Yokogawa RAMC Metal Short-stroke Rotameter RAMC05-D4SS-71M5-T90NNN

  • Product Name:Yokogawa RAMC Metal Short-stroke Rotameter RAMC05-D4SS-71M5-T90NNN
  • Product Number:RAMC05-D4SS-71M5-T90NNN
  • Brand:Yokogawa
  • Views:298
你添加了1件商品 查看购物车
简单介绍
Yokogawa RAMC Metal Short-stroke Rotameter RAMC05-D4SS-71M5-T90NNN Yokogawa RAMC Metal Short-stroke Rotameter RAMC05-D4SS-71M5-T90NNN Yokogawa RAMC Metal Short-stroke Rotameter RAMC05-D4SS-71M5-T90NNN

Yokogawa RAMC Metal Short-stroke Rotameter RAMC05-D4SS-71M5-T90NNN

的详细介绍

Yokogawa RAMC Metal Short-stroke Rotameter RAMC05-D4SS-71M5-T90NNN

Yokogawa RAMC Metal Short-stroke Rotameter RAMC05-D4SS-71M5-T90NNN

Description

RAMC Variable Area Flow Meter

316L Stainless Steel Construction

2% Full Scale accuracy
4-20ma output                               Hart Protocol Available
Adjustable Limit Switches
0.95 to 550 GPM
0.42 to 1050 SCFM

Yokogawa RAMC Metal Short-stroke Rotameter RAMC05-D4SS-71M5-T90NNN

 FEATURES


- Different process connections like flanges according EN and ASME

- All wetted parts in stainless steel or PTFE

- Maximum flow 0.025 - 130 m³/h water resp. 0.75 - 1400 m³/h air (20 °C / 1.013 bar abs)

- Measuring accuracy acc. Directive VDI/VDE 3513 sheet 2 (qG=50%)

- Float damping to avoid float bouncing with gas applications

- Optional heat tracing (with steam or fluid heat carrier)

- Indicator in stainless steel, aluminium, protection class IP66/67

- Local indicator without additional power supply

- Microprocessor controlled transmitter with 24 V, 115 V or 230 V power supply

- Intrinsically safe version (Ex-i): ATEX, IECEx, FM, CSA, NEPSI, PESO, KOSHA, EAC, INMETRO

- Flame proof version (Ex-d): ATEX, IECEx, NEPSI, PESO, KOSHA, EAC, TS

- Dust explosion proof: ATEX, IECEx, NEPSI, PESO, KOSHA

- Ex for non- electrical RAMC: ATEX, EAC

- Suitable for SIL application, FMEDA report available

- Limit switches, also available as “Fail Safe” version

Models and Suffix Codes

Yokogawa RAMC Metal Short-stroke Rotameter RAMC05-D4SS-71M5-T90NNN

Model

Suffix code

Description

Restrictions

RAMC01

 

Size DN 15 (½ inch)

for D4, D6, A1, A2, A3, T4, R4, T6, G6

RAMC23

Size DN 20 (¾ inch)

for D4, D6, A1, A2, A3, T4, R4, T6, G6

RAMC02

Size DN 25 (1 inch)

for D4, D6, A1, A2, A3, S2, S4, S5, T4,R4, T6, G6

RAMC03

Size DN 32 (1¼ inch)

for D4, D6, A1, A2, A3, S4, T6, G6

RAMC04

Size DN 40 (1½ inch)

for D4, D6, A1, A2, A3, S4, S5, T6, G6

RAMC05

Size DN 50 (2 inch)

for D4, D5, D6, A1, A2, A3, S2, S4,T4, R4

RAMC06

Size DN 65 (2½ inch)

for D4, D5, A1, A2, A3, S2, S4, T4, R4,T6, G6

RAMC08

Size DN 80 (3 inch)

for D4, D5, A1, A2, A3, S2, S4

RAMC09

3½ inch

for A1, A2

RAMC10

Size DN 100 (4 inch)

for D2, D4, A1, A2, S4, S4

RAMC12

Size DN 125 (5 inch)

for D2, A1, A2, S2

RAMC15

Size DN 150 (6 inch)

for D2, A1, A2

RAMCNN

Without measuring tube

 

Process connection

-D2

EN fange PN 16, process connection dimension + facing acc. EN 1092-2 Form B1

 

-D4

EN fange PN 40, process connection dimension + facing acc. EN 1092-2 Form B1

 

-D5

EN fange PN 63, process connection dimension + facing acc. EN 1092-2 Form B1

 

-D6

EN fange PN 100, process connection dimension + facing acc. EN 1092-2 Form B1

 

-A1

ASME fange class 150, process connection dimension + facing acc. ASME B 16.5

 

-A2

ASME fange class 300, process connection dimension + facing acc. ASME B 16.5

 

-A3

ASME fange class 600, process connection dimension + facing acc. ASME B 16.5

 

-T6

NPT PN 40 female thread

 

-G6

G PN 40 female thread

 

-R4

Rp removable female thread

 

-S2

Thread acc. DIN 11851

 

-S4

Tri- clamp PN 10, PN16 acc. DIN 32676

 

-T4

NPT removable female thread

 

-S5

Flange Rosita PN 10

 

-NN

Without process connection

 

Material of wetted parts

SS

Stainless steel

 

PF

Tefon lining

 

NN

Without wetted parts

Only with RAMCNN

Cone / Float

-nnnn

See tables 10 ... 12

 

-NNNN

Without measuring tube / without foat

Only with RAMCNN

Indicator/   Transmitter

-T

Indicator local

 

-E

Indicator electronic

 

-G

Indicator electronic with Profbus PA

Only with output 429

-H

Indicator electronic with HART

Only with output 424

-N

Without indicator

Only with housing NN

Housing / Type

90

Housing round blanc; SS

 

91

Housing round yellow; Al

 

NN

Without housing

Only with indicator N

Power supply / Output

240

230 V AC ; 4- wire; 0-20 mA

Only with indicator E; not with limit switches

244

230 V AC ; 4- wire; 4-20 mA

Only with indicator E; not with limit switches

140

115 V AC ; 4- wire; 0-20 mA

Only with indicator E; not with limit switches

144

115 V AC ; 4- wire; 4-20 mA

Only with indicator E; not with limit switches

430

24 V DC; 3- wire; 0-20 mA

Only with indicator E

434

24 V DC; 3- wire; 4-20 mA

Only with indicator E

424

24 V DC; 2- wire; 4-20 mA

Only with indicator E, H

429

Profbus PA; 9 ... 32 V DC

Only with indicator G; not with limit switches

NNN

Without power supply

Only with indicator T or N


Yokogawa RAMC Metal Short-stroke Rotameter RAMC01

Yokogawa RAMC Metal Short-stroke Rotameter RAMC23

Yokogawa RAMC Metal Short-stroke Rotameter RAMC02

Yokogawa RAMC Metal Short-stroke Rotameter RAMC03

Yokogawa RAMC Metal Short-stroke Rotameter RAMC04

Yokogawa RAMC Metal Short-stroke Rotameter RAMC05

RAMC06

RAMC08

RAMC09

RAMC10

RAMC12

RAMC15

 

RAMC01-A2SS-44S0-E90424/SD/KS1/BG/P6/P2

RAMC05-A1SS-71L5-T90NNN

RAMC05-D4SS-72S5-E90424

RAMC05-D4SS-72L5-E90424

RAMC05-D4SS-72L5-T90NNN

RAMC05-A2SS-63S2-T90NNN/B1/P6

RAMC02-A1SS-64V2-T90NNN/A13/B1/BG/P6/PP/lE1

RAMC02-A1SS-64V2-T90NNN/A13/B1/BG/P6/PP/lE1

RAMC02-A1SS-64M2-T90NNN/A13/B1/BG/K7/KS1/P6/PP/SD/

RAMC02-A1SS-51S0-T90NNN/A13/B1/BG/P6/PP/SD/IE1

RAMC02-A1SS-51S0-T90NNN/A13/B1/BG/P6/PP/SD/IE1

RAMC02-A1SS-63L2-T90NNN/A13/B1/BG/K7/KS1/P6/PP/SD/

RAMC02-A1SS-54L1-T90NNN/A13/B1/BG/P6/PP/IE1

RAMC02-A1SS-63L2-T90NNN/A13/B1/BG/K6/KS1/P6/PP/W4E

RAMC02-A1SS-53M1-H90424/A13/B1/BG/KS1/P6/PP/SD/IE1

RAMC02-A1SS-64L2-H90424/A13/B1/BG/KS1/P6/PP/IE1

RAMC02-A1SS-57L1-T90NNN/A13/B1/BG/K7/KS1/P6/PP/SD/

RAMC02-A1SS-61M1-T90NNN/A13/B1/BG/K6/KS1/P6/PP/W4E

RAMC02-T6SS-62L1-T91434 RAMC02-T6SS-62L1-T91434

RAMC02-S4SS-62V2-T90424/NS1/BG/IE1

RAMC02-S2SS-54L1-E90424/SD/ID2/IE2

RAMC02-S2SS-54L1-E90424/SD/ID2

RAMC02-D4SS-64V2-T90NNN/BG

RAMC02-D4SS-64V2-H91424/NF1

RAMC02-D4SS-64S2-E66424/IE1

RAMC02-D4SS-63V2-H91424/NF1

RAMC02-D4SS-63M2-E90424/NS1

RAMC02-D4SS-62L1-E90424/SD/IE1

RAMC02-D4SS-53L1-H90424/SD

RAMC02-D4SS-47S0-E90424/SD/IE1

RAMC02-D4SS-43S0-T90NNN/A13/BG/K6/KS1/P6/SD

RAMC01-A1SS-53L1-T90NNN/BG/P6

RAMC01-A1SS-53S1-T90NNN/B0/K1/P6/IE1

RAMC01-A1SS-53S1-T90NNN/BG/P6

RAMC01-A1SS-53S1-T90NNN/BG/P6/IE1

RAMC01-A2SS-53L1-T90NNN/B1/P6

RAMC01-A2SS-54V1-T90NNN/K6/KS1/P6/PP/IE1

RAMC01-A2SS-62V1-T90NNN/K6/KS1/P6/PP/IE1

RAMC01-D4SS-43S0-H91424/KF1

RAMC01-T4SS-57M1-T90NNN/K9/KS1

RAMC01-D4SS-43S0-H90424/BG/KS1/P3/SD/IE1

Yokogawa RAMC Metal Short-stroke Rotameter RAMC05-D4SS-71M5-T90NNN

 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780