Description

Customised backplanes
MTL provides complete design and manufacturing service for customised backplanes. Customised backplanes give the vendors and users of process control and safety systems the opportunity to integrate MTL4000/4700/HART® modules directly into their system architecture. As there are no
hazardous-area circuits on the backplanes, customised versions can be produced without the need for IS certification, so simplifying design and lowering costs.
Universal custom backplanes
The 'universal' backplane allows a fast and economic approach to providing a custom interface. Where tight time schedules exist, the backplane can
be installed to allow the panel building and wiring to be completed. The customised adapter card can then be plugged in at any time up to integrated test.
Adapter cards
Adapter cards already exist for many of the DCS companies. In addition there is a range of general purpose cards that offer reduced wiring for use with specific MTL modules. These are also available in left- and right-hand versions to ease panel wiring.
Connections
All the bus powered backplanes have plug-in power connections. The MTL4700 backplanes also have the high integrity earth connections required for Zener barriers.
DCS vendors/systems supported:
ABB Automation
S100
INFI90
ABB August
SC300
Rockwell Automation
Bently-Nevada
Foxboro
IA FBM & FBM2xx
Moore Products
APACS
Quadlog
Honeywell
TDC
Plantscape
Honeywell-SMS
FSC
Simrad-Norge
Triconex
Tricon V9
Yokogawa
Centum XL, µXL
CS1000, CS3000, R3
Yokogawa Industrial Safety Systems

ProSafe

MTL Safety Barriers MTL4800 System Integration MTL4842


Specification

Maximum power requirements
 1.2W when fully populated
Interface bus connectors
 10-way ribbon socket
RS485 port
 2.5mm2 screw terminals
Mounting
 Supplied fitted with DIN-rail (T-or G-section)
Weight (excl. modules and accessories)
 330g
COMMON SPECIFICATION BPHM64 & HMU16
Power requirements, Vs
 21 to 35V dc through plug-in connectors
Mounting
 Supplied fitted with DIN-rail (T- or G- section) carrier
Interface bus connector
 10-way ribbon socket
RS485 port
 2.5mm2 screw terminals
HCU16 HART® CONNECTION UNIT
Accuracy (HCU16-P250 only)
 250Ω ±0.05%
Connectors
 2.5mm2 screw clamp terminals
 3 terminals per channel
 20-way flat cable (to BPHM64)
Weight
 383g
HCU16AO HART® CONNECTION UNIT WITH
FILTERS
Series impedance
 dc<2Ω
 HART® signal >240Ω
Connectors
 2.5mm2 removable screw clamp terminals
 2 terminals per channel in groups of 4 channels
 20-way flat cable (to BPHM64)
Weight
 768g
COMMON SPECIFICATION HCU16 & HCU16AO
Capacity
 16 channels
Isolation
 Channel to channel 50V dc
Mounting
 Supplied fitted with DIN-rail (T- or G- section) carrier

MTL Safety Barriers MTL4800 System Integration MTL4842

BPHM64 BACKPLANE

Capacity
1 x MTL4841 communications module
4 x MTL4842 HART® interface modules
NB: An MTL4841 module is needed for only one in every sixteen MTL4842 modules
Maximum power requirements
1.35W when equipped with:–
1 x MTL4841 communications module
4 x MTL4842 HART® interface modules
HART interface connectors
4 x DIN41651 20-way ribbon cables
(16 HART® signal connections + 4 common returns on each
cable. Connections to HART® signals via screw terminal interface
or custom backplane. Contact MTL for details.)
Weight (excl. modules and accessories)
 296g approx.
HMU16/32
Capacity
 1 x MTL4841 communications module
 2 x MTL4842 interface modules
Power requirements, Vs
 21 to 35V dc through plug in connectors
BPMH16/BPMH16U/BPSH16/BPSH16-32
BACKPLANES
Capacity
 16 x MTL4041A, MTL4041B, MTL4041P, MTL4046,
 MTL4046C, MTL4046P isolators (except BPSH16-32)
 16 x MTL4044 (BPSH16-32 only)
 1 x MTL4841 communications module
 1 x MTL4842 HART® interface module (2 x MTL4842 on
 BPSH16-32)
 NB: An MTL4841 module is needed for only one in every
 sixteen MTL4842 modules
Power requirements, Vs
 21 to 35V dc through plug-in connectors
Maximum power requirements
 1.35A (1.55A BPSH16-32)
Safe-area connectors
 BPMH16: Elco 8016 38-pin male connector
 BPMH16U: To customer's requirements
 BPSH16: 2.5mm2 screw terminals (2 terminals/module)
 BPSH16-32: 2.5mm2 screw terminals (4 terminals/module)
RS485 port
 2.5mm2 screw terminals
Accuracy
 BPSH16-32R: 250Ω ±0.05% conditioning resistor
Weight (excl. modules and accessories)
 350g approx.
ACCESSORIES
(for BPMH16/BPMH16U/BPSH16/BPSH16-32 backplanes)
ERK18 Earth rail kit
TSK18 Tagging strip kit
VMPH16 Vertical mounting plate
SMS01 Surface mounting kit for backplanes, pack of 40
DMK01 DIN-rail mounting kit (T- or G-section) for VMPH16 mounting plate, pack of 40 
16-way backplanes require 6
ELC38 Elco 8016, 38-way cable plug kit
FUS02 Fuse kit, protects MTL4841/4842, pack of 10
FUS16 Fuse kit, protects module positions 1 to 16, pack of 10
(for MTL4000)
CCH01 Hazardous-area crimp connector
SCC01 Hazardous-area screw-clamp connector
CRC01 Large crimps, pack of 100
CRC02 Small crimps, pack of 100
CRT01 Crimp tool for CRC01
CRT02 Crimp tool for CRC02
CRR01 Crimp removal tool for CRC01 and CRC02