Current Location: Home> Product Class> Fluke>

Fluke 700PTP-1 Pneumatic Test Pump

  • Product Name:Fluke 700PTP-1 Pneumatic Test Pump
  • Product Number:700PTP
  • Brand:Fluke
  • Views:54
你添加了1件商品 查看购物车
简单介绍
Fluke 700PTP-1 Pneumatic Test Pump Fluke 700PTP-1 Pneumatic Test Pump Fluke 700PTP-1 Pneumatic Test Pump

Fluke 700PTP-1 Pneumatic Test Pump

的详细介绍

Fluke 700PTP-1 Pneumatic Test Pump

Key features
Pump can be easily cleaned without disassembly
The vernier can be used as a stand-alone low pressure calibration source
Two pressure ports allowing simultaneous connection:
¼ in NPT female fitting for the reference gauge or pressure module
¼ in NPT female fitting for the unit under test
Adjustable stroke length can be set to limit the pressure per stroke

Fluke 700PTP-1 Pneumatic Test Pump

Pump Valve Assembly Cleaning Instructions
Occasionally, the 700PTP-1 may not work properly due to contamination of the internal valve assembly. Use the following procedure to clean the valve
assembly. If the procedure does not fix the problem, a repair kit (part number 2812587) may be ordered.
1. Using a small screwdriver, remove the 2 valve retention caps located on opposite sides of the pump below the pressure acuum switch.
2. Gently remove the spring and o-ring assembly. Take care when removing check valve as it contains several small components.Fluke 700PTP-1 Pneumatic Test Pump

Fluke 700PTP-1 Pneumatic Test Pump

3. Set aside the valve assemblies and clean out the valve body using a cotton swab soaked in isopropyl alcohol.
4. Repeat the process several times using a new swab until clean.
5. Operate the pump handles several times and recheck for contamination.
6. Clean the o-ring assembly and the o-ring on the retention caps with isopropyl alcohol and inspect the o-rings closely for any damage or excessive wear. Replacements are included in the repair kit.
7. Inspect the springs for wear or loss of tension. They should be approximately 8.6 mm long in the relaxed state. If shorter, they may provide sufficient sealing tension. Replace if needed.
8. Once all parts have been cleaned and inspected, reinstall the o-ring and spring assembly into the valve body.
9. Reinstall the retention caps and gently tighten each cap.
10. Seal the output port and operate the pump to at least 50 % of capacity.
11. Release the pressure and repeat several times to ensure that the o-rings seat properly.

Fluke 700PTP-1 Pneumatic Test Pump

Introduction
The Fluke-700PTP-1 Pneumatic Test Pump (hereafter called the “pump”) is a handheld device that develops precise pressure and vacuum. The pump
has the following specifications:
• Pressure to 40 bar (600 psi)
• Vacuum to -0.96 bar (-13.9 psi)
• Wetted materials: aluminum, silicon, neoprene, stainless steel,Buna-N
• Weight: 1.03 lb (467 g)
• Dimensions: length 8.7 in (220 mm), width 4.8 in (122 mm), depth 3.5 in (89 mm) 

Box Contents
• 700PTP-1 Pneumatic Test Pump
• 1/4 in NPT male to 1/4 in BSP female
• 1 m hose
• (2) 1/8 in NPT male quick connects
• 1/8 NPT female to 1/4 in BSP female
• Seal Kit
• Instruction Sheet

Fluke 700PTP-1 Pneumatic Test Pump

 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com