and monitoring capabilities. The enhanced transmitter (position 8 "D") supports advanced diagnostic functions, enabling proactive maintenance and compliance validation .



Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd