MTL4511 SWITCH PROXIMITY DETECTOR INTERFACE

  • Product Name:MTL4511 SWITCH PROXIMITY DETECTOR INTERFACE
  • Product Number:MTL4511
  • Brand:MTL
  • Views:210
你添加了1件商品 查看购物车
简单介绍
MTL4511 SWITCH PROXIMITY DETECTOR INTERFACE MTL4511 SWITCH PROXIMITY DETECTOR INTERFACE MTL4511 SWITCH PROXIMITY DETECTOR INTERFACE

MTL4511 SWITCH PROXIMITY DETECTOR INTERFACE

的详细介绍
                      MTL4511 SWITCH PROXIMITY DETECTOR INTERFACE MTL4511
Overview
The MTLx511 enables a safe-area load to be controlled by a switch or proximity detector located in a hazardous-area. When selected, open or short circuit conditions in the field wiring are detected by the linefault-detect (LFD) facility and also indicated on the top of the module.Phase reversal for the channel is selected by a switch on the side of the module and output is provided by changeover relay contacts.
MTL4511 SWITCH PROXIMITY DETECTOR INTERFACE MTL4511
SPECIFICATION
See also common specification
Number of channels
One
Location of switches
MTL4511 SWITCH PROXIMITY DETECTOR INTERFACE MTL4511
Zone 0, IIC, T6 hazardous area
Div. 1, Group A hazardous location
Location of proximity detector
Zone 0, IIC, T4–6 hazardous area if suitably certified
Div. 1, Group A hazardous location
Hazardous-area inputs
Inputs conforming to BS EN60947–5–6:2001 standards for
proximity detectors (NAMUR)
Voltage applied to sensor
7 to 9V dc from 1kΩ ±10%
Input/output characteristics
Normal phase
MTL4511 SWITCH PROXIMITY DETECTOR INTERFACE MTL4511
Outputs closed if input > 2.1mA (< 2kΩ in input circuit)
Outputs open if input < 1.2mA (> 10kΩ in input circuit)
Hysteresis: 200µA (650Ω) nominal
Line fault detection (LFD) (when selected)
User-selectable via switches on the side of the unit. A line fault is
indicated by an LED. The channel output relay is de-energised if an
input line fault is detected.
Open-circuit alarm on if Iin < 50µA
Open-circuit alarm off if Iin > 250µA
Short-circuit alarm on if Rin < 100Ω
Short-circuit alarm off if Rin > 360Ω
Note: Resistors must be fitted when using the LFD facility with a contact input
500Ω to 1kΩ in series with switch
20kΩ to 25kΩ in parallel with switch
Safe-area output
Single pole relay with changeover contacts
Note: reactive loads must be adequately suppressed
MTL4511 SWITCH PROXIMITY DETECTOR INTERFACE MTL4511
Related model
MTL4546C
MTL4546Y

MTL5042 
MTL5018AC
MTL5501-SR
MTL5510
MTL5510B
MTL5511
MTL5513 
MTL5514
MTL5514D
MTL5516C
MTL5517
MTL5521
MTL5522
MTL5523
MTL5524
MTL5525
MTL5526
MTL5541
MTL5541A
MTL5541AS 
MTL5541S
MTL5544
MTL5544A
MTL5544AS
MTL5544D
MTL5544S
MTL5546
MTL5546Y
MTL5549
MTL5549Y
MTL5573
MTL5575
MTL5576-RTD
MTL5576-THC
MTL5581
MTL5582
MTL5582B
MTL5991 
MTL5531
MTL5532
MTL5533
MTL5561
MPA5500
MTL5051
MTL5053
MTL5314
MTL5599 
MTL7056AC
MTL7787+

Contact Information
Email address:Jackie@hkxytech.com  jackie2018@126.com
Whatsapp:+86 15717178751     
Skype:Jackie@hkxytech.com
Telegram:+86 15717178751
Phone:+86 15717178751

 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd