Endress+Hauser Proline Promag W 10 Electromagnetic Flowmeter (5WBB1H-AADAEBKA0AUA120AA1)
- Product Name:Endress+Hauser Proline Promag W 10 Electromagnetic Flowmeter (5WBB1H-AADAEBKA0AUA120AA1)
- Product Number:5WBB1H-AADAEBKA0AUA120AA1
- Brand:Endress+Hauser
- Views:1
-
Endress+Hauser Proline Promag W 10 Electromagnetic Flowmeter (5WBB1H-AADAEBKA0AUA120AA1)
的详细介绍
Endress+Hauser Proline Promag W 10 Electromagnetic Flowmeter
(Order Code: 5WBB1H-AADAEBKA0AUA120AA1)

Endress+Hauser 5WBB1H-AADAEBKA0AUA120AA1 | Proline Promag W 10 Electromagnetic Flowmeter
The Endress+Hauser 5WBB1H-AADAEBKA0AUA120AA1 is a Proline Promag W 10 electromagnetic flowmeter designed for basic water and wastewater applications requiring reliable, maintenance-free flow measurement . This Fundamental series device simplifies every step from engineering to servicing while delivering Endress+Hauser's proven quality and Heartbeat Technology for integrated verification .
Key Features and Product Highlights
-
±0.5% Measurement Accuracy: Standard volume flow accuracy of ±0.5% o.r. ± 1 mm/s (0.04 in/s) for reliable process control
-
Zero Inlet Run Requirement: Reliable measurement at constant accuracy with 0 x DN inlet run without pressure loss, simplifying installation in space-constrained locations
-
Wide Size Range: Available from DN 25 to 3000 (1 to 120 inches), accommodating diverse pipe sizes
-
Heartbeat Technology: Integrated verification enables on-demand diagnostics and compliance validation without process interruption
-
International Drinking Water Approvals: Certified for potable water applications with ACS, KTW-BWGL, NSF 61, and WRAS BS 6920 approvals
-
IP68 Protection: Degree of protection IP68 (Type 6P enclosure) with EN ISO 12944 corrosion protection for underground or underwater installation
Order Code Interpretation: 5WBB1H-AADAEBKA0AUA120AA1
Based on Endress+Hauser's Proline Promag W 10 ordering structure , this specific configuration includes:
| Position(s) | Code | Interpretation |
|---|---|---|
| 1-5 | 5WBB1H | Promag W 10, DN25-3000, PTFE liner option |
| 6 | A | Approval: Non-hazardous area |
| 7 | A | Process connection: Lap joint flange |
| 8 | D | Transmitter: Enhanced functionality |
| 9 | A | Power supply: 24V DC |
| 10 | E | Output: 4-20mA HART + pulse/frequency/switch |
| 11 | B | Display: Without local display; configurable via communication |
| 12 | K | Housing: Compact, aluminum coated |
| 13 | A | Sensor connection: Standard |
| 14 | 0 | Electrical connection: Cable gland M20 |
| 15 | A | Liner: PTFE |
| 16 | U | Process connection material: PN10, stainless steel lap joint flange |
| 17 | A | Electrodes: 1.4435 (316L) stainless steel |
| 18 | 1 | Calibration: 0.5% accuracy |
| 19 | 2 | Device model: 2 |
| 20-21 | 0A | Custom-specific configuration |
| 22-23 | A1 | Additional options |
Technical Specifications

| Parameter | Specification |
|---|---|
| Manufacturer | Endress+Hauser |
| Product Series | Proline Promag W 10 |
| Measuring Principle | Electromagnetic |
| Nominal Diameter | DN 25 to 3000 (1 to 120") |
| Measuring Range | 0.5 to 263,000 m³/h (2.5 to 1,665,000 gal/min) |
| Max. Measurement Error | Volume flow: ±0.5% o.r. ± 1 mm/s (0.04 in/s) |
| Medium Temperature (PTFE) | -20°C to +90°C (-4°F to +194°F) |
| Ambient Temperature | -40°C to +60°C (-40°F to +140°F) |
| Max. Process Pressure | PN 40, Class 300, 20K |
| Electrical Conductivity | ≥ 5 µS/cm for liquids |
| Wetted Materials | Electrodes: 1.4435 (316L); Liner: PTFE |
| Output Signal | 4-20 mA HART (active/passive), pulse/frequency/switch |
| Power Supply | 24V DC |
| Housing Material | Polycarbonate; AlSi10Mg, coated |
| Protection Rating | IP66/67 standard; IP68 optional (Type 6P) |
| Digital Communication | HART, Modbus RS485 |
| Certifications | Drinking water: ACS, NSF 61, WRAS; Hazardous area: CSA, GP, KC; CRN, PED |
Applications
-
Water & Wastewater: Raw water intake, drinking water distribution, effluent monitoring, and treatment processes
-
Industrial Utilities: Cooling water circuits, process water supply, and utility monitoring
-
Municipal Infrastructure: Potable water systems requiring drinking water certifications
-
General Industry: Basic flow measurement tasks where ±0.5% accuracy is sufficient
-
Harsh Environments: Underground or underwater installations with IP68 and corrosion protection
Why Choose the Endress+Hauser Promag W 10?
-
Reliable Measurement: Zero inlet run requirement ensures accurate readings even in tight spaces; no pressure loss
-
Flexible Installation: Fixed or lap-joint process connections adapt to various piping configurations
-
Application Fitness: EN ISO 12944 corrosion protection enables underground or underwater installation
-
Easy Commissioning: Guided parameterization with mobile devices via SmartBlue app or touch screen display
-
Integrated Verification: Heartbeat Technology enables on-demand diagnostics and compliance validation
-
Global Approvals: International drinking water certifications (NSF 61, ACS, WRAS) enable worldwide deployment
Endress+Hauser Proline Promag W 10 electromagnetic flowmeter, model 5WBB1H-AADAEBKA0AUA120AA1. ±0.5% accuracy, HART, PTFE liner, DN25-3000, IP68, for water/wastewater.