Current Location: Home> Product Class> Woodward>

Woodward Peak 150 Steam Turbine Control

  • Product Name:Woodward Peak 150 Steam Turbine Control
  • Product Number:Peak 150
  • Brand:Woodward
  • Views:329
你添加了1件商品 查看购物车
简单介绍
Woodward Peak 150 Steam Turbine Control Woodward Peak 150 Steam Turbine Control Woodward Peak 150 Steam Turbine Control

Woodward Peak 150 Steam Turbine Control

的详细介绍

Woodward Peak 150 Steam Turbine Control arrived



Woodward Peak 150 Steam Turbine Control arrived

Inputs
Magnetic Pickup Inputs (2):
Two identical inputs, high-signal-selected
Minimum input voltage 1 Vrms, minimum frequency 200 Hz, maximum frequency 15 kHz
Analog Input (1):
Remote Speed Setting signal (4–20 mA or 1–5 Vdc, internal jumper selectable)
Discrete Inputs (8)
Remote (isolated, 5–28 Vdc)

Woodward Peak 150 Steam Turbine Control arrived
 

Woodward Peak 150 Steam Turbine Control arrived

Options:
Raise speed
Lower speed
Emergency stop
Alarm reset
Remote speed set enable
Start
Idle/minimum governor
Select high dynamics or overspeed test
Outputs
Analog Outputs (2):
Actual speed output (scalable, 4–20/0–1 mA)
Configurable readout (scalable, 4–20/0–1 mA)
Options:
Actual speed
Speed setpoint
Actuator output
Remote speed setpoint
Valve ramp value
Actuator Output (1)
4–20 or 0–200 mA (internal jumper selectable)
Relay Outputs (4)
Keypad Switches (6) Options
Raise speed
Lower speed
Emergency trip
Start
Overspeed test
Alarm reset
LED Indicators (6)
Remote speed setting signal status
Shutdown status
MPU #1 status
MPU #2 status
CPU status
Overspeed test status
Woodward Peak 150 Steam Turbine Control arrived

Power Input
Models are available with these input power requirements: 24 Vdc
90–150 Vdc or 88–132 Vac, 47–63 Hz
Maximum power consumption, all models: 38 W
Operating Ambient Temperature
–25 to +65 °C (–13 to +149 °F)
 Storage Ambient Temperature
–40 to +85 °C (–40 to +185 °F)
Humidity
Designed to meet US MIL-STD-810D, Method 507.2, Procedure II, induced, non-hazardous, cycle 5 (fifteen 24-hour cycles, varying 19–75% humidity, over 33–63 °C)
Vibration
US MIL-STD-167, Type 1
Shock
US MIL-STD-810C, Method 516.2, Procedure 1
North American Regulatory Compliance
UL and cUL listed for Class I, Division 2, Groups A, B, C, & D
Dimensions
Width 483 mm (19 inches)
Height 310 mm (12.2 inches)
Depth 105 mm (4.1 inches)
Woodward Peak 150 Steam Turbine Control arrived

 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com