Current Location: Home> Product Class> Pepperl Fuchs>

Pepperl fuchs Inductive sensor NCN3-F25-N4-V1

  • Product Name:Pepperl fuchs Inductive sensor NCN3-F25-N4-V1
  • Product Number:NCN3-F25-N4-V1
  • Brand:Pepperl Fuchs
  • Views:50
你添加了1件商品 查看购物车
简单介绍
Pepperl fuchs Inductive sensor NCN3-F25-N4-V1 Pepperl fuchs Inductive sensor NCN3-F25-N4-V1 Pepperl fuchs Inductive sensor NCN3-F25-N4-V1

Pepperl fuchs Inductive sensor NCN3-F25-N4-V1

的详细介绍

Pepperl fuchs Inductive sensor NCN3-F25-N4-V1

·Direct mounting on standard actuators
·ATEX & IECEX certifications
Pepperl fuchs Inductive sensor NCN3-F25-N4-V1

Technical Data

General specifications
Switching function                                               2 x normally closed (NC)
Output type                                                        NAMUR
Rated operating distance                   sn                3 mm
Installation                                                          flush mountable
Assured operating distance                sa                0 ... 2.43 mm
Actual operating distance                   sr                2.7 ... 3.3 mm typ.
Reduction factor rAl                                             0.52
Reduction factor rCu                                            0.43
Reduction factor r304                                           0.86
Reduction factor rSt37                                          1
Reduction factor rBrass                                         0.54
Output type                                                         2-wire

Nominal ratings
Nominal voltage                               Uo                 8.2 V (Ri approx. 1 kΩ)
Switching frequency                           f                  0 ... 1500 Hz
Hysteresis                                        H                  typ. 5 %
Reverse polarity protection                                     reverse polarity protected
Short-circuit protection                                           yes
Suitable for 2:1 technology                                      yes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detected                                  ≥ 3 mA
Measuring plate detected                                       ≤ 1 mA
Time delay before availability             tv                  ≤ 1 ms
Switching state indicator                                        LED, yellow

Functional safety related parameters

MTTFd                                                                 1010 a
Mission Time (TM)                                                 20 a
Diagnostic Coverage (DC)                                       0 %

Pepperl fuchs Inductive sensor NCN3-F25-N4-V1

Compliance with standards and directives
    Standard conformity
       NAMUR                                                           EN 60947-5-6:2000
                                                                             IEC 60947-5-6:1999
Electromagnetic compatibility                                    NE 21:2007
Standards                                                               EN 60947-5-2:2007
                                                                             EN 60947-5-2/A1:2012
                                                                             IEC 60947-5-2:2007
                                                                             IEC 60947-5-2 AMD 1:2012

Approvals and certificates
   IECEx approval
       Equipment protection level Ga                            IECEx TUN 17.0021X
       Equipment protection level Gb                            IECEx TUN 17.0021X
       Equipment protection level Da                            IECEx TUN 17.0021X
       Equipment protection level Mb                            IECEx TUN 17.0021X

Pepperl fuchs Inductive sensor NCN3-F25-N4-V1
   ATEX approval

Equipment protection level Ga                                    TÜV 99 ATEX 1479 X
Equipment protection level Gb                                    TÜV 99 ATEX 1479 X
Equipment protection level Da                                    TÜV 99 ATEX 1479 X
UL approval cULus Listed, General Purpose
Ordinary Location                                                      E87056
Hazardous Location                                                   E501628
Control drawing                                                        116-0456
CCC approval
   Hazardous Location                                                2020322315002262
NEPSI approval
NEPSI certificate                                                        GYJ19.1410X
Ambient conditions
Ambient temperature                                                 -25 ... 100 °C (-13 ... 212 °F)
Storage temperature                                                     -40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection type                                                         Connector plug
Housing material                                                          PBT
Sensing face                                                               PBT
Degree of protection                                                     IP67

Pepperl fuchs Inductive sensor NCN3-F25-N4-V1

 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd