Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G

  • Product Name:Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G
  • Product Number:ZR22G, ZR22S, ZR402G, ZR22P, ZR22R, ZR22V, AC1, MC
  • Brand:Yokogawa
  • Views:965
你添加了1件商品 查看购物车
简单介绍
Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G/ZR402G Yokogawa Oxygen Analyzer ZR22G/ZR402G Models: ZR22G, ZR22S, ZR402G, ZR22P, ZR22R, ZR22V, AC1, MC1, M1233SR, IAC-24, WZ-H, M1234SE-A, M1200DB-06

Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G

的详细介绍

Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G

 


Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G/ZR402G

Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G 

Models: ZR22G, ZR22S, ZR402G, ZR22P, ZR22R, ZR22V, AC1, MC1, M1233SR, IAC-24, WZ-H, M1234SE-A, M1200DB-06

 

Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G

Description

Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G/ZR402G

Yokogawa Oxygen Analyzer ZR22G/ZR402G

Yokogawa's zirconia oxygen analyzers are used for combustion monitoring and control in a wide variety of applications and help industries to make considerable achievements in energy saving. The applications range from energy-consuming industries, such as iron and steel, electric power, oil and petrochemical, ceramics, pulp and paper, food, and textiles, to various combustion facilities, such as incinerators and small- and medium sized boilers. Combustion monitoring and control using the analyzer also contribute to a lowering of CO2, SOx, and NOx emissions by allowing for more complete combustion, thus preventing global warming and air pollution.

 

Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G/ZR402G

Yokogawa Oxygen Analyzer ZR22G/ZR402G features include:


1)The separate type converter ZR402G incorporates a LCD touchscreen for ease of operation.

2)The built-in heater assembly of the probe can be replaced on site, reducing maintenance costs (ZR22G only).

3)The probe uses a long-life, high-reliability, field replacable Zirconia sensor.

4) Remote maintenance using digital communications (HART) reduces maintenance costs.

Note: HART is a registered trademark of HART Communication Foundation.

 

Measurement object

Oxygen concentration in combustion exhaust gas and mixed gas

Measurement system

Zirconium oxide sensor

Measurement range

0.01 to 100 vol% O2

Output signal

4 to 20 mA DC, two points (ZR402G) (maximum load resistance 550Ω)

Setting range

Any setting in the range of 0 - 5 vol%O2 to 0 - 100 vol%O2 (in 1 vol% O2), or partial range

Digital communication (HART)

250 to 550Ω, depending on number of field devices connected to the loop (multi-drop mode)

Sample gas pressure

-5 to +250 kPa (Pressure compensation option necessary over +5 kPa)

Sample gas temperature

0 to 700℃ (Probe only)
700 to 1871℃ (with 0.15m probe with JIS 5K 32 FF flange and ZR22P High Temperature Probe Adapter)

Probe length

0.15, 0.4, 0.7, 1.0, 1.5, 2.0, 2.5, 3.0, 3.6, 4.2, 4.8, 5.4 m

Contact output

Four points (one is fail-safe, normally open)

Contact input

Two points

Calibration

Method; zero/span calibration
Calibration mode; automatic, semi-automatic and manual (with an LCD touchscreen)

Construction of detector (ZR22G)

Heater and thermocouple replaceable construction. 
Non-explosion-proof. Equivalent to NEMA4X/IP66

Construction of converter (ZR402G)

Non-explosion-proof, outdoor installation, equivalent to NEMA4X/IP66

Ambient Temperature

Probe (ZR22G): -20 to 150℃
Converter (ZR402G): -20 to 55℃)

Reference Gas System

Instrument Air (preferred): 50 kPa (200 kPa with check valve) + the pressure inside the furnace; Approx. 1 Nl/min consumption

Natural convection

Power supply

85 to 264 V AC; 45 to 66 Hz

 

Accuracy

Repeatability

±0.5% Maximum value of set range

Linearity

±1% Maximum value of set range

Drift

±2% Maximum value of set range/month

Response time (T90)

90% response within 5 sec (60 sec for explosion-proof ZR22S)


Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G/ZR402G

Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G

Models: ZR22G, ZR22S, ZR402G, ZR22P, ZR22R, ZR22V, AC1, MC1, M1233SR, IAC-24, WZ-H, M1234SE-A, M1200DB-06

ZR22G-100-S-A-C-T-T-E-A

ZR22G-040-S-A-E-T-T-E-A/CV

ZR402G-T-E-E-A

ZR22G-040-S-A-E-T-T-E-A 

ZR22G-070-S-A-E-T-T-E-A/CV

ZR402G-T-E-E-A/SCT

ZR40H-T-T-A

K9473XJ

K9471UA

ZR22G- 070-S-A-E-T-T-E-A  

ZR402G- T-E-E-A

ZR402G-T-E-E-A

ZR22G-070-S-A-E-T-T-E-A/CV

X9473XJ

ZR22G-070-S-A-E-T-T-E-A

ZR402G-M-E-E-A/SCT

ZR22G-150-S-A-E-T-M-E-A/SCT

ZR22G-040-S-A-C-T-T-E-A/ SCT

ZR22G-040-S-A-C-T-T-E-A/SCT

ZR22G-040-S-A-E-T-T-E-A/CV

ZR402G-T-E-E-A

K9473XG

ZR40H-T-T-A

ZR22G-040-S-A-C-T-T-E-A

ZR22G-100-S-C-T-T-E-A/CV

ZR402G-M-E-E-A

ZR40H-T-T-A

ZR402G-M-E-E-A/H/SCT

ZR22G-040-C-C-C-T-T-E-A

ZR40H-T-T-A

ZR22G-040-S-A-C-T-T-E-A

ZR402G-T-E-E-A

ZR22G-070-S-A-E-T-T-E-A

ZR22G-070-S-A-E-T-T-E-A/CV/F1/SCT

ZR22G-100-S-A-E-T-M-E-A/CV/SCT,

ZR402G-M-E-E-A/SCT,
ZA8F-A,

K9473XK,

G7001ZC,

G7014XF,

E7044KF,

ZR22G-100-S-B-E-T-T-E-A/CV/SCT

ZR40H-T-T-A

ZR22G-100-S-A-E-T-M-E-A/CV/SCT/F1
ZO21R-L-100-J-B

ZR402G-M-E-E-A/SCT  
ZR22G-100-S-A-E-T-M-E-A/CV/SCT/F1 
ZA8F-A                                                     
K9473XK                                              

ZR22G-070-S-C-E-R-P-E-A/CV

ZR402G-P-E-E-A/SCT/C3

ZO21S-7-E-A

E7050BA

G7016XH

ZR22G-015-S-Q-C-R-M-E-A/SCT

ZR22G-040-S-K-C-T-M-E-A

ZO21P-H-A-100-E*B

E7046EC

ZR402G-T-E-E-A

ZR22G-040-S-B-C-T-T-E-A

Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G

 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd