MTL5576-THC 2channel Temperature converter, THC safety barrier
- Product Name:MTL5576-THC 2channel Temperature converter, THC safety barrier
- Product Number:MTL5576-THC
- Brand:MTL
- Views:224
- 
                    
                         
MTL5576-THC 2channel Temperature converter, THC safety barrier
的详细介绍Product overview
	MTL5576-THC 2channel Temperature converter, THC safety barrier
	
 
	               MTL5576-THC  2channel Temperature converter, THC safety barrier
 
	                        
 
MTL5576-THC product specification as below
	MTL5576-THC 2channel Temperature converter, THC safety barrier
	MTL4576-THC –
MTL5576-THC TEMPERATURE CONVERTER mV/THC input, 2-channel
	The MTLx576–THC
converts low–level dc signals from temperature sensors mounted in a
hazardous–area into 4/20mA currents for driving safe–-area loads. Software
selectable features include linearisation for standard thermocouple types,
ranging, monitoring, testing and tagging. Configuration is carried out using a
personal computer. The hazardous–area connections include cold–junction compensation
and do not need to be ordered separately.
	SPECIFICATION
	MTL5576-THC 2channel Temperature converter, THC safety barrier
	See also
common specification
	Number
of channels
	Two
	Signal
source
	THC
types J, K, T, E, R, S, B or N to BS 60584 and XK
	mV input
	Location
of signal source
	Zone 0,
IIC, T4–6 hazardous area
	Division
1, Group A, hazardous location
	Input
signal range
	–75 to
+75mV
	Input
signal span
	3 to
150mV
	Cold
junction compensation
	Automatic
or selectable
	Cold
junction compensation error
	≤ 1.0°C
	Common
mode rejection
	120dB
for 240V at 50Hz or 60Hz
	Series
mode rejection
	40dB for
50Hz or 60Hz
	Calibration
accuracy (at 20°C)(includes hysteresis, non-linearity and repeatability)
	Input:
±15µV or ±0.05% of input value
	(whichever
is greater)
	Output:
±16µA
	Temperature
drift (typical)
	Input:
±0.003% of input value/°C
	Output:
±0.6µA/°C
	Safety
drive on sensor burnout
	Upscale,
downscale, or off
	Output
range
	4 to
20mA nominal into 300Ω max.
	Maximum
lead resistance
	300Ω
with safety drive on sensor failure enabled
	>10kΩ
with safety drive on sensor failure disabled
	Response
time
	Configurable
- 500 ms default
	(Accuracy
at 100/200ms - contact Eaton's MTL product line)
	LED
indicator
	Green:
power and status indication
	Yellow:
one provided for channel status
	Red:
alarm indication
	Power
requirement, Vs with 20mA signal
	60mA at
24V
	Power
dissipation within unit with 20mA signal
	1.4W at
24V
	Isolation
	Functional
isolation channel–channel for safe and hazardous–area
	circuits.
	Safety
description
	Refer to
certificate for parameters. Um=253V rms or dc
	Configurator
	A
personal computer running MTL PCS45 software with a
	PCL45USB
serial interface.
Other related models for MTL5500 range as below
MTL5576-THC 2channel Temperature converter, THC safety barrier
	
	MTL5018AC
	MTL5501-SR
	MTL5510
	MTL5510B
	MTL5511
	MTL5513 
	MTL5514
	MTL5514D
	MTL5516C
	MTL5517
	MTL5521
	MTL5522
	MTL5523
	MTL5523V – V
	MTL5524
	MTL5525
	MTL5526
	MTL5541
	MTL5541A
	MTL5541AS 
	MTL5541S
	MTL5544
	MTL5544A
	MTL5544AS
	MTL5544D
	MTL5544S
	MTL5546
	MTL5546Y
	MTL5549
	MTL5549Y
	MTL5573
	MTL5575
	MTL5576-RTD
	MTL5576-THC
	MTL5581
	MTL5582
	MTL5582B
	MTL5991 
	MTL5531
	MTL5532
	MTL5533
	MTL5561 
	MPA5500
	MTL5051
	MTL5053
	MTL5314
	MTL5599 
	MTL5576-THC 2channel Temperature converter, THC safety barrier
	
Contact details
	HONGKONG XIEYUAN TECH CO., LIMITED
	Telephone:86-027-85508558
Mobile :86-15871691193(Whatapp&Wechat is available)
	Skype:xyautomation
E-mail:sales1@hkxytech.com
	
 
     
     
                             
                             
                             
                             
                             
                             
                             
                             
                            