Current Location: Home> Product Class> Endress+Hauser>

Endress+Hauser Proline Promag W 10 Electromagnetic Flowmeter (5WBB1H-AADAEBKA0AUA120AA1)

  • Product Name:Endress+Hauser Proline Promag W 10 Electromagnetic Flowmeter (5WBB1H-AADAEBKA0AUA120AA1)
  • Product Number:5WBB1H-AADAEBKA0AUA120AA1
  • Brand:Endress+Hauser
  • Views:1
你添加了1件商品 查看购物车
简单介绍
Endress+Hauser Proline Promag W 10 electromagnetic flowmeter, model 5WBB1H-AADAEBKA0AUA120AA1. ±0.5% accuracy, HART, PTFE liner, DN25-3000, IP68, for water/wastewater.

Endress+Hauser Proline Promag W 10 Electromagnetic Flowmeter (5WBB1H-AADAEBKA0AUA120AA1)

的详细介绍

Endress+Hauser Proline Promag W 10 Electromagnetic Flowmeter
(Order Code: 5WBB1H-AADAEBKA0AUA120AA1)


Endress+Hauser 5WBB1H-AADAEBKA0AUA120AA1 | Proline Promag W 10 Electromagnetic Flowmeter

The Endress+Hauser 5WBB1H-AADAEBKA0AUA120AA1 is a Proline Promag W 10 electromagnetic flowmeter designed for basic water and wastewater applications requiring reliable, maintenance-free flow measurement . This Fundamental series device simplifies every step from engineering to servicing while delivering Endress+Hauser's proven quality and Heartbeat Technology for integrated verification .

Key Features and Product Highlights

  • ±0.5% Measurement Accuracy: Standard volume flow accuracy of ±0.5% o.r. ± 1 mm/s (0.04 in/s) for reliable process control 

  • Zero Inlet Run Requirement: Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss, simplifying installation in space-constrained locations 

  • Wide Size Range: Available from DN 25 to 3000 (1 to 120 inches), accommodating diverse pipe sizes 

  • Heartbeat Technology: Integrated verification enables on-demand diagnostics and compliance validation without process interruption 

  • International Drinking Water Approvals: Certified for potable water applications with ACS, KTW-BWGL, NSF 61, and WRAS BS 6920 approvals 

  • IP68 Protection: Degree of protection IP68 (Type 6P enclosure) with EN ISO 12944 corrosion protection for underground or underwater installation 

Order Code Interpretation: 5WBB1H-AADAEBKA0AUA120AA1

Based on Endress+Hauser's Proline Promag W 10 ordering structure , this specific configuration includes:

Position(s) Code Interpretation
1-5 5WBB1H Promag W 10, DN25-3000, PTFE liner option
6 A Approval: Non-hazardous area
7 A Process connection: Lap joint flange
8 D Transmitter: Enhanced functionality
9 A Power supply: 24V DC
10 E Output: 4-20mA HART + pulse/frequency/switch
11 B Display: Without local display; configurable via communication
12 K Housing: Compact, aluminum coated
13 A Sensor connection: Standard
14 0 Electrical connection: Cable gland M20
15 A Liner: PTFE
16 U Process connection material: PN10, stainless steel lap joint flange
17 A Electrodes: 1.4435 (316L) stainless steel
18 1 Calibration: 0.5% accuracy
19 2 Device model: 2
20-21 0A Custom-specific configuration
22-23 A1 Additional options


Technical Specifications

Parameter Specification
Manufacturer Endress+Hauser
Product Series Proline Promag W 10
Measuring Principle Electromagnetic
Nominal Diameter DN 25 to 3000 (1 to 120") 
Measuring Range 0.5 to 263,000 m³/h (2.5 to 1,665,000 gal/min) 
Max. Measurement Error Volume flow: ±0.5% o.r. ± 1 mm/s (0.04 in/s) 
Medium Temperature (PTFE) -20°C to +90°C (-4°F to +194°F) 
Ambient Temperature -40°C to +60°C (-40°F to +140°F) 
Max. Process Pressure PN 40, Class 300, 20K 
Electrical Conductivity ≥ 5 µS/cm for liquids 
Wetted Materials Electrodes: 1.4435 (316L); Liner: PTFE 
Output Signal 4-20 mA HART (active/passive), pulse/frequency/switch 
Power Supply 24V DC 
Housing Material Polycarbonate; AlSi10Mg, coated 
Protection Rating IP66/67 standard; IP68 optional (Type 6P) 
Digital Communication HART, Modbus RS485 
Certifications Drinking water: ACS, NSF 61, WRAS; Hazardous area: CSA, GP, KC; CRN, PED 

Applications

  • Water & Wastewater: Raw water intake, drinking water distribution, effluent monitoring, and treatment processes 

  • Industrial Utilities: Cooling water circuits, process water supply, and utility monitoring

  • Municipal Infrastructure: Potable water systems requiring drinking water certifications 

  • General Industry: Basic flow measurement tasks where ±0.5% accuracy is sufficient

  • Harsh Environments: Underground or underwater installations with IP68 and corrosion protection 

Why Choose the Endress+Hauser Promag W 10?

  • Reliable Measurement: Zero inlet run requirement ensures accurate readings even in tight spaces; no pressure loss 

  • Flexible Installation: Fixed or lap-joint process connections adapt to various piping configurations 

  • Application Fitness: EN ISO 12944 corrosion protection enables underground or underwater installation 

  • Easy Commissioning: Guided parameterization with mobile devices via SmartBlue app or touch screen display 

  • Integrated Verification: Heartbeat Technology enables on-demand diagnostics and compliance validation 

  • Global Approvals: International drinking water certifications (NSF 61, ACS, WRAS) enable worldwide deployment 


    Endress+Hauser Proline Promag W 10 electromagnetic flowmeter, model 5WBB1H-AADAEBKA0AUA120AA1. ±0.5% accuracy, HART, PTFE liner, DN25-3000, IP68, for water/wastewater.

 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd