MTL5533 2channel vibration probe interface isolated barrier
- Product Name:MTL5533 2channel vibration probe interface isolated barrier
- Product Number:MTL5533
- Brand:MTL
- Views:212
- 
                    
                         
MTL5533 2channel vibration probe interface isolated barrier
的详细介绍Product overview
MTL5533 2channel vibration probe interface isolated barrier
	
MTL5533 2channel vibration probe interface isolated barrier
	           
 
MTL5533 product specification as below
	MTL5533 2channel vibration probe interface isolated barrier
	MTL5533 VIBRATION TRANSDUCER INTERFACE 2-channel
	The MTL5533 repeats signals from vibration sensors in a hazardous area, providing outputs for a monitoring system in the safe area. The interface is compatible with 3-wire eddy-current probes and accelerometers or 2-wire current sensors, the selection is made by switches on the side of the module.
SPECIFICATION
	MTL5533 2channel vibration probe interface isolated barrier
	See also common specification
	Number of channels
	Two
	Sensor type
	2- or 3-wire vibration transducer
	Location of signal source
	Zone 0, IIC, T4–6 hazardous area if suitably certified
	Div. 1, Group A hazardous location
	Hazardous-area input
	Input impedance
	(terminals 2 & 3, 5 & 6): 10kΩ
	Transducer supply current, 2-wire
	3.3mA (nom.) for 2-wire sensors, user selectable by switch
	Signal range
	Minimum –20V, maximum –0.5V
	DC transfer accuracy at 20°C
	<±50mV
	AC transfer accuracy at 20°C
	0Hz to 1kHz: ±1%
	1kHz to 10kHz: –5% to +1%
	10kHz to 20kHz: –10% to +1%
	Temperature coefficient
	±50ppm/°C (10 to 65°C)
	±100ppm/°C (–20 to 10°C)
	Voltage bandwidth
	–3dB at 47kHz (typical)
	Phase response
	<14µs, equivalent to:
	–1° at 200Hz
	–3° at 600Hz
	–5° at 1kHz
	–50° at 10kHz
	–100° at 20kHz
	Safe-area output impedance
	<20Ω
LED indicator
	Green: power indication
	Supply voltage
	20 to 35V dc
	Maximum current consumption (10mA transducer load/ch)
	130mA at 24V
	Maximum power dissipation within unit
	2.7W
	Safety description
	Terminals 3 to 1 and 6 to 4
	Uo=26.6V Io=94mA Po=0.66W Um = 253V rms or dc
	Terminals 3 to 2 and 6 to 5
	Non-energy-storing apparatus ≤1.5V, ≤0.1A and ≤25mW
MTL5533 2channel vibration probe interface isolated barrier
Other related model for MTL5500 range as below
	MTL5018AC
	MTL5501-SR
	MTL5510
	MTL5510B
	MTL5511
	MTL5513 
	MTL5514
	MTL5514D
	MTL5516C
	MTL5517
	MTL5521
	MTL5522
	MTL5523
	MTL5523V – V
	MTL5524
	MTL5525
	MTL5526
	MTL5541
	MTL5541A
	MTL5541AS 
	MTL5541S
	MTL5544
	MTL5544A
	MTL5544AS
	MTL5544D
	MTL5544S
	MTL5546
	MTL5546Y
	MTL5549
	MTL5549Y
	MTL5573
	MTL5575
	MTL5576-RTD
	MTL5576-THC
	MTL5581
	MTL5582
	MTL5582B
	MTL5991 
	MTL5531
	MTL5532
	MTL5533
	MTL5561 
	MPA5500
	MTL5051
	MTL5053
	MTL5314
	MTL5599 
	
If you have any other question about MTL5533, please feel free to contact me here!
Contact detail
	
	HONGKONG XIEYUAN TECH CO., LIMITED
	Telephone:86-027-85508558
Mobile :86-15871691193(Whatapp&Wechat is available)
	Skype:xyautomation
E-mail:sales1@hkxytech.com
 
     
     
                             
                             
                             
                             
                             
                             
                             
                             
                            