MTL Safety Barrier MTL5516C Switch Proximity Detector Interface

  • Product Name:MTL Safety Barrier MTL5516C Switch Proximity Detector Interface
  • Product Number: MTL5516C
  • Brand:MTL
  • Views:69
你添加了1件商品 查看购物车
简单介绍
MTL Safety Barrier MTL5516C Switch Proximity Detector Interface MTL Safety Barrier MTL5516C Switch Proximity Detector Interface MTL Safety Barrier MTL5516C Switch Proximity Detector Interface

MTL Safety Barrier MTL5516C Switch Proximity Detector Interface

的详细介绍

MTL Safety Barrier MTL5516C Switch Proximity Detector Interface



MTL Safety Barrier MTL5516C Switch Proximity Detector Interface

MTL Safety Barrier MTL5516C Switch Proximity Detector Interface


Feature

The MTLx516/C enable two safe-area loads to be controlled by a switch or proximity detector  ocated in a hazardous-area. When selected, open or short circuit conditions in the field wiring are  etected by the linefault-detect (LFD) facility and also indicated on the top of the module.
Phase reversal for each channel is selected by a switch on the side of the module and output is provided by changeover relay contacts.

MTL Safety Barrier MTL5516C Switch Proximity Detector Interface


Specification

Number of channels
Two
Location of switches
Zone 0, IIC, T6 hazardous area
Div. 1, Group A hazardous location
Location of proximity detector
Zone 0, IIC, T4–6 hazardous area if suitably certified
Div. 1, Group A hazardous location
Hazardous-area inputs
Inputs conforming to BS EN60947–5–6:2001 standards for
proximity detectors (NAMUR)
Voltage applied to sensor
7 to 9V dc from 1kΩ ±10%
Input/output characteristics
Normal phase
Outputs closed if input > 2.1mA (< 2kΩ in input circuit)
Outputs open if input < 1.2mA (> 10kΩ in input circuit)
Hysteresis: 200µA (650Ω) nominal
Line fault detection (LFD) (when selected)
User-selectable via switches on the side of the unit. Line faults are
indicated by an LED for each channel. The channel output relay is
de-energised if an input line fault is detected.
Open-circuit alarm on if Iin < 50µA
Open-circuit alarm off if Iin > 250µA
Short-circuit alarm on if Rin < 100Ω
Short-circuit alarm off if Rin > 360Ω
Note: Resistors must be fitted when using the LFD facility with a contact input
500Ω to 1kΩ in series with switch
20kΩ to 25kΩ in parallel with switch
Safe-area output
Two single-pole relays with changeover contacts
Note: reactive loads must be adequately suppressed
Relay characteristics
MTL4516/C MTL5516C
Response time: 10ms maximum 10ms maximum
Contact rating
(Safe Area):
10W, 0.5A,
35V dc
250V ac, 2A, cosØ >0.7,
40V dc, 2A, resistive load
Contact rating
(Zone 2):
10W, 0.5A,
35V dc
35V, 2A, 100VA.
Maximum current consumption
35mA at 24V
Power dissipation within unit
0.84W at 24V
MTL Safety Barrier MTL5516C Switch Proximity Detector Interface

MTL Safety Barrier MTL5516C Switch Proximity Detector Interface

 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd