- Siemens
- ABB
-
A-B
- MTL
- Pepperl Fuchs
- Phoenix
- Weidmuller
-
IFM
-
Hirschman
-
Hach
-
Schneider
- Norgren
- Fluke
- Sick
- Moxa
- Honeywell
- Yokogawa
- Rosemount
- Emerson
- Beamex
- Festo
- Oring
- Danfoss
- Rotork YTC
- Atlas Copco
-
Allen Bradley
-
YASKAWA
- Triconex
-
Endress+Hauser
-
Dungs
- Belimo
-
Jaquet
-
WIKA
-
UE
- Foxboro
- SMC
-
bifold
-
Nagano Keiki
-
AIRTAC
-
Dynisco
-
proface
-
Woodward
-
CPC
-
Durag
-
Crowcon
-
Bently Nevada
- Krohne
- York
- Bray
-
B&R
- MSA
- AZBIL
- Omron
-
PEPPER+FUCHS
-
MEANWELL
- GE
- XECRO
-
KONAN
-
Fairford
-
testo
-
Emotron
- PR electronics
MTL Safety Barrier Solenoid / Alarm Drive MTL4523V/VL – MTL5523V/VL
MTL Safety Barrier Solenoid / Alarm Drive MTL4523V/VL – MTL5523V/VL
MTL Safety Barrier Solenoid / Alarm Drive MTL4523V/VL – MTL5523V/VL
MTL Safety Barrier Solenoid / Alarm Drive MTL4523V/VL – MTL5523V/VL
Description
With the MTLx523V/VL interface, an on/off device in a hazardous area can be controlled by a voltage signal in the safe area. It is suitable for driving loads such as solenoids. Line fault detection (LFD), which operates irrespective of the output state, is signalled by a safe-area solid-state switch which energises if a field line is open or short–circuited. Earth fault detection can be provided by connecting an MTL4220 earth leakage detector to terminal 3.
MTL Safety Barrier Solenoid / Alarm Drive MTL4523V/VL – MTL5523V/VL
Specification
Hazardous-area output (MTLx523V)
Minimum output voltage: 13.6V at 48mA
Maximum output voltage: 24V from 180Ω
Maximum off-state output voltage: 4V from 180Ω
Current limit: 48mA minimum
Hazardous-area output (MTLx523VL)
Minimum output voltage: 11.1V at 48mA
Maximum output voltage: 24V from 232Ω
Maximum off-state output voltage: 4V from 232Ω
Current limit: 48mA minimum
Output ripple
< 0.5% of maximum output, peak to peak
Control input
Suitable for 24V logic drive
Output turns on if > 18V applied across control input
Output turns off if < 5V applied across control input
Maximum control input voltage: 28V
Maximum control system output leakage current: 0.5mA
Response time
Output within 10% of final value within 100ms
MTL Safety Barrier Solenoid / Alarm Drive MTL4523V/VL – MTL5523V/VL

MTL Safety Barrier Solenoid / Alarm Drive MTL4523V/VL – MTL5523V/VL