Moxa serial converters ICF-1180I-S-ST-T

  • Product Name:Moxa serial converters ICF-1180I-S-ST-T
  • Product Number:ICF-1180I-S-ST-T
  • Brand:Moxa
  • Views:86
你添加了1件商品 查看购物车
简单介绍
Moxa serial converters ICF-1180I-S-ST-T Moxa serial converters ICF-1180I-S-ST-T Moxa serial converters ICF-1180I-S-ST-T

Moxa serial converters ICF-1180I-S-ST-T

的详细介绍

Moxa serial converters ICF-1180I-S-ST-T

Features and Benefits

  •  Redundant fiber ring with zero recovery time
  •  Examines network-wide fiber communication from a single converter
  •  Auto baudrate detection and data speed of up to 12 Mbps
  •  PROFIBUS fail-safe prevents corrupted datagrams in functioning segments
  •  Alarm by relay output
  •  2 kV galvanic isolation protection
  •  Dual power inputs for redundancy
  •  Extends PROFIBUS transmission distance up to 45 km
  •  Wide-temperature model available for -40 to 75°C environments
  •  Supports Fiber Signal Intensity Diagnosis

Moxa serial converters ICF-1180I-S-ST-T

Introduction
The ICF-1180I industrial PROFIBUS-to-fiber converters are used to convert PROFIBUS signals from copper to optical fiber. The converters are used to extend serial transmission up to 4 km (multi-mode fiber) or up to 45 km (single-mode fiber). The ICF-1180I provides 2 kV isolation protection for the PROFIBUS system and dual power inputs to ensure that your PROFIBUS device will perform uninterrupted.

Fiber Cable Test Function
Fiber-optic cables are usually deployed for long-distance communication. To ensure proper communication across the fiber-optic cables, engineers use fiber sensors. A fiber cable test function through DIP switch adjustments helps ICF-11801 converters eliminate the need to rely on fiber-optic sensors.

This function not only detects fiber communication abnormalities but also validates the format of the received packet. It can also determine which side (Tx or Rx) is causing the problem.

Moxa serial converters ICF-1180I-S-ST-T

Fiber Inverse Function
The ICF-1180I provides a fiber inverse function to choose fiber-optic light ON or light OFF when sending logic signal ‘1’. For default settings, fiber-optic is light OFF when sending logic signal ‘1’; in Fiber Inverse mode, fiber-optic is light ON when sending logic signal ‘1’.

This feature provides greater compatibility when the ICF-1180I converter is integrated with PROFIBUS converters of other manufacturers. Please refer to third-party user manuals when using this feature.

Fiber Link Monitor
The ICF-1180I converters provide a fiber link monitor function to detect the communication errors on either the fiber side or PROFIBUS side. Once there is an error in communication, the corresponding LED will turn red, and the relay alarm will be activated.

Fiber Signal Intensity Diagnosis
In some circumstances, you may need to measure the reception level of the fiber-optic port with a voltmeter, which can be connected while the device is operating (doing so will not affect data transmission). The measurement can be taken with a voltmeter and read on a PLC that uses floating high impedance analog inputs, which allow you to do the following:

Record the incoming optical power for later measurement (e.g., to indicate aging or damage).

Carry out a good/bad test (limit value).

Moxa serial converters ICF-1180I-S-ST-T

If you have any interest, pls feel free to contact me as below

Jackie Ma

HONGKONG XIEYUAN TECH CO., LIMITED

Add:7-A16,Caishen Commercial Plaza,Hangkou Railway Station,Wuhan, China

M:86-15717178751(WhatsApp & Telegram) | T:+86-27-85887732 | F:86-27-85309780 

Email:Jackie@hkxytech.com

 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd