Endress+Hauser Proline Prowirl F 200 Vortex Flowmeter (Order Code: 7F2C80-AAACCADAAAAAASKA1+LA)
- Product Name:Endress+Hauser Proline Prowirl F 200 Vortex Flowmeter (Order Code: 7F2C80-AAACCADAAAAAASKA1+LA)
- Product Number:7F2C80-AAACCADAAAAAASKA1+LA
- Brand:Endress+Hauser
- Views:4
-
Endress+Hauser Proline Prowirl F 200 Vortex Flowmeter (Order Code: 7F2C80-AAACCADAAAAAASKA1+LA)
的详细介绍
Endress+Hauser Proline Prowirl F 200 Vortex Flowmeter
(Order Code: 7F2C80-AAACCADAAAAAASKA1+LA)


The Endress+Hauser 7F2C80-AAACCADAAAAAASKA1+LA is a Proline Prowirl F 200 vortex flowmeter with a DN80 (3-inch) nominal diameter. This multivariable flowmeter is the preferred choice for measuring wet, saturated, and superheated steam, as well as gases and liquids (including cryogenic applications). It features integrated temperature and pressure measurement for energy management and Heartbeat Technology for continuous verification without process interruption.
Order Code Interpretation: 7F2C80-AAACCADAAAAAASKA1+LA
Based on Endress+Hauser's ordering structure for the Proline Prowirl F 200 series:
| Position | Code | Interpretation |
|---|---|---|
| 1-5 | 7F2C80 | Prowirl F 200, DN80 (3"), Vortex flowmeter |
| 6-7 | AA | Approval: Non-hazardous area |
| 8-9 | AC | Power supply; Output: 4-20mA HART |
| 10 | C | Display: 4-line backlit with touch control |
| 11 | A | Housing: Compact, AlSi10Mg coated |
| 12-17 | DAAAAAA | Sensor version; Process connection; Calibration |
| 18-21 | SKA1 | Material; Additional options |
| 22-23 | +LA | Additional option: Basic version |
Key Features & Benefits
-
Multivariable Measurement: Measures volume flow, mass flow, energy flow, heat flow difference, and temperature in a single device. Integrated temperature and pressure sensors for steam and gas applications.
-
Wet Steam Detection: Inline wet steam measurement capability for DN 25 to 300 (1 to 12"). Detects and quantifies wet steam conditions, ensuring accurate energy management.
-
Heartbeat Technology: Integrated verification enables continuous self-diagnostics and on-demand compliance testing without process interruption. TÜV SÜD-attested compliance with ISO 9001:2015 measurement traceability requirements.
-
High Accuracy & Linearity: Consistent accuracy down to Reynolds number 10,000—the most linear vortex meter body. Volume flow accuracy: ±0.75% (liquid), ±1.00% (steam/gas); optional ±0.65%.
-
Wide Temperature & Pressure Range: Medium temperature from -200°C to +400°C (option) and process pressure up to PN 100, Class 600, 20K.
-
Long-Term Stability: Robust drift-free capacitive sensor ensures reliable performance over extended periods.
-
Space-Saving Design: Inlet run compensation minimizes required straight pipe lengths before the meter.
-
Flexible Communication: 4-20mA HART (as configured) with optional PROFIBUS PA and FOUNDATION Fieldbus.
-
Global Approvals: SIL, hazardous area (ATEX, IECEx), marine (ABS, LR, BV, DNV), and PED/CRN pressure certifications
Technical Specifications
| Parameter | Speification |
|---|---|
| Manufacturer | Endress+Hauser |
| Product Series | Proline Prowirl F 200 |
| Order Code | 7F2C80-AAACCADAAAAAASKA1+LA |
| Nominal Diameter | DN 80 (3") |
| Measuring Principle | Vortex flowmeter (ISO 12764 compliant) |
| Media | Wet/saturated/superheated steam, gases, liquids (including cryogenic) |
| Max. Measurement Error (Liquid) | Volume flow: ±0.75% (optional ±0.65%); Mass flow: ±0.85% |
| Max. Measurement Error (Steam/Gas) | Volume flow: ±1.00%; Mass flow (saturated steam): ±1.7% (temp comp.) |
| Measuring Range (Liquid) | 0.2 to 2100 m³/h (0.15 to 1520 ft³/min) |
| Measuring Range (Steam/Gas) | 1.5 to 28,000 m³/h (0.9 to 16,600 ft³/min) |
| Medium Temperature | Standard: -40 to +260°C; Option: -200 to +400°C |
| Max. Process Pressure | PN 100, Class 600, 20K |
| Wetted Materials | Measuring tube: 1.4408 (CF3M); DSC sensor: 1.4404 (316/316L); Alloy C22 option |
| Output Signal | 4-20 mA HART (passive) |
| Digital Communication | HART (as configured) |
| Power Supply | DC 12 to 35 V (4-20 mA HART) |
| Housing Material | Transmitter: AlSi10Mg coated; Sensor connection: AlSi10Mg coated or 1.4408 |
| Ingress Protection | IP66/67, NEMA Type 4X |
| Display/Operation | 4-line backlit display with touch control (operation without opening device) |
| Certifications | ATEX, IECEx, cCSAus, SIL, Marine (ABS, LR, BV, DNV), PED, CRN, NACE |
Proline Prowirl F 200 7F2C80
-
Preferred Steam Flowmeter: Optimized for all steam types—wet, saturated, and superheated.
-
Best-in-Class Accuracy: Consistent accuracy down to Re 10,000 with optional PremiumCal.
-
Heartbeat Technology: Integrated verification reduces maintenance costs and extends calibration intervals.
-
Multivariable Measurement: Combines flow, temperature, and pressure in one device—no separate instruments needed.
-
Global Approvals: SIL, hazardous area, marine, and pressure certifications for worldwide deployment.
-
Long-Term Stability: Drift-free capacitive sensor ensures reliable performance over decades.
-
Easy Operation: Touch control display allows safe configuration without opening the housing

FAQs
Q1: What is the maximum temperature range for the Proline Prowirl F 200 7F2C80?
A: The standard version operates from -40°C to +260°C. An optional high/low temperature version extends the range to -200°C to +400°C, suitable for cryogenic applications and high-temperature steam processes.
Q2: Can the Prowirl F 200 measure wet steam accurately?
A: Yes. The Prowirl F 200 is specifically designed with inline wet steam detection capability for DN 25 to 300 (1 to 12") sizes. It can detect and quantify wet steam conditions, making it the preferred flowmeter for all steam applications—wet, saturated, or superheated.
Q3: What is Heartbeat Technology and how does it benefit my plant?
A: Heartbeat Technology provides continuous self-diagnostics, predictive maintenance recommendations, and on-demand verification of the entire measuring point without process interruption. It is TÜV SÜD-attested for ISO 9001:2015 measurement traceability, helping optimize maintenance schedules, reduce unplanned downtime, and comply with quality standards