-
Siemens
-
Siemens Siprotec 7SK...
-
Siemens Siprotec 7UT...
-
Siemens Siprotec 7SL...
-
Siemens Siprotec 7SA...
-
Siemens Siprotec 7SD...
-
Siemens Simatic ET 2...
-
Siemens Siprotec 7SJ...
-
Siemens Power Contac...
-
Siemens Temperature ...
-
Siemens spare parts
-
Siemens motors
-
Siemens Positioner
-
Siemens Drives
-
Siemens PLC
-
Siemens Transmitter
-
Siemens Siprotec 7SK...
- Yokogawa
- Phoenix
- Hirschman
- Honeywell
- ABB
- MTL
- Pepperl Fuchs
-
Schneider
- Emerson
- Weidmuller
- Moxa
-
Endress+Hauser
-
Allen Bradley
-
Mitsubishi
-
IFM
-
SEW
-
Hach
- Norgren
- Fluke
- Danfoss
- Sick
-
A-B
- Rosemount
- Beamex
- Festo
- Oring
- Rotork YTC
- Atlas Copco
-
YASKAWA
- Triconex
-
Dungs
- Belimo
-
Jaquet
-
WIKA
-
UE
- Foxboro
- SMC
-
bifold
-
Nagano Keiki
-
AIRTAC
-
Dynisco
-
proface
-
Woodward
-
WAGO
-
CPC
-
PILZ
-
Durag
-
VEICHI
- Krohne
- York
- Bray
-
B&R
- MSA
- AZBIL
- Omron
-
PEPPER+FUCHS
-
MEANWELL
-
Crowcon
- GE
- XECRO
-
KONAN
-
Fairford
-
testo
-
Bently Nevada
-
Emotron
- PR electronics
In Stock-Endress+Hauser Deltabar PMD55-BA21BA67MGBHAJA1A+AAJBJA | Differential Pressure Transmitter
Endress+Hauser Deltabar PMD55-BA21BA67MGBHAJA1A+AAJBJA
Differential Pressure Transmitter

Endress+Hauser Deltabar PMD55-BA21BA67MGBHAJA1A+AAJBJA | Differential Pressure Transmitter

Endress+Hauser Deltabar PMD55-BA21BA67MGBHAJA1A+AAJBJA | Differential Pressure Transmitter
The Endress+Hauser PMD55-BA21BA67MGBHAJA1A+AAJBJA is a reliable differential pressure transmitter from the Deltabar PMD55 series, featuring a piezoresistive sensor with a welded metallic membrane. It is designed for continuous measurement of pressure differences in liquids, vapors, and gases across process and environmental applications .
This device is ideal for level, volume, or mass measurement in liquids, differential pressure monitoring (e.g., of filters and pumps), and flow measurement in conjunction with primary elements .
Order Code Interpretation: PMD55-BA21BA67MGBHAJA1A+AAJBJA
Based on Endress+Hauser's ordering structure for the Deltabar PMD55 series :
| Position | Code | Interpretation |
|---|---|---|
| Approval | B | ATEX/IECEx hazardous area approval (Ex ia IIC T4) |
| Power Supply; Output | A2 | 4-20 mA HART, 2-wire |
| Housing | 1B | Aluminum housing, IP66/IP67, NEMA 4X |
| Sensor Range | A6 | Measuring cell: 100 mbar...16 bar (1.5...230 psi) |
| Process Connection | 7M | Thread 1/4-18 NPT, 316L stainless steel |
| Calibration Unit | G | Calibration in mbar/bar |
| Additional Options | BHAJA1A+AAJBJA | Custom hardware/software configuration |
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | Endress+Hauser |
| Product Series | Deltabar PMD55 |
| Measuring Principle | Differential pressure, piezoresistive sensor with welded metallic membrane |
| Pressure Measuring Range | 10 mbar to 40 bar (0.15 to 580 psi) |
| Reference Accuracy | Standard: ±0.1%; Platinum: up to ±0.075% (optional) |
| Long-term Stability | 0.05% of URL/year, 0.13% of URL/5 years |
| Turn Down | Up to 100:1 |
| Smallest Calibratable Span | 10 mbar (0.15 psi) |
| Max. Overpressure Limit | 160 bar (2300 psi) on one side |
| Process Temperature | -40°C to +85°C (-40°F to +185°F) |
| Ambient Temperature | -40°C to +85°C (-40°F to +185°F) |
| Output Signal | 4-20 mA HART (2-wire) |
| Supply Voltage (Non-Ex) | 11.5 to 45 V DC |
| Supply Voltage (Ex ia) | 11.5 to 30 V DC |
| Main Wetted Parts | 316L stainless steel |
| Process Membrane Material | 316L, AlloyC |
| Process Connection | 1/4-18 NPT, 316L |
| Material Gasket | Viton, PTFE, EPDM, NBR |
| Fill Fluid | Silicone oil, inert oil |
| Housing Material | Die-cast aluminum, epoxy coated |
| Ingress Protection | IP66/IP67, NEMA 4X |
| Display | Optional 4-line digital display |
| Certifications | ATEX, FM, CSA, IECEx, NEPSI, NACE, SIL2 |
Q&A
Q1: What is the accuracy of the Deltabar PMD55-BA21BA67MGBHAJA1A+AAJBJA?
A: The Deltabar PMD55 offers a standard reference accuracy of ±0.1%. An optional "Platinum" version with up to ±0.075% accuracy is available for applications requiring higher precision . The device also features excellent long-term stability of 0.05% of URL per year .
Q2: Is the PMD55 suitable for use in safety instrumented systems?
A: Yes. The Deltabar PMD55 is SIL2 certified according to IEC 61508 / IEC 61511, making it suitable for use in safety instrumented systems for critical applications such as overfill prevention and emergency shutdown .
Q3: What communication protocols does this version support?
A: The PMD55-BA21BA67MGBHAJA1A+AAJBJA with "A2" output code supports 4-20 mA HART communication . The Deltabar PMD55 series also offers options for PROFIBUS PA and FOUNDATION Fieldbus protocols for flexible system integration .

PMD55-BA21BA67DGBHAJA1A+AA
PMD55-BA21BA67DGBHAJA1A+AAJBJA
PMD55-BA21BA67DGBHAJA1A+AALA
PMD55-BA21BA67DGBHAJA1A+AALAJBJA
PMD55-BA21BA67FGBHAJA1A+AA
PMD55-BA21BA67FGBHAJA1A+AALA
PMD55-BA21BA67GGBHAJA1A+AA
PMD55-BA21BA67GGBHAJA1A+AALA
PMD55-BA21BA67HGBHAJA1A+AA
PMD55-BA21BA67LGBHAJA1A+AA