MTL5516C 2 channel DI with changeover relay output isolated barrier
- Product Name:MTL5516C 2 channel DI with changeover relay output isolated barrier
- Product Number:MTL5516C
- Brand:MTL
- Views:423
- 
                    
                         
MTL5516C 2 channel DI with changeover relay output isolated barrier
的详细介绍Product overview
	MTL5516C 2 channel DI with changeover relay output isolated barrier
	
MTL5516C 2 channel DI with changeover relay output isolated barrier
	                   
 
MTL5516C product specification as below for your reference.
	MTL5516C 2 channel DI with changeover relay output isolated barrier
	MTL4516/C – MTL5516C SWITCH/
PROXIMITY DETECTOR INTERFACE 2-channel, with line fault detection
	The MTLx516/C enable two
safe-area loads to be controlled by a switch or proximity detector located in a
hazardous-area. When selected, open or short circuit conditions in the field
wiring are detected by the linefault-detect (LFD) facility and also indicated
on the top of the module. Phase reversal for each channel is selected by a
switch on the side of the module and output is provided by changeover relay
contacts.
	SPECIFICATION
	MTL5516C 2 channel DI with changeover relay output isolated barrier
	Number of channels :Two 
	Location
of switches 
	Zone 0,
IIC, T6 hazardous area 
	Div. 1,
Group A hazardous 
	location
Location of proximity detector 
	Zone 0,
IIC, T4–6 hazardous area if suitably certified Div. 1, Group A hazardous
location Hazardous-area inputs 
	Inputs
conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR)
	Voltage
applied to sensor 
	7 to 9V
dc from 1kΩ ±10% 
	Input/output
characteristics 
	Normal
phase 
	Outputs
closed if input > 2.1mA (< 2kΩ in input circuit) 
	Outputs
open if input < 1.2mA (> 10kΩ in input circuit) 
	Hysteresis:
200µA (650Ω) nominal 
	Line
fault detection (LFD) (when selected) 
	User-selectable
via switches on the side of the unit. Line faults are indicated by an LED for
each channel. The channel output relay is de-energised if an input line fault
is detected. 
	Open-circuit
alarm on if Iin < 50µA 
	Open-circuit
alarm off if Iin > 250µA 
	Short-circuit
alarm on if Rin < 100Ω Short-circuit alarm off if Rin > 360Ω 
	Note:
Resistors must be fitted when using the LFD facility with a contact input 500Ω
to 1kΩ in series with switch 20kΩ to 25kΩ in parallel with switch
	Safe-area
output 
	Two
single-pole relays with changeover contacts Note: reactive loads must be
adequately suppressed
	Maximum
current consumption :35mA at 24V 
	Power
dissipation within unit: 0.84W at 24V
	LED
indicators 
	Green:
power indication Yellow: two: channel status, on when output energised Red:
two: LFD indication, on when line fault detected 
	Safety
description (each channel) 
	Uo=10.5V
Io=14mA Po=37mW Um = 253V rms or dc
	
Other related models for MTL5516C as below
	MTL5516C 2 channel DI with changeover relay output isolated barrier
	MTL5018AC
	MTL5501-SR
	MTL5510
	MTL5510B
	MTL5511
	MTL5513 
	MTL5514
	MTL5514D
	MTL5516C
	MTL5517
	MTL5521
	MTL5522
	MTL5523
	MTL5523V – V
	MTL5524
	MTL5525
	MTL5526
	MTL5541
	MTL5541A
	MTL5541AS 
	MTL5541S
	MTL5544
	MTL5544A
	MTL5544AS
	MTL5544D
	MTL5544S
	MTL5546
	MTL5546Y
	MTL5549
	MTL5549Y
	MTL5573
	MTL5575
	MTL5576-RTD
	MTL5576-THC
	MTL5581
	MTL5582
	MTL5582B
	MTL5991 
	MTL5531
	MTL5532
	MTL5533
	MTL5561 
	MPA5500
	MTL5051
	MTL5053
	MTL5314
	MTL5599 
	MTL5516C 2 channel DI with changeover relay output isolated barrier
	
Contact detail
	HONGKONG XIEYUAN TECH CO., LIMITED
	Telephone:86-027-85508558
Mobile :86-15871691193(Whatapp&Wechat is available)
	Skype:xyautomation
E-mail:sales1@hkxytech.com
	
 
     
     
                             
                             
                             
                             
                             
                             
                             
                             
                            