SPXCDUSNo1M Honeywell Analytics Sensepoint XCD

  • Product Name:SPXCDUSNo1M Honeywell Analytics Sensepoint XCD
  • Product Number:SPXCDUSNo1M
  • Brand:Honeywell
  • Views:104
你添加了1件商品 查看购物车
简单介绍
SPXCDUSNo1M Honeywell Analytics Sensepoint XCD SPXCDUSNo1M Honeywell Analytics Sensepoint XCD SPXCDUSNo1M Honeywell Analytics Sensepoint XCD

SPXCDUSNo1M Honeywell Analytics Sensepoint XCD

的详细介绍
SPXCDUSNo1M Honeywell Analytics Sensepoint XCD

The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. Users can modify detector operation using the LCD and magnetic switches without ever needing to open the unit. This enables one-man, nonintrusive operation and reduces routine maintenance time and costs.SPXCDUSNo1M Honeywell Analytics Sensepoint XCD

Key Features
SPXCDUSNo1M Honeywell Analytics Sensepoint XCD
Flammable (catalytic or infrared), toxic and oxygen versions available
New and retrofit applications
Suitable for indoor or outdoor use


Instrument - UL/CSA Approval (316SS) with ModBus

SPXCDUSNo1M Honeywell Analytics Sensepoint XCD

SPXCDUSNFXM UL/CSA approved SP XCD Flammable CAT 0-100LEL (20 to 100LEL, 10%LEL) with 316SS, 3/4"NPT Entry, with ModBus
SPXCDUSNRXM UL/CSA approved SP XCD CH4(Methane) IR 0-100LEL (20 to 100LEL, 10%LEL) with 316SS, 3/4"NPT Entry, with ModBus
SPXCDUSNPXM UL/CSA approved SP XCD Propane IR 0-100LEL (20 to 100LEL, 10%LEL) with 316SS, 3/4"NPT Entry, with ModBus
SPXCDUSNo1M UL/CSA approved SP XCD Oxygen 25.0%/Vol with 316SS, 3/4"NPT Entry, with ModBus
SPXCDUSNHXM UL/CSA approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with 316SS, 3/4"NPT Entry, with ModBus
SPXCDUSNCXM UL/CSA approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with 316SS, 3/4"NPT Entry, with ModBus
SPXCDUSNNXM UL/CSA approved SP XCD Nitrogen Dioxide 0-10ppm (10.0 to 50.0ppm, 5ppm) with 316SS, 3/4"NPT Entry, with ModBus
SPXCDUSNG1M UL/CSA approved SP XCD Hydrogen 0-1000ppm with 316SS, 3/4"NPT Entry, with ModBus

SPXCDUSNB1M UL/CSA approved SP XCD Carbon Dioxide IR 0-2.00%VOL with 316SS, 3/4"NPT Entry, with ModBus

SPXCDUSNo1M Honeywell Analytics Sensepoint XCD

 