Pepperl+Fuchs isolated barrier KFD2-EB2.R4A.B

  • Product Name:Pepperl+Fuchs isolated barrier KFD2-EB2.R4A.B
  • Product Number:
  • Brand:Pepperl Fuchs
  • Views:216
你添加了1件商品 查看购物车
简单介绍
Pepperl+Fuchs isolated barrier KFD2-EB2.R4A.B Pepperl+Fuchs isolated barrier KFD2-EB2.R4A.B Pepperl+Fuchs isolated barrier KFD2-EB2.R4A.B

Pepperl+Fuchs isolated barrier KFD2-EB2.R4A.B

的详细介绍
Pepperl+Fuchs isolated barrier KFD2-EB2.R4A.B


Redundant Power Feed Module KFD2-EB2.R4A.B

Pepperl+Fuchs isolated barrier KFD2-EB2.R4A.B

Features
• Interface for Power Rail
• Used for redundant configuration
• Supply current ≤ 4 A
• Replaceable fuse
• Relay contact output, reversible
• LED status indication


Function
The power feed module KFD2-EB2.R4A.B interfaces 24 V DC power to the Power Rail at a maximum current of 4 A and is designed for applications requiring redundant power. The twin input terminals allow for daisy-chaining of supply (max. 10 A).
A green LED on the front of the unit indicates that power is on, and a red LED illuminates during error conditions.Pepperl+Fuchs isolated barrier KFD2-EB2.R4A.B.
In the event of a field wiring or barrier fault from any barrier on the Power Rail, the integral collective error messaging relay alerts the controller via a single digital I/O point. This relay can be configured as normally open or normally closed. Pepperl+Fuchs isolated barrier KFD2-EB2.R4A.B
Additionally, the bus implemented in the Power Rail is forwarded to the outside terminals 13 and 15 for usage with KFD2-WAC2-Ex1.D RS 485 connection. Terminal 14 is only for test purposes.
In the sense of functional safety (SIL) the device provides no dangerous failures. Thereby the safe condition of the supplied barrier must be defined as the powerless state. Thus the device will not influence the safety calculation or the SIL value.
This device is compatible with all versions of the Power Rail and provides group fusing.
Note: Redundant systems require two KFD2-EB.R4A.B modules.

Detailed Models

Pepperl+Fuchs isolated barrier KFD2-EB2.R4A.B

P+F KCD2-SCD-1
P+F KCD2-SCD-EX1
P+F KCD2-SR-EX1.LB
P+F KCD2-SR-EX2
P+F KCD2-STC-1
P+F KCD2-STC-EX1
P+F KCD2-STC-EX1.2O
P+F KCD2-UT2-EX1
P+F KFA6-SR2-Ex1.W
P+F KFD0-SD2-Ex1.1045
P+F KFD2-CD2-EX1
P+F KFD2-CRG2-EX1.D
P+F KFD2-DWB-1.D
P+F KFD2-EB2
P+F KFD2-GU-1
P+F KFD2-GUT-Ex1.D
P+F KFD2-SCD2-EX2.LK
P+F KFD2-SH-EX1.T.OP
P+F KFD2-SOT2-Ex2
P+F KFD2-SR2-Ex1.W.LB
P+F KFD2-SR2-Ex2.W
P+F KFD2-ST2-Ex2
P+F KFD2-STC4-1
P+F KFD2-STC4-EX2 
P+F KFD2-STC4-Ex2
P+F KFD2-UT2-1
P+F KFD2-UT2-2
P+F KFD2-UT2-EX1
P+F KFD2-UT2-Ex2
P+F KFD2-VR4-EX1.26
KFD2-SR2-Ex2.W
KFD2-SL2-Ex1
KFD2-SR2-Ex1.W
KFD2-STC4-Ex1
KFD2-SR2-EX.1.W.LB
KFD2-EB2.R4A.B
KFD2-SCD2-EX1.LK
KFD2-SR2-EX2.W
KFD2-SL2-EX2.B
KFD0-TT-EX1
KFD0-TR-EX1
KFD2-STC4-EX2
KFD2-UFC-EX1.D
KFD2-SCD2-EX2-LK
KFD2-CD-EX1.32-15
KFD2-STC4-EX1.2O
KFD2-SH-EX1.T.OP
KFD2-SR2-EX2.2S
KFD2-BR-1.PA.93
KFD2-UT2-EX2
KFD2-UFC-EX1.D
KFD0-SD2-EX1.1045
KFD2-SOT2-EX1.LB
KFD2-STC4-EX1.20
KFD2-STC4-1.20,
KFD2-SCD2-EX2.LK
KFD2-SCD2-2.LK
KFD2-SH-EX1
KFD0-SD2-Ex2.1245
KFD2-SL2-Ex1.LK
KFD2-BR-Ex1.3PA.93
KFD2-CD2-EX2
KFD2-UT2-EX2
KFD2-STC4-EX1.2O
KFD2-CR4-1.2O
KFD2-CD2-EX1
KFD2-SL2-EX2
KLD2-PR-1.IEC
KFD2-WAC2-EX1.D
KFD2-UFT-EX2.D
KFD2-UFC-1.D
KFD-STC4-EX1.2O.DE
KFD2-SCD2-EX1
KFD2-PT2-Ex1
KFD2-SR2-EX2.2S
KFD0-SD2-EX1.1045
KCD2-E2L 
KCD2-STC-EX1
KFD2-SR2-EX1.W
KFD2-SCD2-EX1-LK
KCD2-SCD-EX1
KFD2-UT2-EX1
KFD2-VR4-EX1.26
KFD2-SR2-EX1.W.LB
KFDO-RSH-1
KFD2-GS-1.2W 
KFD2-EB.R4A.B
KFD0-SCS-EX1.55
KFD2-EX1.32
KFD2-STC4-Ex1-Y1.
KFD2-SR2-EX2.2S
KFD2-SCD2-EX2.LK

 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd