Current Location: Home> Product Class> Endress+Hauser>

Endress+Hauser Prosonic FMU90-R12CA131AA3A Ultrasonic Level Transmitter

  • Product Name:Endress+Hauser Prosonic FMU90-R12CA131AA3A Ultrasonic Level Transmitter
  • Product Number:FMU90-R12CA131AA3A
  • Brand:Endress+Hauser
  • Views:0
你添加了1件商品 查看购物车
简单介绍
The Endress+Hauser Prosonic FMU90-R12CA131AA3A is a versatile, non-contact ultrasonic level transmitter designed for continuous level measurement of liquids, sludge, pastes, and bulk solids, as well as flow measurement in open channels and weirs . This field housing version supports connection of up to 2 FDU9x series ultrasonic sensors and offers integrated pump control, rake control, and limit de

Endress+Hauser Prosonic FMU90-R12CA131AA3A Ultrasonic Level Transmitter

的详细介绍

Endress+Hauser Prosonic FMU90-R12CA131AA3A
 Ultrasonic Level Transmitter

Endress+Hauser Prosonic FMU90-R12CA131AA3A | Ultrasonic Level Transmitter | 45m

The Endress+Hauser Prosonic FMU90-R12CA131AA3A is a versatile, non-contact ultrasonic level transmitter designed for continuous level measurement of liquids, sludge, pastes, and bulk solids, as well as flow measurement in open channels and weirs . This field housing version supports connection of up to 2 FDU9x series ultrasonic sensors and offers integrated pump control, rake control, and limit detection functions .

The Prosonic FMU90 series is part of Endress+Hauser's Xpert selection – specialized products designed for demanding applications requiring advanced functionality and flexibility .

Order Code Breakdown: FMU90-R12CA131AA3A

Based on Endress+Hauser's ordering structure for the Prosonic FMU90 series :

Position Code Interpretation
Approval R Non-hazardous area
Application 1 Level measurement (1 channel)
Housing 2 Field housing, PC, IP66 / NEMA 4x
Operation C Backlit display + keypad (6-line graphic)
Power Supply A 90-253 VAC, 50/60 Hz
Level Input 1 1 sensor (FDU90/91/92/93/95)
Switch Output 3 3 relays (SPDT)
Output 1 1x 0/4-20 mA HART
Additional Input A None
Data Logging A Basic version
Language A English (multi-language available)
Additional Option 3A Extended version (likely includes pump control functions)

Key Features & Benefits

  • High Measurement Accuracy: Delivers ±2 mm + 0.17% of measured distance, ensuring reliable process control 

  • Flexible I/O Configuration: Equipped with 3 SPDT relays and 1x 4-20 mA HART output; optional second analog output available 

  • Integrated Control Functions: Supports pump control, rake control, limit detection, flow monitoring, and up to 6 relays for alarms (optional) 

  • Automatic Sensor Recognition: Auto-detects FDU9x series ultrasonic sensors for plug-and-play operation 

  • User-Friendly Interface: 6-line backlit graphic display with envelope curve display for on-site diagnostics; 15 languages available 

  • Built-in Flow Curves: Pre-programmed linearization for common flumes and weirs; 32-point custom linearization 

  • Remote Diagnostics: Compatible with FieldCare PC software for remote operation, diagnostics, and documentation 

Technical Specifications

Parameter Specification
Manufacturer Endress+Hauser
Product Series Prosonic S FMU90
Measuring Principle Ultrasonic, Time-of-Flight (ToF)
Max. Measurement Range Up to 45 m (148 ft) with FDU9x sensors 
Accuracy ±2 mm + 0.17% of measured distance 
Power Supply 90-253 VAC, 50/60 Hz 
Outputs 1x 4-20 mA HART; 3x SPDT relays 
Housing Material PC (Polycarbonate) 
Protection Rating IP66 / NEMA 4x 
Ambient Temperature -40°C to +60°C (-40°F to +140°F) 
Display 6-line backlit graphic display 
Digital Communication HART; optional PROFIBUS DP 
Sensor Compatibility FDU90, FDU91, FDU92, FDU93, FDU95 
Certifications ATEX, CSA, IECEx (depending on sensor combination) 

Applications

  • Water & Wastewater Treatment: Level monitoring in storage tanks, pump stations, lift stations, and clarifiers 

  • Open Channel Flow Measurement: Flow monitoring in weirs and flumes with pre-programmed flow curves 

  • Stormwater Overflow Basins: Simultaneous level and flow measurement with a single sensor 

  • Bulk Solids: Level monitoring of powdery to coarse bulk materials in silos and hoppers 

  • Pump Control: Alternating pump control, dry-run protection, and rake control functions 

  • Industrial Processes: Level and flow monitoring in chemical, food, and mining industries

Prosonic FMU90-R12CA131AA3A

  • Xpert Selection: Specialized product designed for demanding applications requiring advanced functionality 

  • Field-Proven Reliability: IP66/NEMA 4x housing with corrosion-resistant materials ensures durability in harsh environments

  • Built-in Intelligence: Integrated pump control, flow calculation, and limit detection reduce external control hardware

  • Easy Commissioning: Automatic sensor recognition and intuitive menu guidance with 6-line display 

  • Global Support: Backed by Endress+Hauser's worldwide service network

  • Comprehensive Diagnostics: On-site envelope curve display enables quick troubleshooting 


Q&A

Q1: What is the maximum measurement range of the FMU90-R12CA131AA3A?


A: The maximum measurement range depends on the connected FDU9x sensor. With compatible sensors, the Prosonic FMU90 can measure up to 45 meters (148 feet) for liquids and bulk solids . The device automatically recognizes FDU90/91/92/93/95 sensors, each with different range capabilities optimized for specific applications .


Q2: What control functions are integrated into this transmitter?


A: The FMU90 includes built-in pump control functions (alternating pumps, dry-run protection), rake control, limit detection, and flow monitoring . The R12CA131AA3A configuration includes 3 SPDT relays, with the option to expand up to 6 relays for additional alarm or control functions . Pre-programmed flow curves for standard weirs and flumes enable direct flow measurement without external calculation units .


Q3: How accurate is the Prosonic FMU90 for level measurement?


A: The Prosonic FMU90 delivers a reference accuracy of ±2 mm + 0.17% of the measured distance . For example, at a 10 m measurement distance, the accuracy would be approximately ±2 mm + 17 mm = ±19 mm (0.75 inches). The device includes integrated temperature compensation to automatically correct for sound velocity variations caused by temperature changes, ensuring consistent accuracy across different operating conditions 


Endress+Hauser Prosonic FMU90-R12CA131AA3A ultrasonic level transmitter. 4-20mA HART, IP66, ±2mm accuracy, up to 45m range, pump control, for water/wastewater.

 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd