Yokogawa oxygen analyzer ZR22G

  • Product Name:Yokogawa oxygen analyzer ZR22G
  • Product Number:ZR22G
  • Brand:Yokogawa
  • Views:3351
你添加了1件商品 查看购物车
简单介绍
Yokogawa oxygen analyzer ZR22G Yokogawa oxygen analyzer ZR22G Yokogawa oxygen analyzer ZR22G

Yokogawa oxygen analyzer ZR22G

的详细介绍

Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G

 

Yokogawa oxygen analyzer ZR22G

Models: ZR22G, ZR22S, ZR402G, ZR22P, ZR22R, ZR22V, AC1, MC1, M1233SR, IAC-24, WZ-H, M1234SE-A, M1200DB-06

 

Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G

Description

Yokogawa oxygen analyzer ZR22G

Yokogawa Oxygen Analyzer ZR22G/ZR402G

Yokogawa's zirconia oxygen analyzers are used for combustion monitoring and control in a wide variety of applications and help industries to make considerable achievements in energy saving. The applications range from energy-consuming industries, such as iron and steel, electric power, oil and petrochemical, ceramics, pulp and paper, food, and textiles, to various combustion facilities, such as incinerators and small- and medium sized boilers. Combustion monitoring and control using the analyzer also contribute to a lowering of CO2, SOx, and NOx emissions by allowing for more complete combustion, thus preventing global warming and air pollution.

 

Yokogawa oxygen analyzer ZR22G

Yokogawa Oxygen Analyzer ZR22G/ZR402G features include:


1)The separate type converter ZR402G incorporates a LCD touchscreen for ease of operation.

2)The built-in heater assembly of the probe can be replaced on site, reducing maintenance costs (ZR22G only).

3)The probe uses a long-life, high-reliability, field replacable Zirconia sensor.

4) Remote maintenance using digital communications (HART) reduces maintenance costs.

Note: HART is a registered trademark of HART Communication Foundation.

 

Measurement object

Oxygen concentration in combustion exhaust gas and mixed gas

Measurement system

Zirconium oxide sensor

Measurement range

0.01 to 100 vol% O2

Output signal

4 to 20 mA DC, two points (ZR402G) (maximum load resistance 550Ω)

Setting range

Any setting in the range of 0 - 5 vol%O2 to 0 - 100 vol%O2 (in 1 vol% O2), or partial range

Digital communication (HART)

250 to 550Ω, depending on number of field devices connected to the loop (multi-drop mode)

Sample gas pressure

-5 to +250 kPa (Pressure compensation option necessary over +5 kPa)

Sample gas temperature

0 to 700℃ (Probe only)
700 to 1871℃ (with 0.15m probe with JIS 5K 32 FF flange and ZR22P High Temperature Probe Adapter)

Probe length

0.15, 0.4, 0.7, 1.0, 1.5, 2.0, 2.5, 3.0, 3.6, 4.2, 4.8, 5.4 m

Contact output

Four points (one is fail-safe, normally open)

Contact input

Two points

Calibration

Method; zero/span calibration
Calibration mode; automatic, semi-automatic and manual (with an LCD touchscreen)

Construction of detector (ZR22G)

Heater and thermocouple replaceable construction. 
Non-explosion-proof. Equivalent to NEMA4X/IP66

Construction of converter (ZR402G)

Non-explosion-proof, outdoor installation, equivalent to NEMA4X/IP66

Ambient Temperature

Probe (ZR22G): -20 to 150℃
Converter (ZR402G): -20 to 55℃)

Reference Gas System

Instrument Air (preferred): 50 kPa (200 kPa with check valve) + the pressure inside the furnace; Approx. 1 Nl/min consumption

Natural convection

Power supply

85 to 264 V AC; 45 to 66 Hz

 

Accuracy

Repeatability

±0.5% Maximum value of set range

Linearity

±1% Maximum value of set range

Drift

±2% Maximum value of set range/month

Response time (T90)

90% response within 5 sec (60 sec for explosion-proof ZR22S)


Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G/ZR402G

Yokogawa oxygen analyzer ZR22G

Models: ZR22G, ZR22S, ZR402G, ZR22P, ZR22R, ZR22V, AC1, MC1, M1233SR, IAC-24, WZ-H, M1234SE-A, M1200DB-06

ZR22G-100-S-A-C-T-T-E-A

ZR22G-040-S-A-E-T-T-E-A/CV

ZR402G-T-E-E-A

ZR22G-040-S-A-E-T-T-E-A 

ZR22G-070-S-A-E-T-T-E-A/CV

ZR402G-T-E-E-A/SCT

ZR40H-T-T-A

K9473XJ

K9471UA

ZR22G- 070-S-A-E-T-T-E-A  

ZR402G- T-E-E-A

ZR402G-T-E-E-A

ZR22G-070-S-A-E-T-T-E-A/CV

X9473XJ

ZR22G-070-S-A-E-T-T-E-A

ZR402G-M-E-E-A/SCT

ZR22G-150-S-A-E-T-M-E-A/SCT

ZR22G-040-S-A-C-T-T-E-A/ SCT

ZR22G-040-S-A-C-T-T-E-A/SCT

ZR22G-040-S-A-E-T-T-E-A/CV

ZR402G-T-E-E-A

K9473XG

ZR40H-T-T-A

ZR22G-040-S-A-C-T-T-E-A

ZR22G-100-S-C-T-T-E-A/CV

ZR402G-M-E-E-A

ZR40H-T-T-A

ZR402G-M-E-E-A/H/SCT

ZR22G-040-C-C-C-T-T-E-A

ZR40H-T-T-A

ZR22G-040-S-A-C-T-T-E-A

ZR402G-T-E-E-A

ZR22G-070-S-A-E-T-T-E-A

ZR22G-070-S-A-E-T-T-E-A/CV/F1/SCT

ZR22G-100-S-A-E-T-M-E-A/CV/SCT,

ZR402G-M-E-E-A/SCT, 
ZA8F-A,

K9473XK,

G7001ZC,

G7014XF,

E7044KF,

ZR22G-100-S-B-E-T-T-E-A/CV/SCT

ZR40H-T-T-A

ZR22G-100-S-A-E-T-M-E-A/CV/SCT/F1
ZO21R-L-100-J-B

ZR402G-M-E-E-A/SCT   
ZR22G-100-S-A-E-T-M-E-A/CV/SCT/F1  
ZA8F-A                                                      
K9473XK                                              

ZR22G-070-S-C-E-R-P-E-A/CV

ZR402G-P-E-E-A/SCT/C3

ZO21S-7-E-A

E7050BA

G7016XH

ZR22G-015-S-Q-C-R-M-E-A/SCT

ZR22G-040-S-K-C-T-M-E-A

ZO21P-H-A-100-E*B

E7046EC

ZR402G-T-E-E-A

ZR22G-040-S-B-C-T-T-E-A

Yokogawa oxygen analyzer ZR22G

 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd