MTL5523V–VL Solenoid/Alarm driver with voltage control
- Product Name:MTL5523V–VL Solenoid/Alarm driver with voltage control
- Product Number:MTL5523V
- Brand:MTL
- Views:352
- 
                    
                         
MTL5523V–VL Solenoid/Alarm driver with voltage control
的详细介绍Product overview
	MTL5523V–VL Solenoid/Alarm driver with voltage control 
	
 
	              MTL5523V – VL Solenoid/Alarm driver with voltage control 
 
	                
 
MTL5523V product specification as below
	MTL5523V–VL Solenoid/Alarm driver with voltage control 
With the MTLx523V/VL interface, an on/off device in a hazardous area can be controlled by a voltage signal in the safe area. It is suitable for driving loads such as solenoids. Line fault detection (LFD), which operates irrespective of the output state, is signalled by a safe-area solid-state switch which energises if a field line is open or short– circuited. Earth fault detection can be provided by connecting an MTL4220 earth leakage detector to terminal 3.
SPECIFICATION
	MTL5523V–VL Solenoid/Alarm driver with voltage control 
See also common specification
Number of channelsOne
Location of load
Zone 0, IIC, T4–6 hazardous area if suitably certified
Div. 1, Group A, hazardous location
Hazardous-area output (MTLx523V)
Minimum output voltage: 13.6V at 48mA
Maximum output voltage: 24V from 180Ω
Maximum off-state output voltage: 4V from 180Ω
Current limit: 48mA minimum
Hazardous-area output (MTLx523VL)
Minimum output voltage: 11.1V at 48mA
Maximum output voltage: 24V from 232Ω
Maximum off-state output voltage: 4V from 232Ω
Current limit: 48mA minimum
Output ripple
< 0.5% of maximum output, peak to peak
Control input
Suitable for 24V logic drive
Output turns on if > 18V applied across control input
Output turns off if < 5V applied across control input
Maximum control input voltage: 28V
Maximum control system output leakage current: 0.5mA
Response time
Output within 10% of final value within 100ms
Line fault detection (LFD)
Open or short circuit in field cabling energises solid state
line-fault signal.
LFD transistor is switched off, provided that the field circuit impedance is >
55Ω and < 4kΩ.
Line fault signal characteristics
Maximum off-state voltage: 35V
Maximum off-state leakage current: 10µA
Maximum on-state voltage drop: 2V
Maximum on-state current: 50mA
LED indicators
Green: power indication
Yellow: output status, on when output active
Red: LFD indication, on when line fault detected
Maximum current consumption
100mA at 24V dc
Power dissipation within unit
1.2W with typical solenoid valve, output on
2.0W worst case
Safety description (MTLx523V)
Vo=25V Io=147mA Po= 0.92W Um = 253V rms or dc
Safety description (MTLx523VL)
Vo=25V Io=108mA Po= 0.68W Um = 253V rms or dc
	
Other related models for 5523V as below for your reference.
	MTL5523V–VL Solenoid/Alarm driver with voltage control 
	MTL5018AC
	MTL5501-SR
	MTL5510
	MTL5510B
	MTL5511
	MTL5513 
	MTL5514
	MTL5514D
	MTL5516C
	MTL5517
	MTL5521
	MTL5522
	MTL5523
	MTL5523V – V
	MTL5524
	MTL5525
	MTL5526
	MTL5541
	MTL5541A
	MTL5541AS 
	MTL5541S
	MTL5544
	MTL5544A
	MTL5544AS
	MTL5544D
	MTL5544S
	MTL5546
	MTL5546Y
	MTL5549
	MTL5549Y
	MTL5573
	MTL5575
	MTL5576-RTD
	MTL5576-THC
	MTL5581
	MTL5582
	MTL5582B
	MTL5991 
	MTL5531
	MTL5532
	MTL5533
	MTL5561 
	MPA5500
	MTL5051
	MTL5053
	MTL5314
	MTL5599 
	MTL5523V–VL Solenoid/Alarm driver with voltage control 
	
If you have any other question about MTL5523V, please feel free to contact me here!
Contact details
	HONGKONG XIEYUAN TECH CO., LIMITED
	Telephone:86-027-85508558
Mobile :86-15871691193(Whatapp&Wechat is available)
	Skype:xyautomation
E-mail:sales1@hkxytech.com
	
 
     
     
                             
                             
                             
                             
                             
                             
                             
                             
                            