Pepperl+Fuchs isolated barrier KFD2-SCD2-1.LK

  • Product Name:Pepperl+Fuchs isolated barrier KFD2-SCD2-1.LK
  • Product Number:KFD2-SCD2-1.LK
  • Brand:Pepperl Fuchs
  • Views:162
你添加了1件商品 查看购物车
简单介绍
Pepperl+Fuchs isolated barrier KFD2-SCD2-1.LK Pepperl+Fuchs isolated barrier KFD2-SCD2-1.LK Pepperl+Fuchs isolated barrier KFD2-SCD2-1.LK

Pepperl+Fuchs isolated barrier KFD2-SCD2-1.LK

的详细介绍
Pepperl+Fuchs isolated barrier KFD2-SCD2-1.LK



SMART Current Driver KFD2-SCD2-1.LK

Pepperl+Fuchs isolated barrier KFD2-SCD2-1.LK

Features
• 1-channel signal conditioner
• 24 V DC supply (Power Rail)
• Current output up to 700 Ω load
• HART I/P and valve positioner
• Line fault detection (LFD)
• Accuracy 0.05 %
• Terminal blocks with test sockets
• Up to SIL 2 acc. to IEC 61508


Function
This signal conditioner KFD2-SCD2-1.LK drives SMART I/P converters, electrical valves, and positioners and provides isolation for non-intrinsically safe applications. Digital signals are superimposed on the analog values at the field or control side and are transferred bi-directionally.
Current transferred across the DC/DC converter is repeated at terminals 1 and 2. An open and shorted field circuit presents a high input impedance to the control side to allow line fault detection by control system. Pepperl+Fuchs isolated barrier KFD2-SCD2-1.LK
If the loop resistance for digital communication is too low, an internal resistor of 250 Ω between terminals 8 and 9 is available, which may be used as the HART communication resistor. Sockets for the connection of a HART communicator are integrated into the terminals of the device. Pepperl+Fuchs isolated barrier KFD2-SCD2-1.LK
A unique collective error messaging feature is available when used with the Power Rail system.


Detailed Models
KFD2-SR2-Ex2.W
KFD2-SL2-Ex1
KFD2-SR2-Ex1.W
KFD2-STC4-Ex1
KFD2-SR2-EX.1.W.LB
KFD2-EB2.R4A.B
KFD2-SCD2-EX1.LK
KFD2-SR2-EX2.W
KFD2-SL2-EX2.B
KFD0-TT-EX1
KFD0-TR-EX1
KFD2-STC4-EX2
KFD2-UFC-EX1.D
KFD2-SCD2-EX2-LK
KFD2-CD-EX1.32-15
KFD2-STC4-EX1.2O
KFD2-SH-EX1.T.OP
KFD2-SR2-EX2.2S
KFD2-BR-1.PA.93
KFD2-UT2-EX2
KFD2-UFC-EX1.D
KFD0-SD2-EX1.1045
KFD2-SOT2-EX1.LB
KFD2-STC4-EX1.20
KFD2-STC4-1.20
KFD2-SCD2-EX2.LK
KFD2-SCD2-2.LK
KFD2-SH-EX1
KFD0-SD2-Ex2.1245
KFD2-SL2-Ex1.LK
KFD2-BR-Ex1.3PA.93
KFD2-CD2-EX2
KFD2-UT2-EX2
KFD2-STC4-EX1.2O
KFD2-CR4-1.2O
KFD2-CD2-EX1
KFD2-SL2-EX2
KLD2-PR-1.IEC
KFD2-WAC2-EX1.D
KFD2-UFT-EX2.D
KFD2-UFC-1.D
KFD-STC4-EX1.2O.DE
KFD2-SCD2-EX1
KFD2-PT2-Ex1
KFD2-SR2-EX2.2S
KFD0-SD2-EX1.1045
KCD2-E2L 
KCD2-STC-EX1
KFD2-SR2-EX1.W
KFD2-SCD2-EX1-LK
KCD2-SCD-EX1
KFD2-UT2-EX1
KFD2-VR4-EX1.26
KFD2-SR2-EX1.W.LB
KFDO-RSH-1
KFD2-GS-1.2W 
KFD2-EB.R4A.B
KFD0-SCS-EX1.55
KFD2-EX1.32
KFD2-STC4-Ex1-Y1.
KFD2-SR2-EX2.2S
KFD2-SCD2-EX2.LK
KFA5-SR2-EX1.W.LB
KFD2-RR-EX1
KFD2-SCD-EX1.LK
KFA6-STR-1.24.500
Z787.H
KFD0-CS-EX2.50P
KFD0-CS-EX2.51P
KFA6-SR2-EX1.W.LB
KFA5-SR2-EX1.W
KFD2-ST2-EX2
KFD2-DWB-1.D
KFD2-UT-EX1
KFD2-SR2-2.2S
HD2-FBPS-1.500
HD2-DM-B
KFD2-GU-Ex1.D
KFD2-PT2-EX1-5
KFD2-DWB-Ex1.D
KFA6-DWB-EX1.D
KFD2-STV4-EX2-2
Z728
Z828
KFD0-CS-Ex1.54P
KFU8-DW-1.D
KFD0-RO-Ex2
S1SD-1TI-1U
KFD2-GUT-1.D
KFD0-SCS-1.55
KFD2-DWB-Ex1.D
KFD2-PT2-EX1-5
KFA6-DWB-EX1.D
KFD2-STV4-EX2-2
Z728
Z828
KFD0-CS-Ex1.54P
KFD0-RO-Ex2
KFD2-GUT-1.D
KFD2-SCD2-1.LK
KFD2-GU-Ex1
Pepperl+Fuchs isolated barrier KFD2-SCD2-1.LK

 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd