MTL4510 – MTL5510 SWITCH/ PROXIMITY DETECTOR INTERFACE

4-channel, digital input

The MTLx510 enables four solid-state outputs in the safe area to be controlled by up to four switches or proximity detectors located in a hazardous area. Each pair of output transistors shares a  common terminal and can switch +ve or –ve polarity signals. A range of module configurations is available (see Table 1) through the use of selector switches. When proximity detector modes are selected, LFD is enabled and the output switches to OFF if a line fault is detected.

MTL Safety Barriers Crouse-Hinds Switch/ Proximity Detector Interface MTL5510


Specification:
Number of channels
4, configured by switches
Location of switches
Zone 0, IIC, T6 hazardous  area Div 1, Group A hazardous location
Location of proximity detectors
Zone 0, IIC, T4-6 hazardous area if suitably certified Div 1, Group A, hazardous location
Hazardous-area inputs
Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR)
Voltage applied to sensor
7 to 9V dc from 1kΩ ±10%
Input/output characteristics 

Normal phase
Outputs closed if input > 2.1mA (< 2kΩ in input circuit) 

Outputs open if input < 1.2mA (> 10kΩ in input circuit)
Hysteresis: 200µA (650Ω) nominal

Line fault detection (LFD) (when selected)
User-selectable via switches on the side of the unit. Open-circuit alarm on if Iin < 50µA
Open-circuit alarm off if Iin > 250µA
Short-circuit alarm on if Rin < 100Ω Short-circuit alarm off if Rin  > 360Ω
Note: Resistors must be fitted when using the LFD facility with a contact input
500Ω to 1kΩ in series with switch 

20kΩ to 25kΩ in parallel with switch
MTL Safety Barriers Crouse-Hinds Switch/ Proximity Detector Interface MTL5510


 Mode options

MODE

o/p 1

o/p 2

o/p 3

o/p 4

i/p type

0

chA

chB

chC

chD

 

 

 

 

switch

1

chA rev.

chB

chC

chD

2

chA

chB rev.

chC

chD

3

chA

chB

chC rev.

chD

4

chA

chB

chC

chD rev.

5

chA rev.

chB

chC rev.

chD

6

chA

chB rev.

chC

chD rev.

7

chA rev.

chB rev.

chC rev.

chD rev.

8

chA

chB

chC

chD

 

 

 

prox. detector

+ LFD

9

chA rev.

chB

chC

chD

10

chA

chB rev.

chC

chD

11

chA

chB

chC rev.

chD

12

chA

chB

chC

chD rev.

13

chA rev.

chB

chC rev.

chD

14

chA

chB rev.

chC

chD rev.

15

chA rev.

chB rev.

chC rev.

chD rev.

MTL Safety Barriers Crouse-Hinds Switch/ Proximity Detector Interface MTL5510


Type

MTL4510 – MTL5510

MTL Safety Barriers Crouse-Hinds Switch/ Proximity Detector Interface MTL5510

 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd