Current Location: Home> Product Class> MTL> MTL5500>

MTL5514D 1channel switch/prox input, dual output relay

  • Product Name:MTL5514D 1channel switch/prox input, dual output relay
  • Product Number:MTL5514D
  • Brand:MTL
  • Views:422
你添加了1件商品 查看购物车
简单介绍
MTL5514D 1channel switch/prox input, dual output relay MTL5514D 1channel switch/prox input, dual output relay MTL5514D 1channel switch/prox input, dual output relay

MTL5514D 1channel switch/prox input, dual output relay

的详细介绍

Product overview

MTL5514D 1channel switch/prox input, dual output relay


           MTL5514D 1channel switch/prox input, dual output relay

          

MTL5514D product specification as below for your reference.

MTL5514D 1channel switch/prox input, dual output relay

MTL4514D – MTL5514D SWITCH/ PROXIMITY DETECTOR INTERFACE 1-channel, dual output, LFD, phase reversal

The MTLx514D enables two safe–area loads to be controlled, through relays, by a proximity detector or switch located in a hazardous area. When selected, open or short circuit conditions in the field wiring are detected by the line fault detect (LFD) facility and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection.

SPECIFICATION

MTL5514D 1channel switch/prox input, dual output relay

Number of channelsOne

Location of switch

Zone 0, IIC, T6 hazardous area

Div.1, Group A, hazardous location

Location of proximity detector

Zone 0, IIC, T4–6 hazardous area, if suitably certified

Div.1, Group A, hazardous location

Hazardous–area inputs

Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR)

Voltage applied to sensor

7 to 9V dc from 1kΩ ±10%

Input/output characteristics

Normal phase

Outputs closed if input > 2.1mA (< 2kΩ in input circuit)

Outputs open if input < 1.2mA (> 10kΩ in input circuit)

Hysteresis: 200µA (650Ω) nominal

Line fault detection (LFD) (when selected)

User-selectable via switches on the side of the unit. Line faults are indicated by an LED. The channel output relays are de-energised if an input line-fault is detected

Open-circuit alarm on if Iin < 50µA

Open-circuit alarm off if Iin > 250µA

Short-circuit alarm on if Rin < 100Ω

Short-circuit alarm off if Rin > 360Ω

Note: Resistors must be fitted when using the LFD facility with a contact input 500Ω to 1kΩ in series with switch 20kΩ to 25kΩ in parallel with switch

Safe-area output

MTL4514D: two, single pole relays with normally-open contacts

MTL5514D: two, single pole relays with changeover contacts

Note: reactive loads must be adequately suppressed

LED indicators

Green: power indication

Yellow: channel status, on when output energised

Red: LFD indication, on when line fault detected

Maximum current consumption

29mA at 24V dc

Power dissipation within unit 0.7W at 24V

Safety description Uo=10.5V Io=14mA Po=37mW Um = 253V rms or dc



Other related models for MTL5500 range as below

MTL5514D 1channel switch/prox input, dual output relay

MTL5018AC

MTL5501-SR

MTL5510

MTL5510B

MTL5511

MTL5513 

MTL5514

MTL5514D

MTL5516C

MTL5517

MTL5521

MTL5522

MTL5523

MTL5523V – V

MTL5524

MTL5525

MTL5526

MTL5541

MTL5541A

MTL5541AS 

MTL5541S

MTL5544

MTL5544A

MTL5544AS

MTL5544D

MTL5544S

MTL5546

MTL5546Y

MTL5549

MTL5549Y

MTL5573

MTL5575

MTL5576-RTD

MTL5576-THC

MTL5581

MTL5582

MTL5582B

MTL5991 

MTL5531

MTL5532

MTL5533

MTL5561

MPA5500

MTL5051

MTL5053

MTL5314

MTL5599 

MTL5514D 1channel switch/prox input, dual output relay


If  you have any other question about MTL5514D, please feel free to send me an inquiry.

Contact details

HONGKONG XIEYUAN TECH CO., LIMITED

Telephone:86-027-85508558

Mobile :86-15871691193(Whatapp&Wechat is available)

Skype:xyautomation

E-mail:sales1@hkxytech.com


 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd