MTL4517 isolated barrier 2channel DI relay output + LFD alarm safety barrier
- Product Name:MTL4517 isolated barrier 2channel DI relay output + LFD alarm safety barrier
- Product Number:MTL4517
- Brand:MTL
- Views:197
-
MTL4517 isolated barrier 2channel DI relay output + LFD alarm safety barrier
的详细介绍Product overview
MTL4517 isolated barrier 2channel DI relay output + LFD alarm safety barrier
MTL4517 2channel DI relay output + LFD alarm safety barrier
MTL4517 product specification as below for your reference.
MTL4517 isolated barrier 2channel DI relay output + LFD alarm safety barrier
MTL4517 – MTL5517 SWITCH/ PROXIMITY DETECTOR INTERFACE 2-channel, line fault detection, phase reversal The MTLx517 enables two safe-area loads to be controlled, through a relay, by proximity detectors or switches located in a hazardous area. Line faults are signalled through a separate relay and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection.
SPECIFICATION
MTL4517 isolated barrier 2channel DI relay output + LFD alarm safety barrier
See also common specification
Number of channels
Two
Location of switch
Zone 0, IIC, T6 hazardous area
Div.1, Group A, hazardous location
Location of proximity detector
Zone 0, IIC, T4–6 hazardous area, if suitably
certified
Div.1, Group A, hazardous location
Hazardous-area inputs
Inputs conforming to BS EN60947–5–6:2001 standards
for
proximity detectors (NAMUR)
Voltage applied to sensor
7 to 9V dc from 1kΩ ±10%
Input/output characteristics
Normal phase
Outputs closed if input > 2.1mA (< 2kΩ in
input circuit)
Outputs open if input < 1.2mA (> 10kΩ in
input circuit)
Hysteresis: 200µA (650Ω) nominal
Line fault detection (LFD) (when selected)
User selectable by switches on the side of the
module.
Line faults are indicated by the LED for each
channel.
Line fault relay is energised and channel output
relay de-energised
if input line-fault detected
Open-circuit alarm on if Iin < 50µA
Open-circuit alarm off if Iin > 250µA
Short-circuit alarm on if Rin < 100Ω
Short-circuit alarm off if Rin > 360Ω
Note: Resistors must be fitted when using the LFD
facility with a contact input
500Ω to 1kΩ in series with switch
20kΩ to 25kΩ in parallel with switch
Safe-area output
Channel: Two single-pole relays with normally open
contacts
LFD: Single pole relay with changeover contact
(MTL4517)
Single pole relay with normally open contact
(MTL5517)
Note: reactive loads must be adequately suppressed
Maximum current consumption
35mA at 24V
Power dissipation within unit
0.84W at 24V
LED indicators
Green: power indication
Yellow: two: channel status, on when output
energised
Red: two: LFD indication, on when line fault detected
Safety description (each channel)
Uo=10.5V Io=14mA Po=37mW Um = 253V rms or dc
MTL4517 isolated barrier 2channel DI relay output + LFD alarm safety barrier
Other related models for MTL4500 ranges as below
MTL4517 isolated barrier 2channel DI relay output + LFD alarm safety barrier
MTL4501-SR
MTL4504
MTL4510
MTL4510B
MTL4511
MTL4513
MTL4514D
MTL4514_B
MTL4516
MTL4516C
MTL4517
MTL4521
MTL4521L
MTL4523
MTL4523L
MTL4523R
MTL4523V-VL
MTL4524
MTL4524S
MTL4525
MTL4526
MTL4541
MTL4541A
MTL4541AS
MTL4541B
MTL4541P
MTL4541S
MTL4541T
MTL4544
MTL4544A
MTL4544AS
MTL4544B
MTL4544D
MTL4544S
MTL4546
MTL4546C
MTL4546S
MTL4546Y
MTL4549
MTL4549C
MTL4549Y
MTL4573
MTL4575
MTL4576-RTD
MTL4576-THC
MTL4581
MTL4582B
MTL4531
MTL4532
MTL4561
MTL4599
MTL4517 isolated barrier 2channel DI relay output + LFD alarm safety barrier
If you have any other question about MTL4517, please feel free to contact me here!
Contact details
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-027-85508558
Mobile :86-15871691193(Whatapp&Wechat is available)
Skype:xyautomation
E-mail:sales1@hkxytech.com