Yokogawa YTA610 Temperature Transmitter YTA610-FA2A4DB/X2/KU25

  • Product Name:Yokogawa YTA610 Temperature Transmitter YTA610-FA2A4DB/X2/KU25
  • Product Number:YTA610-FA2A4DB/X2/KU25
  • Brand:Yokogawa
  • Views:186
你添加了1件商品 查看购物车
简单介绍
Yokogawa YTA610 Temperature Transmitter YTA610-FA2A4DB/X2/KU25 Yokogawa YTA610 Temperature Transmitter YTA610-FA2A4DB/X2/KU25 Yokogawa YTA610 Temperature Transmitter YTA610-FA2A4DB/X2/KU25

Yokogawa YTA610 Temperature Transmitter YTA610-FA2A4DB/X2/KU25

的详细介绍

Yokogawa YTA610 Temperature Transmitter YTA610-FA2A4DB/X2/KU25



Yokogawa YTA610 Temperature Transmitter YTA610-FA2A4DB/X2/KU25

Description

The YTA610 provides high accuracy, stability, and reliability. The housing structure adopts reliable dual-compartment structure. The sensor input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20 mA DC analog signal or Fieldbus digital signal. HART® 7 Protocol or FOUNDATION™ Fieldbus ITK 6 version are available. The dual input can accept two sensors calculation of the differential or average value and the sensor backup function. Sensor backup functions for automatically switches-over from the primary to the backup upon sensor failure.
By adoption of local parameter switch on the Indicator, it becomes easy to do the on-site setting work.

Yokogawa YTA610 Temperature Transmitter YTA610-FA2A4DB/X2/KU25
YTA610 features include:

Dual-compartment field-mount housing

Choice of HART® 7, or FOUNDATION™ Fieldbus ITK 6 Protocol

Local Parameter Setting function (Indicator model)

Basic diagnosis

 

Accuracy

The YTA610 enables advanced linearization of 21 types of industrial temperature sensors and input signals. The A/D accuracy of the representative Pt100 sensor is 0.14. Analog D/A accuracy of the output is 0.03%.

Sensors and Inputs

The YTA610 has 4 to 20 mA analogue output signal with HART® 7 digital protocol or full digital FOUNDATION™ Fieldbus protocol.

 

Dual sensor input

The YTA610 in capable of dual sensor input. With the processing capability of the transmitter, this dual input can be used to provide Failed Sensor Backup, Temperature Averaging, or Differential Temperature measurement.


Yokogawa YTA610 Temperature Transmitter YTA610-FA2A4DB/X2/KU25

Model and Suffix Codes

Yokogawa YTA610 Temperature Transmitter

Model

Suffix Codes

Description

YTA610

. . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . .

Temperature Transmitter

Output signal

-J . . . . . . . . . . . . . . .. .

-F . . . . . . . . . . . . . . . ..

4 to 20 mA DC with digital communication HART 7protocol

Digital communication (FOUNDATION Fieldbus protocol)

A . . . . . . . . . . . . . ..

Always A

Sensor input

1 . . . . . . . . . . . .

2 . . . . . . . . . . .. 

Single

Double

Housing code

A . . . . . . . . . .

C . . . . . . . . . ..

Aluminum

Stainless

Electrical connection

0 . . . . . . . .

2 . . . . . . . .

4 . . . . . . . .

G1/2 female

1/2 NPT female

M20 female

Integral indicator

D . . . . .

N . . . . . 

Digital indicator with Local Operating Switch

None

Mounting bracket

B . . .

D . . . .

J . . . .

K . . ..  

N. . . 

SUS304 stainless steel 2-inch horizontal pipemountin bracke *1

SUS304 stainless steel 2-inch vertical pipe mounting bracket

SUS316 stainless steel 2-inch horizontal pipemountin bracke *1

SUS316 stainless steel 2-inch vertical pipe mounting bracket

None

Option codes

/o Optional specification

Yokogawa YTA110 Temperature Transmitter

Yokogawa YTA310 Temperature Transmitter

Yokogawa YTA320 Temperature Transmitter

Yokogawa YTA610 Temperature Transmitter

Yokogawa YTA710 Temperature Transmitter

Yokogawa YTA50 Temperature Transmitter

Yokogawa YTA70 Temperature Transmitter

Yokogawa YTA70P Temperature Transmitter

Yokogawa YTA610 Temperature Transmitter

Yokogawa YTA610 Temperature Transmitter YTA610-FA2A4DB/X2/KU25


Detailed models:

YTA110-EA2DN/KU2
YTA110-EA4DN/KU2
YTA110-EA2DB/KU2
YTA110-EA4DB/X1/N4/KU2 
YTA320-FA4DB/X1/N4/KS25/LC1
YTA320-FA4DK/E1/SU2
YTA310-EA4DK/E1/KU2
YTA110-EA4DDN/KU2/C3
YTA320-FA4DN/KS25
YTA110-EA4DB/D2/KU2
YTA320-FA4DB/D2/KU2
YTA320-EA4DB
YTA320-EA2DN/FU1/A/N4

YTA110-EA4DN/HC/KU2
YTA110-EA4DN/KU2/A/C1/N4
YTA110-EA4DN/KU2/A/C1
YTA110-EA4DN/KU2/A
YTA110-EA4DN/KU2/C1
YTA110-EA4DB 
YTA110-EA2DN
YTA110-EA2DN/KU2
YTA110-EA2DB
YTA110-EA2DB/KU2
YTA110-EA2DJ/KU2/X1/D2
YTA110-EA4ND/KU2
YTA110-EA4DB/KU21
YTA110-EA4DD/HC/KU2
YTA110-EA4DD/KU2
YTA110-EA2DN/HC/KU2
YTA310-FA4DB/KU21
YTA310-EA4DN
YTA310-EA4DN/SU2  
YTA320-FA4DK/KS25/A/D2/E1/N4
YTA310-EA4NN/X1
YTA310-EA4NN/X1/SU2

YTA610-JA1A4DB/KU2
YTA610-JA1A4DN/KU2
YTA610-FA2C4DK/KU25/A/N4
YTA610-JA1A4DD/KU2/X2/A
YTA710-JA1A4DD/KU2
YTA70-J/KS2
YTA70P-JA
YTA70-J
YTA70-J/KS2
YTA70-E/KS2

YTA610-JA1A4DD/KU2
YTA610-JA1A2DN/KU2
YTA610-JA1A4DN/KU2
YTA610-JA1C4DB/KU2
YTA610-JA1A4DK/KU2/A/N4
YTA610-JA1A4DN/KU2
YTA610-JA1A4DN/KU2/A/N4
YTA610-JA1A4DK/KU2/A/N4
YTA610-JA1A4DN/A/N4
YTA610-JA1A4DN
YTA610-JA1A4DN/KU2
YTA610-JA1A4DN
YTA610-JA1A4DN/SU2
YTA610-JA1A4DN/KU2/CM1
YTA610-JA1A4DN/KU2
YTA610-JA1A4DB/KU2
YTA610-JA1A2DN/FU1/A/N4
YTA610-JA1A4DB/KU2
YTA610-JA2C2DN/FU1
YTA610-JA1A2DB
YTA610-JA1A2DB
YTA610-JA1A4DB/X2/KU2
YTA610-JA2A4DB/X2/KU2
YTA610-FA2A4DB/X2/KU25
YTA710-JA1A4DB/X2/KU2
YTA710-FA2A4DB/X2/KU25

 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd